Application

Vacuum pumps for laboratory vacuum and glove boxes

In the laboratory, vacuum works on many instruments: on the rotary evaporator, the desiccator, filtration, the freeze dryer, the mass spectrometer and the glove box, in which air-sensitive substances stay under protective gas. For this Pfeiffer Vacuum describes quiet, clean vacuum for mass spectrometry, freeze drying, glove boxes and filtration, supplied individually at the instrument or centrally. Below you can see how the application works, what vacuum the manufacturers name and which of their series are intended for it – 131 models from 6 manufacturers.

Compare 131 modelsHow it works

  • 131Models
  • 13Series
  • 6Manufacturers
  • approx. 45 dBNoise of the HiScroll in the laboratory (Pfeiffer Vacuum)
ABCDEFG

Touch the points: each part of the system explains itself.

In short

Laboratory vacuum and glove boxes: the key facts

  • QuietFor the HiScroll Pfeiffer Vacuum names about 45 dB – quiet, clean vacuum for mass spectrometry, freeze drying, glove boxes and filtration.
  • Glove boxFor glove boxes Edwards describes: remove the residual air, then fill with nitrogen or argon; Pfeiffer Vacuum names clean vacuum for air-sensitive work (HiScroll), Becker gas circulation in glove boxes.
  • Chemistry laboratoryFor chemistry, pharmacy and chemistry laboratories Leybold lists TRIVAC B (BCS PFPE), NEO D and SCROLLVAC; Atlas Copco names DVS and GVS A for general and chemical laboratories.
  • UniversitiesEdwards names RV and E2M for laboratories and universities in chemistry, biology, physics and geology.
ABCDEFG
  • Air and gas (vacuum)
  • Exhaust

Operating principle

How it works: Laboratory vacuum and glove boxes

The drawing shows the basic principle in section. The systems and pumps of the individual manufacturers differ in detail.

  1. EvacuationThe pump draws the air out of the instrument or glove box; for glove boxes Edwards describes the removal of the residual air.
  2. WorkingUnder vacuum, samples are evaporated, filtered, dried or measured – Pfeiffer Vacuum names mass spectrometry, freeze drying, glove boxes and filtration.
  3. VentingThe instrument is vented; according to Edwards, the glove box is filled with nitrogen or argon so that the sample does not come into contact with air.

Vacuum and sizing

Laboratory vacuum and glove boxes: how much vacuum is needed

What the manufacturers say about pressure, pumping speed and sizing.

Which vacuum

The pressure required depends on the instrument and the solvent; as a figure Pfeiffer Vacuum names the noise: HiScroll about 45 dB.

Which pumping speed

Pfeiffer Vacuum distinguishes between supply individually at the instrument and central supply; Atlas Copco names GVS A for the central laboratory.

What determines the design

Cleanliness and noise (Pfeiffer Vacuum), compatibility with chemicals – for chemistry laboratories Leybold lists TRIVAC B in the BCS PFPE version – and, for the glove box, the protective gas (Edwards: nitrogen or argon).

What the manufacturers point out

Besides laboratory vacuum, Becker names gas circulation in glove boxes; Busch names COBRA for glove boxes and isolators; Edwards names rotary vane and scroll pumps for glove boxes.

Technology

Laboratory vacuum and glove boxes: the vacuum pumps the manufacturers name

Listed are the series the manufacturer itself names for this application. ā€œShow only ā€¦ā€ sets the filter of the product overview.

Product overview

Laboratory vacuum and glove boxes: all 131 models compared

Use the filters on the left to narrow the selection – by manufacturer, technology and the models’ key figures, for 50 or 60 Hz.

Atlas Copco DVS series 10 models

DVS 5Pumping speed 5 m³/h 50 Hz6 m³/h 60 HzUltimate pressure 120 mbarRated motor power 0.12 kW 50 Hz0.15 kW 60 HzVariants 3
DVS 8Pumping speed 8 m³/h 50 Hz9 m³/h 60 HzUltimate pressure 150 mbarRated motor power 0.25 kW 50 Hz0.3 kW 60 HzVariants 3
DVS 16Pumping speed 16 m³/h 50 Hz19 m³/h 60 HzUltimate pressure 120 mbarRated motor power 0.75 kW 50 Hz0.9 kW 60 HzVariants 3
DVS 25Pumping speed 25 m³/h 50 Hz29 m³/h 60 HzUltimate pressure 120 mbarRated motor power 0.75 kW 50 Hz0.9 kW 60 HzVariants 3
DVS 40Pumping speed 40 m³/h 50 Hz48 m³/h 60 HzUltimate pressure 120 mbarRated motor power 1.3 kW 50 Hz1.5 kW 60 HzVariants 3
DVS 60Pumping speed 60 m³/h 50 Hz70 m³/h 60 HzUltimate pressure 150 mbarRated motor power 1.5 kW 50 Hz1.8 kW 60 HzVariants 3
DVS 80Pumping speed 80 m³/h 50 Hz90 m³/h 60 HzUltimate pressure 150 mbarRated motor power 2.2 kW 50 Hz3 kW 60 HzVariants 3
DVS 100Pumping speed 100 m³/h 50 Hz115 m³/h 60 HzUltimate pressure 150 mbarRated motor power 3.4 kW 50 Hz4 kW 60 HzVariants 3
DVS 140Pumping speed 130 m³/h 50 Hz150 m³/h 60 HzUltimate pressure 150 – 200 mbarRated motor power 3.4 kW 50 Hz4 kW 60 HzVariants 3
DVS 12Pumping speed 14 m³/h 60 HzUltimate pressure 120 mbarRated motor power 0.45 kW 60 HzVariants 1

Atlas Copco GVS series 9 models

GVS 16 APumping speed 16 m³/h 50 Hz19 m³/h 60 HzUltimate pressure 0.5 mbarRated motor power 0.75 kW 50 Hz0.9 kW 60 HzVariants 5
GVS 25 APumping speed 25 m³/h 50 Hz29 m³/h 60 HzUltimate pressure 0.5 mbarRated motor power 0.75 kW 50 Hz0.9 kW 60 HzVariants 4
GVS 40 APumping speed 44 m³/h 50 Hz53 m³/h 60 HzUltimate pressure 0.5 mbarRated motor power 1.1 kW 50 Hz1.5 kW 60 HzVariants 6
GVS 60 APumping speed 59 m³/h 50 Hz71 m³/h 60 HzUltimate pressure 0.5 – 1 mbarRated motor power 1.5 kW 50 Hz1.8 kW 60 HzVariants 6
GVS 100 APumping speed 98 m³/h 50 Hz117 m³/h 60 HzUltimate pressure 0.5 mbarRated motor power 2.2 kW 50 Hz3.5 kW 60 HzVariants 5
GVS 150 APumping speed 151 m³/h 50 Hz181 m³/h 60 HzUltimate pressure 0.1 – 4 mbarRated motor power 3.3 kW 50 Hz3.7 kW 60 HzVariants 3
GVS 220 APumping speed 200 m³/h 50 Hz240 m³/h 60 HzUltimate pressure 0.1 mbarRated motor power 4.5 kW 50 Hz5.1 kW 60 HzVariants 5
GVS 300 APumping speed 280 m³/h 50 Hz340 m³/h 60 HzUltimate pressure 0.1 – 1 mbarRated motor power 5.5 kW 50 Hz6.3 kW 60 HzVariants 6
GVS 630 APumping speed 700 m³/h 50 Hz840 m³/h 60 HzUltimate pressure 0.1 mbarRated motor power 15 kW 50 Hz18.5 kW 60 HzVariants 5

Becker BCV series 7 models

BCV 100Pumping speed 100 m³/h 50 Hz120 m³/h 60 HzUltimate pressure 50 mbarRated motor power 2.2 – 3 kW 50 Hz2.2 – 3 kW 60 HzVariants 4
BCV 150Pumping speed 150 m³/h 50 Hz180 m³/h 60 HzUltimate pressure 100 mbarRated motor power 3 – 4 kW 50 Hz3 – 4 kW 60 HzVariants 4
BCV 300Pumping speed 275 m³/h 50 Hz325 m³/h 60 HzUltimate pressure 150 mbarRated motor power 5.5 – 7.5 kW 50 Hz5.5 – 7.5 kW 60 HzVariants 4
BCV 400Pumping speed 400 m³/h 50 Hz470 m³/h 60 HzUltimate pressure 200 mbarRated motor power 9.2 kW 50 Hz11.8 kW 60 HzVariants 5
BCV 400 FDPumping speed 400 m³/h 50 Hz470 m³/h 60 HzUltimate pressure 200 mbarRated motor power 7.5 kW 50 Hz9.2 kW 60 HzVariants 4

Busch COBRA Industry series 36 models

Edwards E2M series 9 models

Edwards RV series 8 models

Leybold NEO D series 5 models

Leybold SCROLLVAC series 5 models

Leybold TRIVAC series 20 models

Pfeiffer Vacuum ACP series 4 models

Pfeiffer Vacuum DuoVane series 12 models

Pfeiffer Vacuum HiScroll series 4 models

Pfeiffer Vacuum SmartVane series 2 models

Model comparison

Models a manufacturer no longer carries in its current range are listed in its ā€œOutdated modelsā€ section.

Industries

Laboratory vacuum and glove boxes: where the manufacturers name it

The manufacturers list these uses on their own pages.

Research, laboratory and analytics

Pfeiffer Vacuum, Edwards and Busch list laboratory vacuum under research and analytics: Pfeiffer Vacuum with HiScroll, ACP, DuoVane and SmartVane, Edwards with RV and E2M for universities, Busch with COBRA for glove boxes and isolators.

Chemicals

Pfeiffer Vacuum names laboratory vacuum for chemistry too; Leybold lists TRIVAC B (BCS PFPE), NEO D and SCROLLVAC for chemistry, pharmacy and chemistry laboratories.

Pharmaceuticals and biotechnology

Pfeiffer Vacuum lists laboratory vacuum for pharmaceuticals and biotechnology, with ACP, DuoVane, HiScroll and SmartVane.

Medical and healthcare

Pfeiffer Vacuum names laboratory vacuum for medicine; Becker names laboratory vacuum in an FAQ on medical and environmental technology with its claw vacuum pumps, without describing it in more detail.

Mechanical engineering and manufacturing

In general mechanical engineering Becker names gas circulation in glove boxes.

Environmental and wastewater

Becker names laboratory vacuum in an FAQ on medical and environmental technology, without describing it in more detail.

Frequently asked questions

Laboratory vacuum and glove boxes: frequently asked questions

Which vacuum pump for the laboratory?

For laboratory vacuum Pfeiffer Vacuum names HiScroll, ACP, DuoVane and SmartVane – quiet and clean for mass spectrometry, freeze drying, glove boxes and filtration. Leybold lists TRIVAC B, NEO D and SCROLLVAC for chemistry laboratories, Edwards RV and E2M for laboratories and universities, Atlas Copco DVS and GVS A for general and chemical laboratories, Busch COBRA for glove boxes, Becker BCV.

Which vacuum pump for a glove box?

Pfeiffer Vacuum names the HiScroll for clean vacuum in air-sensitive work. Edwards names rotary vane and scroll pumps for glove boxes, Leybold the NEO D, Busch COBRA for glove boxes and isolators. Becker names gas circulation in glove boxes.

How does a glove box work with vacuum?

According to Edwards, the residual air is removed from the box and the box is then filled with nitrogen or argon; this keeps air-sensitive substances from coming into contact with oxygen or moisture. The vacuum pump evacuates the box or its airlock; Pfeiffer Vacuum names clean vacuum for this.

Oil-free or oil-lubricated in the laboratory?

Both are named. Pfeiffer Vacuum places the dry HiScroll at about 45 dB alongside the oil-lubricated DuoVane and SmartVane and the multi-stage ACP; Leybold lists the oil-lubricated TRIVAC B and NEO D alongside the dry SCROLLVAC; Edwards names rotary vane and scroll pumps for glove boxes; Atlas Copco the dry DVS and the oil-lubricated GVS A.

How loud is a laboratory vacuum pump?

For the HiScroll Pfeiffer Vacuum states about 45 dB and describes quiet vacuum as a requirement in the laboratory.

Which vacuum pump for the chemistry laboratory?

For chemistry, pharmacy and chemistry laboratories Leybold lists TRIVAC B in the BCS PFPE version, NEO D and SCROLLVAC. Atlas Copco names DVS and GVS A for general and chemical laboratories, Pfeiffer Vacuum ACP, DuoVane, HiScroll and SmartVane also for chemistry.

How much vacuum does a rotary evaporator need?

In physical terms: the lower the pressure, the lower the boiling temperature of the solvent; the pressure required therefore depends on the solvent and the bath temperature.

Which vacuum pump for universities and research laboratories?

Edwards names RV and E2M for laboratories and universities in chemistry, biology, physics and geology. Pfeiffer Vacuum names HiScroll, ACP, DuoVane and SmartVane, Busch COBRA for glove boxes and isolators in the laboratory.

Which vacuum pump for freeze drying and mass spectrometers in the laboratory?

Pfeiffer Vacuum names both under laboratory vacuum and, for them, HiScroll, ACP, DuoVane and SmartVane – quiet and clean, individually at the instrument or central.

A single pump or a central vacuum system?

A central system in a room of its own keeps noise and heat away from production and matches its output to the demand. Central vacuum systems are planned and built by Eugen Theis Vakuum, a company of the Ehrler & Beck group – more under Central Vacuum.

Does Ehrler & Beck also supply spare parts and service?

Yes. Ehrler & Beck offers original spare parts and accessories as well as maintenance and repair.

Which pump suits your process?

Tell us the application, the medium and the volume – we advise you on selection, spare parts and service.

Send an enquirySpare parts and accessoriesService