BCV 400 FD 3Ph 400 V 50 Hz / 460, 400 V 60 Hz, UL/CSA

The Becker BCV 400 FD is a dry, contact-free compressing claw vacuum pump with a pumping speed of 400 m³/h at 50 Hz (470 m³/h at 60 Hz) and a vacuum down to 200 mbar absolute. The exhaust air is oil-free and maintenance is minimal. Ehrler & Beck advises on selection, accessories and service.

Request a quote for this product Read more

  • Pumping speed 400 m³/h 50 Hz 470 m³/h 60 Hz
  • Ultimate pressure 200 mbar
  • Rated motor power 7.5 kW 50 Hz 9.2 kW 60 Hz
Available variants
Motor variant Motor order number
3Ph 400 V 50 Hz / 460, 400 V 60 Hz, UL/CSA (selected) 43089202304088GW
3Ph 200/346 V 50 Hz / 200/346, 220/380, 400 V 60 Hz, UL/CSA 43089225304088GW
3Ph 288/500 V 50 Hz / 332/575 V 60 Hz, UL/CSA 43089257304088GW
3Ph 230/400 V 50 Hz / 230/460, 400, 208 V 60 Hz, UL/CSA 43189207304088GW

Becker BCV 400 FD – dry claw vacuum pump

The BCV 400 FD delivers 400 m³/h at 50 Hz and 470 m³/h at 60 Hz and reaches a vacuum of 200 mbar absolute. Installed motor power 7.5 kW at 50 Hz and 9.2 kW at 60 Hz, sound pressure level 73 / 75 dB(A). The pump weighs 258 kg without motor and 339–346 kg with motor (Becker catalogue 2026). Dimensions: 1248.5 × 520 × 527 mm (Becker catalogue 2026). Suction connection G 3" (or NPT 3"), exhaust connection G 2" (or NPT 2").

Contact-free claw principle

Two claw-shaped rotors rotate in opposite directions and without contact in the compression chamber. As a result the pump works without oil in the pumping chamber, with little wear and little maintenance; the exhaust air is oil-free.

Low overall height (FD)

The FD version is particularly low in height; according to Becker, the small space requirement makes it easier to integrate into existing systems.

Further versions

  • BCV 400: standard version with integrated filtration

Advice and service

Ehrler & Beck supports you in selecting the right size and motor version, supplies accessories and spare parts and carries out maintenance and repair.