BCV 100Pumping speed 100 m³/hUltimate pressure 50 mbar
BCV 150 3Ph 220/380, 230/400, 240/415 V 50 Hz / 460 V 60 Hz, UL/CSA
Die Becker BCV 150 ist eine trockene, berührungslos verdichtende Klauen-Vakuumpumpe mit 150 m³/h Pumping speed bei 50 Hz (180 m³/h bei 60 Hz) und einem Vakuum bis 100 mbar absolut. Die Abluft ist oil-free, die Wartung minimal. Ehrler & Beck advises on selection, accessories and service.
Request a quote for this product Read more
- Pumping speed 150 m³/h 50 Hz 180 m³/h 60 Hz
- Ultimate pressure 100 mbar
- Rated motor power 3 kW 50 Hz 3 kW 60 Hz
| Motor variant | Motor order number |
|---|---|
| 3Ph 220/380, 230/400, 240/415 V 50 Hz / 460 V 60 Hz, UL/CSA (selected) | 42489201300088GW |
| 3Ph 200/346 V 50 Hz / 200/346, 220/380, 400 V 60 Hz, UL/CSA | 42489253300088GW |
| 3Ph 290/500 V 50 Hz / 332/575 V 60 Hz, UL/CSA | 42689257300088GW |
| 3Ph 230/400 V 50 Hz / 230/460 V 60 Hz, UL/CSA | 42789207300088GW |
Becker BCV 150 – trockene Klauen-Vakuumpumpe
Die BCV 150 fördert 150 m³/h bei 50 Hz und 180 m³/h bei 60 Hz und erreicht ein Vakuum von 100 mbar absolut. Installierte Motor power 3,0–4,0 kW bei 50 Hz und 3,0–4,0 kW bei 60 Hz, Sound pressure level 67 / 71 dB(A). Die Pumpe wiegt without motor 156 kg, with motor 190–201 kg (Becker-Katalog 2026). Dimensions: 805–847 × 553 × 579,5 mm (Länge motorabhängig). Suction connection G 2 1/2", Abluftanschluss G 1 1/2".Berührungsloses Klauenprinzip
Zwei klauenförmige Rotoren drehen gegenläufig und berührungslos im Verdichtungsraum. Dadurch arbeitet die Pumpe ohne Öl im Schöpfraum, verschleißarm und mit geringem Wartungsaufwand; die Abluft ist oil-free.Filterung und Wartung
Transparente Filterabdeckungen zeigen Verschmutzungen sofort an; die Filter lassen sich einfach prüfen. Die robuste Bauweise ist auf lange Laufzeiten auch unter anspruchsvollen Bedingungen ausgelegt.Weitere Versions
- VARIAIR BCV 150: Version mit VARIAIR-Frequency inverter
Advice and service
Ehrler & Beck unterstützt bei der Auswahl der passenden Baugröße und Motorausführung, liefert Accessories und Spare parts und übernimmt Wartung und Reparatur.| Pumping speed 50Hz | 150 |
|---|---|
| Pumping speed 60Hz | 180 |
| Ultimate pressure | 100 |
| Rated motor power 50Hz | 3 |
| Rated motor power 60Hz | 3 |
| Motor efficiency class | IE3 |
| Weight | 201 |
| Length | 80.5 |
| Width | 55.3 |
| Height | 57.95 |
| Inlet connection flange | G 2 1/2" |
| Outlet connection flange | G 1 1/2" |
| Noise level | 67 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Further technical data
| Motor | Data |
|---|---|
| Motor order number | 42489201300088GW |
| Pump types according to Becker | BCV 150 BCP 100 (PD) +0.8 bar [11.6 PSIG] |
| Phases | 3~ (three-phase) |
| 50 Hz | 3,0 kW (4,0 hp) · Δ220/Y380 V · IE3 · 2890 min⁻¹ · 10,3/5,95 A 3,0 kW (4,0 hp) · Δ230/Y400 V · IE3 · 2900 min⁻¹ · 10,1/5,78 A 3,0 kW (4,0 hp) · Δ240/Y415 V · IE3 · 2905 min⁻¹ · 9,86/5,7 A |
| 60 Hz | 3,0 kW (4,0 hp) · Y460 V · IE3 · 3515 min⁻¹ · 5,01 A |
| 60 Hz, zusätzliches Typenschild | 3,6 kW (4,8 hp) · Δ230/Y400 V · IE1 · 3453 min⁻¹ · 11,6/6,69 A 3,6 kW (4,8 hp) · Δ265/Y460 V · IE2 · 3505 min⁻¹ · 10,2/5,87 A |
| Version | CE • UL • CSA • CC IP55 • ISO F • PTC |
| Motor length M1 | 316,0 mm |
| Total length L1 with pump | 805,0 mm |
| Motor weight | 33,0 kg |
| Motor data according to | Becker Motor Specifications for Pumps and Blowers (09/2026), Position 9-03 |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Klauen-Vakuumpumpe, trocken und berührungslos verdichtend, air-cooled |
| Pumping speed 50 Hz / 60 Hz | 150 / 180 m³/h |
| Vakuum (absolut) | 100 mbar |
| Installed motor power 50 Hz / 60 Hz | 3,0–4,0 / 3,0–4,0 kW |
| Sound pressure level 50 Hz / 60 Hz | 67 / 71 dB(A) |
| Weight without motor | 156 kg |
| Weight with motor | 190–201 kg (Becker-Katalog 2026, motorabhängig) |
| Dimensions | 805–847 × 553 × 579,5 mm (Länge motorabhängig) |
| Suction connection / Abluftanschluss | G 2 1/2" / G 1 1/2" |
| Becker data sheet | Stand 2024-10-31 |
| Version | Beschreibung |
|---|---|
| VARIAIR BCV 150 | Version mit VARIAIR-Frequency inverter |