Application
Vacuum pumps for sterilisation
In sterilisation, vacuum removes the air from the steriliser so that steam, ethylene oxide or hydrogen peroxide reach every part of the load ā according to Leybold, it ensures good distribution of the sterilant and dries the load at the end of the cycle. Edwards names air removal in steam, EtO, H2O2, plasma and e-beam processes. Below you can see how the application works, what vacuum the manufacturers name and which of their series are intended for it ā 230 models from 6 manufacturers.
Compare 230 modelsHow it works
- 230Models
- 18Series
- 6Manufacturers
- down to 0.1 hPaPump-down cycles in H2O2 sterilisation (Pfeiffer Vacuum)
Touch the points: each part of the system explains itself.
In short
Sterilisation: the key facts
- Removing airAccording to Leybold, the vacuum removes the air so that the sterilant spreads well, and dries the load at the end of the cycle. Atlas Copco names air removal in the autoclave.
- ProcessesEdwards names air removal in steam, EtO, H2O2, plasma and e-beam processes, Atlas Copco vacuum cycles in EtO sterilisation, Busch EtO and steam sterilisation with COBRA and DOLPHIN.
- Cold sterilisationLeybold names H2O2 sterilisation for heat-sensitive products such as endoscopes with TRIVAC and NEO D. Pfeiffer Vacuum describes H2O2 sterilisation in pump-down cycles down to 0.1 hPa and lists ACP, DuoVane and HiScroll for it.
- Steam and waterFor autoclaves Elmo Rietschle names L series liquid ring vacuum pumps for humid environments. For steam sterilisation Leybold names VARODRY, a dry screw pump that needs no water, instead of a liquid ring pump, Pfeiffer Vacuum vapour-tolerant rotary vane vacuum pumps.
Operating principle
How it works: Sterilisation
The drawing shows the basic principle in section. The systems and pumps of the individual manufacturers differ in detail.
- EvacuationThe vacuum pump removes the air from the chamber (Atlas Copco, Leybold) so that the sterilant reaches the entire load.
- SterilisationSteam, EtO or H2O2 act on the load ā with EtO (Atlas Copco) and H2O2 (Pfeiffer Vacuum) in several vacuum cycles.
- DryingAt the end of the cycle the vacuum dries the load (Leybold); the steam condenses in the condenser.
Vacuum and sizing
Sterilisation: how much vacuum is needed
What the manufacturers say about pressure, pumping speed and sizing.
What vacuum
For H2O2 sterilisation Pfeiffer Vacuum names pump-down cycles down to 0.1 hPa.
What pumping speed
The pumping speed depends on the chamber volume and the cycle time. For sterilisation Pfeiffer Vacuum names vapour-tolerant rotary vane vacuum pumps and multi-stage Roots pumps.
Steam and humidity
Steam is what puts strain on the pump: Elmo Rietschle names liquid ring vacuum pumps for humid environments, Pfeiffer Vacuum vapour-tolerant rotary vane pumps, Leybold VARODRY as a dry screw pump that needs no water, Edwards chemical dry pumps, claw and liquid ring vacuum pumps.
Cycles
Atlas Copco names vacuum cycles in EtO sterilisation, Pfeiffer Vacuum pump-down cycles with H2O2, Leybold drying at the end of the cycle ā the vacuum is built up several times per batch.
Technology
Sterilisation: the vacuum pumps the manufacturers name
Listed are the series the manufacturer itself names for this application. āShow only ā¦ā sets the filter of the product overview.
Liquid ring vacuum pumps
136 models Ā· 20ā16,160 m³/h
Oil-lubricated rotary vane vacuum pumps
50 models Ā· 0.75ā255 m³/h
Screw vacuum pumps
36 models Ā· 70ā4,652 m³/h
Roots vacuum pumps
4 models Ā· 14ā88 m³/h
Scroll vacuum pumps
4 models Ā· 6.1ā43 m³/h
Product overview
Sterilisation: all 230 models compared
Use the filters on the left to narrow the selection ā by manufacturer, technology and the modelsā key figures, for 50 or 60 Hz.
Atlas Copco AWC series 9 models
Atlas Copco GVD series 13 models
Atlas Copco LRP VSD+ series 3 models
LRP 700 VSD+Pumping speed 740 m³/h 50 Hz740 m³/h 60 HzUltimate pressure 25 mbarRated motor power 18.5 kW 50 Hz18.5 kW 60 HzVariants 10Busch COBRA Industry series 36 models
Busch DOLPHIN series 70 models
Edwards LR1A series 12 models
Edwards LR1C series 9 models
Edwards LR1D series 12 models
Elmo Rietschle L-BL2 series 7 models
Elmo Rietschle L-BV2 series 4 models
Elmo Rietschle L-BV3 series 1 model
Elmo Rietschle L-BV5 series 5 models
Elmo Rietschle L-BV7 series 4 models
Leybold NEO D series 5 models
Leybold TRIVAC series 20 models
Pfeiffer Vacuum ACP series 4 models
Pfeiffer Vacuum DuoVane series 12 models
Pfeiffer Vacuum HiScroll series 4 models
No model matches these filters.
Atlas Copco AWC series 9 models
Atlas Copco GVD series 13 models
Atlas Copco LRP VSD+ series 3 models
Busch COBRA Industry series 36 models
Busch DOLPHIN series 70 models
Edwards LR1A series 12 models
Edwards LR1C series 9 models
Edwards LR1D series 12 models
Elmo Rietschle L-BL2 series 7 models
Elmo Rietschle L-BV2 series 4 models
Elmo Rietschle L-BV3 series 1 model
Elmo Rietschle L-BV5 series 5 models
Elmo Rietschle L-BV7 series 4 models
Leybold NEO D series 5 models
Leybold TRIVAC series 20 models
Pfeiffer Vacuum ACP series 4 models
Pfeiffer Vacuum DuoVane series 12 models
Pfeiffer Vacuum HiScroll series 4 models
Models a manufacturer no longer carries in its current range are listed in its āOutdated modelsā section.
Industries
Sterilisation: where the manufacturers name it
The manufacturers list these uses on their own pages.
Medical and healthcare
For medicine and hospitals, sterilisation is named by Atlas Copco (air removal in the autoclave, EtO cycles; GVD, LRP VSD+, AWC), Busch (EtO and steam sterilisation with COBRA and DOLPHIN), Elmo Rietschle (L series for autoclaves), Leybold (TRIVAC and NEO D, H2O2 for endoscopes) and Pfeiffer Vacuum (H2O2 down to 0.1 hPa with ACP, DuoVane, HiScroll).
Mechanical engineering and manufacturing
Edwards names sterilisation among industrial applications: air removal in steam, EtO, H2O2, plasma and e-beam processes with chemical dry pumps, claw vacuum pumps and liquid ring vacuum pumps (LR1A, LR1C, LR1D).
Frequently asked questions
Sterilisation: frequently asked questions
Why does an autoclave need a vacuum pump?
Because the air has to leave the chamber before the steam can act: Atlas Copco names air removal in the autoclave, Leybold the good distribution of the sterilant through the vacuum. At the end of the cycle the vacuum dries the load (Leybold).
How does steam sterilisation with vacuum work?
The pump evacuates the chamber, then the steam flows in and reaches every part of the load (Leybold: good distribution of the sterilant). After the exposure time the chamber is evacuated again, and the vacuum dries the load (Leybold). Busch names steam sterilisation with COBRA and DOLPHIN, Elmo Rietschle autoclaves with L series liquid ring vacuum pumps.
What is H2O2 sterilisation (cold sterilisation)?
A sterilisation with hydrogen peroxide at low temperature. Leybold names it for heat-sensitive products such as endoscopes, Pfeiffer Vacuum describes it as pump-down cycles down to 0.1 hPa. Edwards also lists plasma and e-beam processes.
Which vacuum pump for sterilisers?
Leybold names TRIVAC and NEO D (and VARODRY for steam), Pfeiffer Vacuum ACP, DuoVane and HiScroll, Busch COBRA and DOLPHIN, Elmo Rietschle the L series, Edwards LR1A, LR1C and LR1D as well as chemical dry pumps and claw vacuum pumps, Atlas Copco GVD, LRP VSD+ and AWC.
How much vacuum does sterilisation need?
For H2O2 sterilisation Pfeiffer Vacuum names pump-down cycles down to 0.1 hPa. The pressure required depends on the process.
Liquid ring or dry pump for steam sterilisation?
Both are named. Elmo Rietschle names L series liquid ring vacuum pumps for the humid environment of autoclaves, Edwards liquid ring pumps alongside chemical dry pumps and claw pumps. For steam sterilisation Leybold names VARODRY, a dry screw pump that needs no water, instead of a liquid ring pump; Pfeiffer Vacuum names vapour-tolerant rotary vane vacuum pumps.
Which vacuum pump for H2O2 sterilisation?
Pfeiffer Vacuum lists ACP, DuoVane and HiScroll for it, Leybold TRIVAC and NEO D. Pfeiffer Vacuum names pump-down cycles down to 0.1 hPa.
What happens in EtO sterilisation with vacuum?
Atlas Copco names vacuum cycles in EtO sterilisation. In these the chamber is evacuated, the ethylene oxide is admitted and then pumped out again. Busch names EtO sterilisation with COBRA and DOLPHIN, Edwards air removal in the EtO process.
How are sterile goods dried after sterilisation?
With vacuum: according to Leybold, it dries the load at the end of the cycle. The residual steam is pumped off and condenses in the condenser.
Which vacuum pump for heat-sensitive instruments such as endoscopes?
For heat-sensitive products such as endoscopes, Leybold names H2O2 sterilisation (cold sterilisation) with TRIVAC and NEO D. Pfeiffer Vacuum lists ACP, DuoVane and HiScroll for H2O2 sterilisation.
A single pump or a central vacuum system?
A central system in a room of its own keeps noise and heat away from production and matches its output to the demand. Central vacuum systems are planned and built by Eugen Theis Vakuum, a company of the Ehrler & Beck group ā more under Central Vacuum.
Does Ehrler & Beck also supply spare parts and service?
Yes. Ehrler & Beck offers original spare parts and accessories as well as maintenance and repair.
Which pump suits your process?
Tell us the application, the medium and the volume ā we advise you on selection, spare parts and service.