GVD 0.7Pumping speed 0.75 m³/hUltimate pressure 3 × 10-3 mbar
GVD 85 3Ph 220-240/380-415 V 50 Hz, 230/460 V 60 Hz
The Atlas Copco GVD 85 is a two-stage, oil-sealed rotary vane vacuum pump with a volume flow of 79 m³/h at 50 Hz and an ultimate pressure of 3 × 10⁻³ mbar without gas ballast. Robust, quiet and designed for high water vapour loads. Ehrler & Beck supplies it with accessories and service.
Request a quote for this product Read more
- Pumping speed 79 m³/h 50 Hz 95 m³/h 60 Hz
- Ultimate pressure 3 × 10-3 mbar
- Rated motor power 2.2 kW 50 Hz 2.6 kW 60 Hz
| Variant | Part number |
|---|---|
| 3Ph 220-240/380-415 V 50 Hz, 230/460 V 60 Hz (selected) | 1625213812 |
Atlas Copco GVD 85 – two-stage rotary vane pump for industry and fore vacuum
The GVD 85 delivers 79 m³/h at 50 Hz and 95 m³/h at 60 Hz and reaches 3 × 10⁻³ mbar without gas ballast. The motor delivers 2.2 kW (60 Hz: 2.6 kW). Dimensions 902 × 244 × 405 mm (L × W × H), weight 117 kg, inlet DN 40 ISO-KF, outlet DN 25 ISO-KF. Atlas Copco marks the performance data as preliminary.Pressurised lubrication and suck-back protection
The proven pressurised lubrication system prevents oil starvation even at high gas loads. When the pump is switched off under vacuum, protective devices prevent oil and air from being sucked back into the vacuum system. A Roots pump can be mounted on the central inlet port if required.Applications of the range
Atlas Copco lists the evacuation, drying and filling of refrigeration and air conditioning systems, vacuum drying and distillation, backing pumps for high vacuum applications, vacuum processes in metallurgy, thin-film coating, freeze drying, transformer and cable drying as well as insulating oil treatment, and the evacuation of cryogenic vessels.Versions
Ehrler & Beck lists the GVD 85 under part number 1625213812 for 3Ph 220-240/380-415 V 50 Hz, 230/460 V 60 Hz.Features of the GVD range
- Two-stage and oil-sealed: ultimate vacuum down into the 10⁻³ mbar range at high volume flows
- Pressurised oil circuit for reliable lubrication even at high gas loads
- Spring-loaded distributor valve as suck-back protection for oil and air on switch-off
- Controlled gas ballast for high water vapour loads
- Industrial roller bearings on the drive shaft, full-height oil sight glass, easily replaceable oil filter
- Central inlet port for easy mounting of a Roots pump (booster)
| Pumping speed 50Hz | 79 |
|---|---|
| Pumping speed 60Hz | 95 |
| Ultimate pressure | 3 × 10-3 |
| Rated motor power 50Hz | 2.2 |
| Rated motor power 60Hz | 2.6 |
| Weight | 117 |
| Length | 90.2 |
| Width | 24.4 |
| Height | 40.5 |
| Inlet connection flange | DN 40 ISO-KF |
| Outlet connection flange | DN 25 ISO-KF |
| Noise level | 58 dB(A) |
| Cooling method | Air cooling |
| Oil type | Vacuum Vane Fluid 68 |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Two-stage, oil-sealed rotary vane vacuum pump, direct drive |
| Volume flow 50 Hz / 60 Hz | 79 / 95 m³/h |
| Nominal pumping speed 50 Hz / 60 Hz | 92 / 110 m³/h |
| Ultimate pressure without gas ballast | 3 × 10⁻³ mbar |
| Ultimate pressure with gas ballast (setting 1 / 2) | 6 × 10⁻³ mbar / 2 × 10⁻² mbar |
| Water vapour | 732 / 878 g/h (50 / 60 Hz), water vapour tolerance 25 mbar |
| Motor power 50 Hz / 60 Hz | 2.2 / 2.6 kW |
| Mains connection | 3Ph 220-240/380-415 V 50 Hz, 230/460 V 60 Hz |
| Speed 50 Hz / 60 Hz | 1458 / 1760 rpm |
| Sound pressure level | 58 dB(A) (with gas ballast 60 dB(A)) |
| Cooling | Air |
| Oil filling | 4.0 to 5.2 l Vacuum Vane Fluid 68 |
| Ambient temperature | 10 to 40 °C |
| Dimensions L × W × H | 902 × 244 × 405 mm |
| Weight | 117 kg |
| Inlet / outlet | DN 40 ISO-KF / DN 25 ISO-KF |
| Data as of | preliminary data according to the Atlas Copco data sheet (08/2023) |