ACP 15Pumping speed 14 m³/hUltimate pressure 0.05 mbar
ACP 90 Version for corrosive gases, G version, single-phase motor, purge gas connection R 1/4"
The Pfeiffer ACP 90 is a dry multi-stage Roots pump with a maximum pumping speed of 88 m³/h and an ultimate pressure of 0.03 mbar. Ehrler & Beck advises on selection and service.
Request a quote for this product Read more
- Pumping speed 88 m³/h 50 Hz
- Ultimate pressure 0.03 mbar
| Variant | Part number |
|---|---|
| Version for corrosive gases, G version, three-phase, low voltage, purge gas connection R 1/4" | V9GABSBZRR02 |
| Version for corrosive gases, G version, three-phase, high voltage, purge gas connection R 1/4" | V9GABSCZRR02 |
| SD version, single-phase motor, manual gas ballast | V9SABSAZMR02 |
| SD version, three-phase, low voltage, manual gas ballast | V9SABSBZMR02 |
| Version for corrosive gases, G version, single-phase motor, purge gas connection R 1/4" (selected) | V9GABSAZRR02 |
| SD version, three-phase, high voltage, manual gas ballast | V9SABSCZMR02 |
Pfeiffer ACP 90 – dry multi-stage Roots pump
The Pfeiffer ACP 90 is a dry multi-stage Roots pump. The maximum pumping speed is 88 m³/h, the ultimate pressure 0.03 mbar.Features
- Reliable: virtually maintenance-free, high-quality bearings, long service life
- Efficient: low power consumption, IE5 permanent-magnet motor
- Powerful: high pumping speed at high pressures, for large volumes and frequent pump-down, high water vapour tolerance
Typical applications
Pfeiffer lists: Automotive and transport (heat treatment, leak detection and EoL testing, space research and others); Batteries (leak detection and EoL testing (master), vacuum drying, recycling); Chemistry (freeze drying, lyophilisation, leak detection); Dairy products (cheese production – vacuum chambers for cheese, cheese production – cheese towers, butter production); Hydrogen economy (leak detection and EoL testing (master)); Medical (H2O2 sterilisation, medical accelerators); Metallurgy (3D printing, heat treatment); Pharmaceuticals and biotechnology (freeze drying, lyophilisation, leak detection); Power generation (green power generation); R&D (freeze drying, lyophilisation, high-energy physics, photonics research and others); Refrigeration and air conditioning (leak detection and EoL testing, vacuum drying); Semiconductors (inspection & metrology, ion implantation, lithography and others); Industrial gases (liquefaction, insulation vacuum, gas transport and others); Thin-film coating (optical coating, decorative coating, laboratory coating).Accessories
- Dust filter
- External silencer
- Shut-off valve
- Preventive maintenance packages
- Corrosive gas version
Versions of the Pfeiffer ACP 90
The 6 versions differ in motor, voltage and equipment; order numbers and descriptions from the Busch Group shop.Advice and service
Ehrler & Beck advises on selection, accessories and service.| Pumping speed 50Hz | 88 |
|---|---|
| Ultimate pressure | 0.03 |
| Weight | 75 |
| Length | 67.1 |
| Width | 31.9 |
| Height | 34.3 |
| Inlet connection flange | DN 40 ISO-KF |
| Outlet connection flange | DN 40 ISO-KF |
| Noise level | 65 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Additional technical data
| Technical data | Value |
|---|---|
| Max. pumping speed | 88 m³/h |
| Ultimate pressure without dilution gas | 3 · 10⁻² mbar |
| Ultimate pressure with gas ballast | 1.6 · 10⁻¹ mbar |
| Max. continuous inlet pressure | 1013 mbar |
| Max. water vapour tolerance | 2400 g/h (depending on the version) |
| Single-phase supply | 200 – 240 V AC |
| Two-phase supply | 200 – 240 V AC |
| Three-phase supply | 380 – 480 V AC |
| Power consumption at ultimate pressure | 1.3 kW |
| Max. power consumption | 2 kW |
| Sound pressure level at ultimate pressure | < 65 dB(A) |
| Cooling | Air cooling |
| Max. leak rate | < 5 · 10⁻⁶ mbar·l/s |
| Dimensions (L × W × H) | 671 × 319 × 343 mm |
| Weight | 75 kg |
| Connection flange, inlet | DN 40 ISO-KF |
| Connection flange, outlet | DN 40 ISO-KF |