DRYVAC DV 200Pumping speed 210 m³/hUltimate pressure 0.05 mbarDRYVAC DV 1200 3Ph 380-460 V 50/60 Hz, DV 1200-i, LEYBONOL LVO 210, triple purge gas module, I/O interface
The Leybold DRYVAC DV 1200 is a dry-compressing, water-cooled screw vacuum pump with 1250 m³/h maximum pumping speed and < 5 × 10⁻³ mbar ultimate pressure – supplied on a baseplate with castors, adjustable feet and enclosure. Ehrler & Beck supplies the DRYVAC DV 1200 in three variants with matching accessories and service.
Request a quote for this product Read more
- Pumping speed 1,250 m³/h 50 Hz 1,250 m³/h 60 Hz
- Ultimate pressure 5 × 10-3 mbar
- Rated motor power 30 kW 50 Hz 30 kW 60 Hz
| Variant | Part number |
|---|---|
| 3Ph 380-460 V 50/60 Hz, LEYBONOL LVO 210, Profibus | 112120V17-1 |
| 3Ph 380-460 V 50/60 Hz, DV 1200-i, LEYBONOL LVO 210, triple purge gas module, I/O interface (selected) | 112120V50-2 |
| 3Ph 380-460 V 50/60 Hz, DV 1200-i, LEYBONOL LVO 410, triple purge gas module, I/O interface | 112120V40-2 |
Leybold DRYVAC DV 1200 – high pumping capacity as a ready-to-connect unit
The DRYVAC DV 1200 achieves a maximum pumping speed of 1250 m³/h and an ultimate pressure of < 5 × 10⁻³ mbar. With a rated power of 30 kW, the power consumption at ultimate pressure is 13.8 kW. According to Leybold, all DV 1200 come on a baseplate with castors, adjustable feet and an enclosure and include a cooling water unit with water distribution, pressure reducer and overpressure safety valve. Dimensions 1339 × 705 × 985 mm, weight around 1400 kg, connections DN 100 ISO-K (inlet) and DN 100 ISO-K (exhaust), cooling water requirement 15 l/min, noise level with silencer 67 dB(A). Water vapour tolerance 60 mbar, water vapour capacity 50 kg/h.Versions with integrated controller (-i)
The i versions add a built-in controller with touchscreen and user interface to the DRYVAC for plug-&-play operation and configuration; as interfaces Leybold lists 24 V I/O, Profibus and Ethernet/IP.Typical applications
Metallurgy and furnace construction, coating, solar, evacuation of large chambers and load locks – wherever high pumping speed down into the medium vacuum range is needed.Variants of the DRYVAC DV 1200
The DRYVAC DV 1200 is available from Ehrler & Beck in three variants (part numbers 112120V17-1, 112120V50-2, 112120V40-2). The rated power is 30 kW at 380–460 V (50/60 Hz) for all variants, the weight around 1400 kg. Versions with LEYBONOL LVO 210 and LEYBONOL LVO 410 are available.Features of the DRYVAC series
- Oil-free pumping chamber: dry screw technology without oil backstreaming into the process
- For the harshest applications: hermetically sealed, several purge gas options, flushable
- Plug & Play: integrated frequency converter with sensors for exhaust pressure, motor and cooling water temperature, RS485 and fieldbus options
- Energy-efficient: patented rotor design and blow-off valves reduce power consumption
- Compact and water-cooled: according to Leybold significantly smaller than comparable pumps, cooling channels designed to prevent clogging
- Combinable: with RUVAC Roots pumps to form pump systems
| Pumping speed 50Hz | 1,250 |
|---|---|
| Pumping speed 60Hz | 1,250 |
| Ultimate pressure | 5 × 10-3 |
| Rated motor power 50Hz | 30 |
| Rated motor power 60Hz | 30 |
| Weight | 1,400 |
| Length | 133.9 |
| Width | 67.7 |
| Height | 110.5 |
| Inlet connection flange | DN 100 ISO-K |
| Outlet connection flange | DN 100 ISO-K |
| Noise level | 65 dB(A) |
| Cooling method | Water cooling |
| Oil type | LEYBONOL LVO 210, LEYBONOL LVO 410 |
Additional technical data
| Technical data | Value |
|---|---|
| Max. pumping speed (without gas ballast) | 1250 m³/h |
| Ultimate pressure without gas ballast | < 5 × 10⁻³ mbar |
| Water vapour tolerance | 60 mbar (with purge gas and gas ballast) |
| Water vapour capacity | 50 kg/h |
| Max. permissible inlet pressure | 1050 mbar |
| Rated power | 30 kW |
| Power consumption at ultimate pressure | 14 kW |
| Rated current at 400 V | 62 A |
| Mains voltage | 380-460 V ± 10 %, 50/60 Hz, 3-phase |
| Frequency converter | on the pump |
| Lubricant | LEYBONOL LVO 210 (synthetic oil), filling quantity 2.4 l |
| Equipment | Triple purge gas module, I/O interface |
| Inlet connection | DN 100 ISO-K |
| Exhaust connection | DN 100 ISO-K |
| Cooling | Water / air |
| Cooling water flow, nominal | 15 l/min |
| Cooling water temperature | 5 to 35 °C |
| Cooling water connection | G 1/2" |
| Purge gas connection | Quick connect D10 |
| Noise level | 65 dB(A) with silencer, at ultimate pressure (DIN EN ISO 2151) |
| IP protection class | IP 20 |
| Permissible ambient temperature | 5 to 40 °C |
| Relative humidity | 90 %, non-condensing |
| Installation altitude, max. | 2000 m above sea level |
| Product name | Part number |
|---|---|
| Plug screw M 16 x 1.5 (oil filler plug) | ES20127105 |
| Gasket for plug screw (oil filler plug) | ES23955165 |
| Filter cartridge for purge gas pressure reducer | E110000850 |
| Air filter for gas ballast valve | E110000980 |
| Pressure reducing cartridge for cooling water unit | E6519936 |
| LEYBONOL LVO 210, 5 litres | L21005 |
| LEYBONOL LVO 210, 208 litres | L21099 |
| LEYBONOL LVO 410 (PFPE), 1 litre | L41001 |
| Product name | Part number |
|---|---|
| Silencer DN 100 ISO-K for DRYVAC 1200/1600 | 119001 |
| Serviceable silencer DN 100 ISO-K | 119004V |
| Gas ballast kit DRYVAC 24 V, electro-pneumatic | 112005A17 |
| Set of nozzles for DRYVAC purge gas | 112005A30 |
| Permanent inlet purge kit DRYVAC | 112005A32 |
| Floor mount for DRYVAC DV 1200 / DV 1600 | 503637V001 |
| Harting plug for DV 1200 / DV 1600 | 112005A20 |
| External display (LCD operator panel) | 112005A80 |
| PROFINET module | 112005A75 |
| EtherCAT module | 112005A76 |
| Ethernet module (dual port) | 112005A72 |