TRIVAC D 90 L 3Ph 220/230/380/400 V 50 Hz

Part number: 1019090V00 Series: TRIVAC series Manufacturer: Leybold Technology: Oil-lubricated rotary vane vacuum pumps

The Leybold TRIVAC D 90 L is the largest size in the new TRIVAC L series: an air-cooled, two-stage rotary vane vacuum pump with a pumping speed of 79 m³/h at 50 Hz (95 m³/h at 60 Hz), an ultimate pressure of 3 × 10⁻³ mbar and DN 40 ISO-KF connections. IP 55, gas ballast with two positions and a water vapour capacity of 1464 g/h recommend it for metallurgy, coating, crystal pulling and pump systems with Roots pumps. Ehrler & Beck supplies the Leybold TRIVAC D 90 L in three variants, as well as spare parts and accessories.

Request a quote for this product Read more

  • Pumping speed 79 m³/h 50 Hz 95 m³/h 60 Hz
  • Ultimate pressure 3 × 10-3 mbar
  • Rated motor power 2.2 kW 50 Hz
Available variants
Variant Part number
3Ph 220/230/380/400 V 50 Hz (selected) 1019090V00
3Ph 220/230/380/400/415 V 50 Hz / 230/460 V 60 Hz 15190090V04CJL
3Ph 200 V 50 Hz / 200/380 V 60 Hz 1019090V02

TRIVAC D 90 L – the most powerful TRIVAC L

The Leybold TRIVAC D 90 L is Leybold's 90 m³/h version for higher pumping speed requirements: 79 m³/h at 50 Hz and 95 m³/h at 60 Hz (nominal pumping speed 92 m³/h), ultimate total pressure 3 × 10⁻³ mbar without gas ballast. As applications of the TRIVAC L, Leybold names, among others, metallurgical plants and industrial furnaces, large-area and industrial coating, crystal pulling (sapphire, SiC) for semiconductor and solar materials, oil degassing and the manufacture of LNG cryogenic tanks.

Design and function

The TRIVAC L is Leybold's new generation of air-cooled, two-stage rotary vane vacuum pumps. The patented oil casing reduces heat dissipation to the surroundings, lowers the oil temperature and extends the oil service life; a sight glass allows the oil condition to be checked daily. According to Leybold, the gas ballast offers improved water vapour tolerance for humid processes: ultimate total pressure 6 × 10⁻³ mbar (position 1) / 2 × 10⁻² mbar (position 2), water vapour tolerance 25 mbar, water vapour capacity 1464 g/h (50 Hz) / 1757 g/h (60 Hz). The pump is designed to protection class IP 55, the inlet and outlet are DN 40 ISO-KF, and the outlet can be oriented vertically or horizontally. The standard filling is mineral oil LEYBONOL LVO 130 (3.6 / 4.8 l), the noise level is 58 / 60 dB(A) (without / with gas ballast position 1).

Motor options and systems

Leybold offers the large TRIVAC L models in the motor versions EU/CN (50 Hz regions), EU/US (wide-range version), JP/KR (Japan, Korea, Taiwan) and without motor. With the Roots adapter, the pump can be combined compactly with Roots pumps RUVAC WA(U), WS(U) and WH(U) to form pump systems.

Variants of the TRIVAC D 90 L

The TRIVAC D 90 L is available from Ehrler & Beck in three variants (part numbers 1019090V00, 15190090V04CJL, 1019090V02). The rated motor power ranges from 2.2 to 3 kW (50 Hz), the weight is 96 kg. Voltage, phase and all further data of the individual variants can be found in the variant selection and under Technical data.

Features and benefits

  • For humid processes: Gas ballast with two positions and improved water vapour tolerance
  • Suitable for industrial use: Air cooling with optimised thermal design, protection class IP 55
  • Worldwide motor options: EU/CN, EU/US, JP/KR or without motor
  • Low operating costs: Energy-efficient motors, low power consumption, simplified maintenance
  • Simple system integration: Adjustable outlet flange and Roots adapter
  • Simple daily check: Sight glass for the oil condition
Go to Top