The impellers of FPZ blowers are made of aluminum alloy and are dynamically balanced. All standard FPZ blowers are supplied with built-in in-outlet silencers, which can then be modified to suit various deployment configurations.
MS Blower = One impeller, single stage
MD fan = One impeller, two-stage
TS blower = double impeller, single-stage
TD fan = double impeller, two-stage
In addition to the standard side channel blowers, FPZ has also developed special configurations that allow the machine to adapt to the most diverse industries that require the use of a blower.
MD blower
Single wheel - two-stage
Integral motor design versions, aluminum construction, capacity up to 473 m³ / h (50 Hz) / 570 m³ / h (60 Hz), ambient temperature from -15 to + 40 ° C
Two-pole electric motors, three-phase asynchronous, insulation class F - suitable for the tropics and protection class IP55.
Printing Applications:
Maximum flow up to 570 m³ / h Maximum pressure up to 750 mbar
Vacuum applications:
Maximum flow up to 570 m³ / h Maximum pressure up to 500 mbar
MS blower
Single wheel - single stage
Integrated motor design versions, aluminum construction, capacity up to 1022 m³ / h (50 Hz) / 1234 m³ / h (60 Hz), ambient temperature from -15 to + 40 ° C
Two-pole electric motors, single-phase and three-phase asynchronous, insulation class F-suitable for the tropics.
Printing Applications:
Maximum flow up to 1234 m³ / h, Maximum pressure up to 500 mbar
Vacuum applications:
Maximum flow up to 1234 m³ / h, Maximum pressure up to 375 mbar
TD blower
Double impeller - two-stage
Integrated motor design versions, aluminum construction, capacity up to 1007 m³ / h (50 Hz) / 1216 m³ / h (60 Hz), ambient temperature from -15 to + 40 ° C
Two-pole electric motors, single-phase and three-phase asynchronous, insulation class F - Tropicalized and IP55 protection.
Printing Applications:
Maximum flow up to 1216 m³ / h. Maximum pressure up to 650 mbar
Vacuum applications:
Maximum flow up to 1216 m³ / h. Maximum pressure up to 500 mbar
TS blower
Double impeller - single stage
Integral motor design versions, aluminum construction, capacity up to 1985 m³ / h (50 Hz) / 2395 m³ / h (60 Hz), ambient temperature from -15 to + 40 ° C
Two-pole electric motors, three-phase asynchronous, insulation class F - suitable for the tropics and protection class IP55.
Printing Applications:
Maximum flow up to 2395 m³ / h Maximum pressure up to 450 mbar
Vacuum applications:
Maximum flow up to 2395 m³ / h Maximum pressure up to 350 mbar
FPZ MS series
Models (50 / 60 Hz) | flow rate - m³/min | Pressure difference - vacuum - mbar | Pressure difference - pressure - mbar |
---|---|---|---|
K03 MS | 74 / 89 | 120 / 120 | 130 / 120 |
K04 MS | 137 / 166 | 140-225 / 120-250 | 140-250 / 120-250 |
K05-MS | 219 / 265 | 130-240 / 100-275 | 130-300 / 100-350 |
K06-MS | 304 / 366 | 180-270 / 150-325 | 180-340 / 150-220 |
K07-MS | 414 / 499 | 130-325 / 100-375 | 130-400 / 100-375 |
K08 MS | 536 / 647 | 125-350 / 100-375 | 125-450 / 100-450 |
K09 MS | 663 / 800 | 130-350 / 85-375 | 130-450 / 85-400 |
K10 MS | 782 / 944 | 160-350 / 115-375 | 160-500 / 115-500 |
K11 MS | 915 / 1105 | 175-350 / 130-350 | 175-500 / 130-500 |
K12 MS | 1022 / 1234 | 150-325 / 100-350 | 150-425 / 100-375 |
K75-MS | 477 / 576 | 150-250 / 100-300 | 150-325 / 100-300 |
FPZ MD series
Models (50 / 60 Hz) | flow rate - m³/min | Pressure difference - vacuum - mbar | Pressure difference - pressure - mbar |
---|---|---|---|
K07R-MD | 181 / 218 | 275-450 / 215-450 | 275-650 / 215-650 |
K08E-MD | 236 / 285 | 250-450 / 180-450 | 250-650 / 180-650 |
K09-MD | 310 / 374 | 285-475 / 200-475 | 285-725 / 200-725 |
K10-MD | 386 / 466 | 340-500 / 260-500 | 340-750 / 260-700 |
K11-MD | 430 / 519 | 250-500 / 175-500 | 250-750 / 175-750 |
K12-MD | 472 / 570 | 225-450 / 200-450 | 225-650 / 200-500 |
FPZ TS series
Models (50 / 60 Hz) | flow rate - m³/min | Pressure difference - vacuum - mbar | Pressure difference - pressure - mbar |
---|---|---|---|
K05-TS | 409 / 493 | 115-225 / 90-210 | 115-250 / 90-210 |
K06-TS | 562 / 679 | 130-250 / 100-250 | 130-300 / 100-275 |
K07-TS | 827 / 998 | 150-300 / 110-300 | 150-350 / 110-300 |
K08-TS | 1006 / 1214 | 100-325 / 60-325 | 100-380 / 60-325 |
K09-TS | 1325 / 1599 | 145-325 / 110-275 | 145-360 / 110-275 |
K10-TS | 1539 / 1857 | 160-275 / 125-260 | 160-275 / 125-260 |
K11-TS | 1764 / 2129 | 100-275 / 105-220 | 100-275 / 105-220 |
K12-TS | 1985 / 2395 | 150-200 / 140 | 150-200 / 140 |
FPZ TD series
Models (50 / 60 Hz) | flow rate - m³/min | Pressure difference - vacuum - mbar | Pressure difference - pressure - mbar |
---|---|---|---|
K04-TD | 139 / 168 | 175-275 / 140-300 | 175-400 / 140-350 |
K05-TD | 215 / 259 | 240-400 / 210-400 | 240-475 / 210-425 |
K06-TD | 312 / 376 | 275-400 / 225-400 | 275-550 / 225-525 |
K07-TD | 416 / 502 | 325-425 / 275-450 | 325-575 / 275-650 |
K08-TD | 518 / 625 | 235-450 / 180-475 | 235-550 / 180-490 |
K09-TD | 657 / 793 | 300-450 / 240-475 | 300-650 / 240-650 |
K10-TD | 804 / 970 | 325-500 / 275-500 | 325-600 / 275-525 |
K11-TD | 903 / 1089 | 235-475 / 160-400 | 235-475 / 160-400 |
K12-TD | 1007 / 1216 | 250-475 / 275-375 | 250-475 / 275-375 |