RUVAC WSU 2001 3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; PFPE LEYBONOL LVO 400, H version with ACE damper, 100 Hz operation possible

The Leybold RUVAC WSU 2001 is an air-cooled Roots vacuum pump with a hermetically sealed canned motor and integrated pressure equalisation line: 2050 m³/h nominal pumping speed at 50 Hz, 1850 m³/h maximum effective pumping speed and 7.5 kW motor power. Ehrler & Beck supplies the RUVAC WSU 2001 in 15 variants with matching accessories, spare parts and service.

Request a quote for this product Read more

  • Pumping speed 1,850 m³/h 50 Hz 2,100 m³/h 60 Hz
  • Ultimate pressure 0.04 mbar
  • Rated motor power 7.5 kW 50 Hz 8.5 kW 60 Hz
Available variants
Variant Part number
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Mineral oil LEYBONOL LVO 130 11753
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Mineral oil LEYBONOL LVO 130, TE version (CE) 11753TE
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Ester oil LEYBONOL LVO 210, 100 Hz operation possible 15096
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Ester oil LEYBONOL LVO 210, 100 Hz operation possible, TE version (CE) 15096TE
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Ester oil LEYBONOL LVO 210, 100 Hz operation possible, horizontal pumping direction 167026
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Ester oil LEYBONOL LVO 210, 100 Hz operation possible, horizontal pumping direction, TE version (CE) 167026TE
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Ester oil LEYBONOL LVO 210, 100 Hz operation possible, horizontal pumping direction 167056
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Mineral oil LEYBONOL LVO 130, H version with ACE damper 11853
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Mineral oil LEYBONOL LVO 130, H version with ACE damper, TE version (CE) 11853TE
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Mineral oil LEYBONOL LVO 130, H version with ACE damper, ATE version 11853ATE
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Ester oil LEYBONOL LVO 210, H version with ACE damper 167044
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; PFPE LEYBONOL LVO 400, H version with ACE damper 167129V
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; PFPE LEYBONOL LVO 400, H version with ACE damper, 100 Hz operation possible (selected) 155066
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; Supplied without oil, H version with ACE damper, vertical pumping direction, TE version (CE) 167042TE
3Ph 200/230/400 V 50 Hz, 200-208/265/460 V 60 Hz; water-cooled motor, TE version (CE) 167052TE

Leybold RUVAC WSU 2001 – Roots pump with canned motor and 2050 m³/h nominal pumping speed

The RUVAC WSU 2001 is the top model of the canned-motor series with pressure equalisation line: 2050 m³/h nominal pumping speed, start at atmospheric pressure and 7.5 kW motor power at 50 Hz. No other size offers as many versions – H versions with ACE damper, 100 Hz versions, pumps for horizontal pumping direction and a version with a water-cooled motor. The nominal pumping speed is 2050 m³/h at 50 Hz and 2460 m³/h at 60 Hz, the maximum effective pumping speed 1850 and 2100 m³/h respectively. The pump measures 1042 × 638 × 530 mm, weighs 465 kg and is connected via DN 160 ISO-K; the noise level is below 72 dB(A).

Typical applications

The RUVAC WS/WSU work as boosters in front of an oil-sealed or dry backing pump. Leybold recommends the canned-motor series for applications requiring a high pumping speed between 10⁻² and 10⁻⁴ mbar, for processes in which neither air may enter nor pumped medium escape, and for the extraction or transfer of high-purity gases. Typical applications of the RUVAC series are heat treatment and furnace construction, metallurgy, large-area coating, load-lock chambers and crystal pulling systems for the semiconductor and solar industries.

Variants of the RUVAC WSU 2001

The RUVAC WSU 2001 is available from Ehrler & Beck in 15 variants (part numbers 11753, 11753TE, 15096, 15096TE, 167026, 167026TE, 167056, 11853, 11853TE, 11853ATE, 167044, 167129V, 155066, 167042TE, 167052TE). All variants have the same canned motor with a motor power of 7.5 kW at 50 Hz to 8.5 kW at 60 Hz for mains voltages from 200 V to 460 V. They differ mainly in the oil filling: mineral oil LEYBONOL LVO 130, ester oil LEYBONOL LVO 210, PFPE LEYBONOL LVO 400. The H versions have an ACE damper in the pressure equalisation line. The 100 Hz versions are approved for frequency converter operation up to 6000 min⁻¹. Three variants are supplied for horizontal pumping direction. One variant has a water-cooled motor.

Features of the RUVAC WS/WSU

  • Air-cooled canned motor: no shaft feedthrough to atmosphere, integral leak rate ≤ 1 × 10⁻⁴ mbar·l/s
  • Temperature monitoring in the motor's stator winding; separate fan under the fan cover
  • Operation on 50 and 60 Hz mains; higher speeds are possible with a frequency converter
  • All elastomer seals made of FPM (FKM)
  • WSU: integrated pressure equalisation line with differential pressure valve as overload protection
  • Supplied for vertical pumping direction; conversion to horizontal pumping direction possible by the customer
  • Oil filling supplied separately; inlet flange with dirt trap, pump vented with nitrogen for corrosion protection