RUVAC WA 251Pumping speed 210 m³/hUltimate pressure 8 × 10-4 mbarRUVAC WA 501 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor
The Leybold RUVAC WA 501 is an air-cooled Roots vacuum pump without a pressure equalisation line: 505 m³/h nominal pumping speed at 50 Hz, 410 m³/h maximum effective pumping speed and a 2.2 kW IE3 motor. Ehrler & Beck supplies the RUVAC WA 501 in four variants with matching accessories, spare parts and service.
Request a quote for this product Read more
- Pumping speed 410 m³/h 50 Hz 530 m³/h 60 Hz
- Ultimate pressure 0.04 mbar
- Rated motor power 2.2 kW 50 Hz 2.2 kW 60 Hz
| Variant | Part number |
|---|---|
| 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor (selected) | 11730 |
| 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor, horizontal pumping direction | 12838TE |
| without motor, prepared for IEC standard motor | 11734 |
| without motor, prepared for IEC standard motor | 11734TE |
Leybold RUVAC WA 501 – Roots pump with 505 m³/h nominal pumping speed
The RUVAC WA 501 doubles the nominal pumping speed of size 251 with the same DN 63 ISO-K connection flanges. As a WA version without pressure equalisation line, it is switched on at about 100 mbar; the permissible pressure difference in continuous operation is 80 mbar. Leybold gives the data with a SOGEVAC SV 200 as the backing pump. The nominal pumping speed is 505 m³/h at 50 Hz and 606 m³/h at 60 Hz, the maximum effective pumping speed 410 and 530 m³/h respectively. The pump measures 840 × 310 × 340 mm, weighs 137 kg and is connected via DN 63 ISO-K; the noise level is below 67 dB(A).Typical applications
Roots pumps of the RUVAC series work as boosters in front of an oil-sealed or dry backing pump. Leybold lists heat treatment and furnace construction, metallurgy, large-area coating including architectural glass, load-lock chambers, high-speed food packaging, the evacuation of lamps, and crystal pulling systems for the semiconductor and solar industries as typical applications.Variants of the RUVAC WA 501
The RUVAC WA 501 is available from Ehrler & Beck in four variants (part numbers 11730, 12838TE, 11734, 11734TE). The motor power of all versions with motor is 2.2 kW at 50 and 60 Hz; the mains voltage ranges from 200–240 V to 380–460 V. The pump is also available without a motor for customer IEC motors.Features of the RUVAC WA/WAU
- Air-cooled, flange-mounted three-phase standard motor of efficiency class IE3, easily exchangeable for customer motors
- Shaft seals and elastomer seals made of FPM (FKM); seals and their housing easy to replace
- WAU: integrated pressure equalisation line as overload protection at high pressures
- Supplied for vertical pumping direction; conversion to horizontal pumping direction possible by the customer
- LEYBONOL LVO 130 lubricant, filling supplied separately; inlet flange with seal and dirt trap
- ATEX category 3i (inside) as standard, valid only for 50 Hz operation
| Pumping speed 50Hz | 410 |
|---|---|
| Pumping speed 60Hz | 530 |
| Ultimate pressure | 0.04 |
| Rated motor power 50Hz | 2.2 |
| Rated motor power 60Hz | 2.2 |
| Motor efficiency class | IE3 |
| Weight | 137 |
| Length | 84 |
| Width | 31 |
| Height | 34 |
| Inlet connection flange | DN 63 ISO-K |
| Outlet connection flange | DN 63 ISO-K |
| Noise level | 67 dB(A) |
| Cooling method | Air cooling |
| Oil type | LEYBONOL LVO 130 |
Additional technical data
| Technical data | Value |
|---|---|
| Nominal pumping speed | 505 m³/h (50 Hz) / 606 m³/h (60 Hz) |
| Max. effective pumping speed | 410 m³/h (50 Hz) / 530 m³/h (60 Hz) with backing pump SOGEVAC SV 200 |
| Ultimate partial pressure | < 8 × 10⁻³ mbar |
| Ultimate total pressure | < 4 × 10⁻² mbar (with backing pump SOGEVAC SV 200) |
| Cut-in pressure | approx. 100 mbar |
| Max. permissible pressure difference in continuous operation | 80 mbar |
| Leak rate, integral | ≤ 5 × 10⁻⁴ mbar·l/s |
| Version | 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor |
| Motor power | 2.2 kW (50/60 Hz), IE3 |
| Mains voltage | 200-240 V / 380-460 V, 50/60 Hz, 3-phase |
| Rated current 50 Hz | 380-415 V (Y): 4.6 A; 220-240 V (Δ): 7.9 A; 200 V (YY): 8.9 A |
| Rated current 60 Hz | 440-460 V (Y): 4.0 A; 380 V (Y): 4.4 A; 220 V (Δ): 7.6 A; 200 V (YY): 8.4 A |
| Motor speed 50 / 60 Hz | 2870 / 3450 min⁻¹ |
| Nominal pump speed 50 / 60 Hz | 3000 / 3600 min⁻¹ |
| Max. permissible speed | 3600 min⁻¹ |
| Motor protection class | IP 55 |
| Thermal class | F |
| Oil filling bearing chamber, vertical pumping direction | 0.9 l (initial filling) / 0.8 l |
| Oil filling bearing chamber, horizontal pumping direction | 0.8 l (initial filling) / 0.7 l |
| Oil filling shaft seal housing | 1.0 l |
| Lubricant | LEYBONOL LVO 130 |
| Connection flanges | DN 63 ISO-K (pump flange PN 6 to DIN 2501 with collar flange) |
| Noise level | < 67 dB(A) at operating pressure < 0.1 mbar |
| Permissible ambient temperature | 12 to 40 °C |
| Materials (in contact with gas) | Carbon steel, crNi steel, grey cast iron, FPM (FKM) |
| ATEX | Category 3i (inside), only for 50 Hz operation |
| Product name | Part number |
|---|---|
| Shaft seal replacement kit RUVAC WA/WAU 251/501 | EK110002661 |
| Major service kit RUVAC WA 501 | EK110002664 |
| Seal kit RUVAC WA/WAU(H) 501 | 19464 |
| Product name | Part number |
|---|---|
| Loose flange with retaining ring DN 63 ISO-K (required for ISO-K connection) | 26747T |
| Temperature sensor Pt 100 | 155010 |
| Oil drain facility M 16 x 1.5 with straight drain coupling | 19002 |
| Oil drain facility M 16 x 1.5 with 90° drain coupling | 20014271 |
| Pressure switch PS 115 (stainless steel), adjustable | 16004 |
| Pressure switch adjustment | 16005 |
| Adapter M 16 x 1.5 – DN 16 KF (for PS 115) | 16840 |
| Elbow 90° DN 16 ISO-KF | 18436 |
| Centring ring Al with CR (neoprene) O-ring, DN 16 ISO-KF | 18326 |
| Clamping ring Al (ADC 12), DN 10/16 ISO-KF | 18341 |
| Switching amplifier SV 110, 230 V | 16078 |
| Roots adapter for TRIVAC D 40/65 B | 16830 |
| LEYBONOL LVO 130, 1 litre | L13001 |
| LEYBONOL LVO 130, 5 litres | L13005 |
| LEYBONOL LVO 130, 20 litres | L13020 |
| LEYBONOL LVO 130, 208 litres | L13099 |