VTLF 2.200Pumping speed 178 m³/hUltimate pressure 200 mbarVTLF 2.360 3Ph 400 V 50 Hz / 460, 400 V 60 Hz
The Becker VTLF 2.360 is a dry-running rotary vane vacuum pump with a pumping speed of 351 m³/h at 50 Hz (402 m³/h at 60 Hz) and a vacuum down to 250 mbar absolute. It works oil-free and is designed for high pumping speeds in the rough vacuum range. Ehrler & Beck advises on selection, accessories and service.
Request a quote for this product Read more
- Pumping speed 351 m³/h 50 Hz 402 m³/h 60 Hz
- Ultimate pressure 250 mbar
- Rated motor power 11 kW 50 Hz 13.2 kW 60 Hz
| Motor variant | Motor order number |
|---|---|
| 3Ph 400 V 50 Hz / 460, 400 V 60 Hz (selected) | 43289490300003TA |
| 3Ph 230/460, 208 V 60 Hz, UL/CSA | 43389407300114TA |
| 3Ph 200/350 V 50 Hz / 220/380–400, 200/350 V 60 Hz | 43289453300003TA |
| 3Ph 400/690 V 60 Hz, UL/CSA | 43389454300114TA |
Becker VTLF 2.360 – oil-free rotary vane vacuum pump for high pumping speeds
The VTLF 2.360 delivers 351 m³/h at 50 Hz and 402 m³/h at 60 Hz and reaches a vacuum of 250 mbar absolute (50 Hz) or 350 mbar (60 Hz). The installed motor power is 11.0 kW at 50 Hz and 13.2 kW at 60 Hz, the sound pressure level 80.5 dB(A) and 82.5 dB(A) respectively. Without motor the pump weighs 151 kg; the overall length with motor is 1174 mm depending on the motor, width 644 mm, height 528 mm. Suction connection G 2 1/2", exhaust connection G 2".Dry-running rotary vane principle
The pump works without oil in the pumping chamber; there are no oil changes. The vacuum safety valve and the blow-off valve are each fitted with a silencer, and the inlet filter is integrated. Effective noise-reduction measures ensure quiet operation.Maintenance
The transparent filter cover shows contamination at once, and the enlarged filter area allows longer change intervals. Maintenance can be carried out on site, so downtimes stay short. The robust design is intended for long running times even under demanding conditions.Versions and accessories
- Integrated non-return valve: version on request
- External inlet filter: accessory, on request
- Acoustic hood SH 10: accessory, on request
- Further combinations: on request
Advice and service
Ehrler & Beck supports you in selecting the right size and motor version, supplies accessories and spare parts and carries out maintenance and repair.| Pumping speed 50Hz | 351 |
|---|---|
| Pumping speed 60Hz | 402 |
| Ultimate pressure | 250 |
| Rated motor power 50Hz | 11 |
| Rated motor power 60Hz | 13.2 |
| Motor efficiency class | IE3 |
| Weight | 263 |
| Length | 117.4 |
| Width | 64.4 |
| Height | 52.8 |
| Inlet connection flange | G 2 1/2" |
| Outlet connection flange | G 2" |
| Noise level | 80.5 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Further technical data
| Motor | Data |
|---|---|
| Motor order number | 43289490300003TA |
| Pump types according to Becker | VTLF 2.360 |
| Phases | 3~ (three-phase) |
| 50 Hz | 11.0 kW (14.8 hp) · Δ400 V · IE3 · 1479 min⁻¹ · 23.9 A |
| 60 Hz | 13.2 kW (17.7 hp) · Δ460 V · IE3 · 1777 min⁻¹ · 23.7 A 13.2 kW (17.7 hp) · Δ400 V · 1768 min⁻¹ · 24.9 A |
| Version | CE IP55 • ISO F • PTO |
| Motor length M1 | 460.0 mm |
| Overall length L1 with pump | 1174.0 mm |
| Motor weight | 105.5 kg |
| Motor data according to | Becker Motor Specifications for Pumps and Blowers (09/2026), item 4-28 |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Rotary vane vacuum pump, dry-running (oil-free), air-cooled |
| Pumping speed 50 Hz / 60 Hz | 351 / 402 m³/h |
| Vacuum (absolute) 50 Hz / 60 Hz | 250 / 350 mbar |
| Installed motor power 50 Hz / 60 Hz | 11.0 / 13.2 kW |
| Sound pressure level 50 Hz / 60 Hz | 80.5 / 82.5 dB(A) (DIN EN ISO 3744, 1 m) |
| Weight without motor | 151 kg |
| Weight with motor | approx. 263 kg (Becker catalogue 2026, depending on the motor) |
| Length with motor | 1174 mm (depending on the motor) |
| Width × height | 644 × 528 mm |
| Suction connection / exhaust connection | G 2 1/2" / G 2" |
| Reference data | 1000 mbar, 20 °C, tolerance ±5 % |
| Version / accessory | Description |
|---|---|
| Integrated non-return valve | Version on request |
| External inlet filter | Accessory, on request |
| Sound enclosure SH 10 | Accessory, on request |
| Further combinations | on request |