KVX 3.60Pumping speed 55 m³/hUltimate pressure 100 mbarKVX 3.100 3Ph 400/690 V 60 Hz, UL/CSA
The Becker KVX 3.100 is a dry-running rotary vane vacuum pump of the X series with a pumping speed of 98 m³/h at 50 Hz (112 m³/h at 60 Hz) and a vacuum down to 100 mbar absolute. Specially developed vanes achieve service lives of up to 20,000 operating hours. Ehrler & Beck advises on selection, accessories and service.
Request a quote for this product Read more
- Pumping speed 98 m³/h 50 Hz 112 m³/h 60 Hz
- Ultimate pressure 100 mbar
- Rated motor power 3.6 kW 60 Hz
| Motor variant | Motor order number |
|---|---|
| 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz | 42489422300003RE |
| 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz, UL/CSA | 42489422300114RE |
| 3Ph 400 V 50 Hz / 230/460, 208 V 60 Hz, UL/CSA | 42589407300114RE |
| 3Ph 200/400 V 50 Hz / 230/460, 208 V 60 Hz, UL/CSA | 42589407300114TA |
| 3Ph 200/350 V 50 Hz / 220/380–400, 200/350 V 60 Hz, UL/CSA | 42489453300114RE |
| 3Ph 400/690 V 60 Hz, UL/CSA (selected) | 42589454300114RE |
| 3Ph 290/500 V 50 Hz / 330/575 V 60 Hz, UL/CSA | 42489457300114RE |
| 3Ph 230/460, 208 V 60 Hz, UL/CSA, only via Becker Pumps USA | 4M224G184TC |
Becker KVX 3.100 – oil-free rotary vane vacuum pump of the X series
The KVX 3.100 delivers 98 m³/h at 50 Hz and 112 m³/h at 60 Hz and reaches a vacuum of 100 mbar absolute. The installed motor power is 3.0 kW at 50 Hz and 3.6 kW at 60 Hz, the sound pressure level 75 dB(A) and 77 dB(A) respectively. The pump weighs 71 kg without motor; the overall length with motor is 838–862 mm depending on the motor, width 470 mm, height 336 mm. Suction and optional exhaust connection G 1 1/2".Dry-running rotary vane principle
Without oil in the pumping chamber there are no oil changes and no oil mist in the exhaust air. Becker designs the KVX pumps for continuous operation; the motor drives the rotor directly via a common shaft, which keeps the design compact. The inlet filter, blow-off valve and vacuum regulating valve are integrated, and noise-reduction measures ensure quiet operation.X series
For the X series Becker has developed a special vane material: the vanes achieve service lives of up to 20,000 operating hours or 3 years, and there is virtually no abrasion. Becker therefore describes the pumps as suitable for precision processes under clean-room conditions; the air flow is low in pulsation. Size, motor and connections correspond to the KVT 3.100.Design and maintenance
The robust construction is intended for long running times even under demanding conditions. Maintenance can be carried out on site, which keeps downtimes short. Numerous motor versions are available for the KVX 3.100.Versions and accessories
- KVX 3.100/0-54: version with exhaust connection (G 1 1/2")
- External inlet filter: accessory, on request
- Acoustic hood SH 13: accessory, on request
- Further combinations: on request
Advice and service
Ehrler & Beck supports you in selecting the right size and motor version, supplies accessories and spare parts and carries out maintenance and repair.| Pumping speed 50Hz | 98 |
|---|---|
| Pumping speed 60Hz | 112 |
| Ultimate pressure | 100 |
| Rated motor power 60Hz | 3.6 |
| Motor efficiency class | IE3 |
| Weight | 108 |
| Length | 85.1 |
| Width | 47 |
| Height | 33.6 |
| Inlet connection flange | G 1 1/2" |
| Noise level | 75 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Further technical data
| Motor | Data |
|---|---|
| Motor order number | 42589454300114RE |
| Pump types according to Becker | KDT 3.60 KDT 3.80 KVT/KVX 3.100 |
| Phases | 3~ (three-phase) |
| 60 Hz | 3.6 kW (4.8 hp) · Δ400/Y690 V · IE3 · 1760 min⁻¹ · 7.6/4.4 A |
| Version | CE • UL • CSA • CC IP55 • ISO F • PTO |
| Motor length M1 | 350.0 mm |
| Overall length L1 with pump | 851.0 mm |
| Motor weight | 37.0 kg |
| Motor data according to | Becker Motor Specifications for Pumps and Blowers (09/2026), item 3-12 |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Rotary vane vacuum pump, dry-running (oil-free), air-cooled, X series |
| Pumping speed 50 Hz / 60 Hz | 98 / 112 m³/h |
| Vacuum (absolute) 50 Hz / 60 Hz | 100 / 100 mbar |
| Installed motor power 50 Hz / 60 Hz | 3.0 / 3.6 kW |
| Sound pressure level 50 Hz / 60 Hz | 75 / 77 dB(A) (DIN EN ISO 3744, 1 m) |
| Weight without motor | 71 kg |
| Weight with motor | up to 108 kg (Becker catalogue 2026, depending on the motor) |
| Length with motor | 838–862 mm (depending on the motor) |
| Width × height | 470 × 336 mm |
| Suction connection | G 1 1/2" |
| Exhaust connection (version /0-54) | G 1 1/2" |
| Reference data | 1000 mbar, 20 °C, tolerance ±5 % |
| Vane service life (X series) | up to 20,000 operating hours or 3 years |
| Version / accessory | Description |
|---|---|
| KVX 3.100/0-54 | Version with exhaust connection (G 1 1/2") |
| External inlet filter | Accessory, on request |
| Sound enclosure SH 13 | Accessory, on request |
| Further combinations | on request |