KVT 3.60Pumping speed 55 m³/hUltimate pressure 100 mbarKVT 3.140 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz
The Becker KVT 3.140 is a dry-running rotary vane vacuum pump with a pumping speed of 129 m³/h at 50 Hz (154 m³/h at 60 Hz) and a vacuum down to 100 mbar absolute. It works oil-free, is air-cooled and designed for continuous operation. Ehrler & Beck advises on selection, accessories and service.
Request a quote for this product Read more
- Pumping speed 129 m³/h 50 Hz 154 m³/h 60 Hz
- Ultimate pressure 100 mbar
- Rated motor power 4 kW 50 Hz 4.8 kW 60 Hz
| Motor variant | Motor order number |
|---|---|
| 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz (selected) | 42689422300003RE |
| 3Ph 200/400 V 50 Hz / 230/460, 208 V 60 Hz, UL/CSA | 42789407300114TA |
| 3Ph 230/460, 208 V 60 Hz, UL/CSA | 42789407302114TA |
| 3Ph 200/350 V 50 Hz / 220/380–400, 200/350 V 60 Hz, UL/CSA | 42689453300114TA |
| 3Ph 400 V 60 Hz, UL/CSA, 4.5 kW | 42789454300114TA |
| 3Ph 400 V 60 Hz, UL/CSA, 4.8 kW | 42789454300114RE |
| 3Ph 230/460, 208 V 60 Hz, UL/CSA, only via Becker Pumps USA | 4M224G213TC |
Becker KVT 3.140 – oil-free rotary vane vacuum pump for continuous operation
The KVT 3.140 delivers 129 m³/h at 50 Hz and 154 m³/h at 60 Hz and reaches a vacuum of 100 mbar absolute (50 Hz) or 200 mbar (60 Hz). The installed motor power is 4.0 kW at 50 Hz and 4.5–4.8 kW at 60 Hz, the sound pressure level 76 dB(A) and 79 dB(A) respectively. The pump weighs 78 kg without motor; the overall length with motor is 829–966.5 mm depending on the motor, width 470 mm, height 336 mm. Suction and optional exhaust connection G 1 1/2".Dry-running rotary vane principle
Without oil in the pumping chamber there are no oil changes and no oil mist in the exhaust air. Becker designs the KVT pumps for continuous operation; the motor drives the rotor directly via a common shaft, which keeps the design compact. The inlet filter, blow-off valve and vacuum regulating valve are integrated, and noise-reduction measures ensure quiet operation.Design and maintenance
The robust construction is intended for long running times even under demanding conditions. Maintenance can be carried out on site, which keeps downtimes short. Numerous motor versions are available for the KVT 3.140.Versions and accessories
- KVT 3.140/0-54: version with exhaust connection (G 1 1/2")
- Increased corrosion protection: version on request
- VARIAIR KVT 3.140/0-400: version with integrated VARIAIR frequency converter
- External inlet filter: accessory, on request
- Acoustic hood SH 13: accessory, on request
- Further combinations: on request
Advice and service
Ehrler & Beck supports you in selecting the right size and motor version, supplies accessories and spare parts and carries out maintenance and repair.| Pumping speed 50Hz | 129 |
|---|---|
| Pumping speed 60Hz | 154 |
| Ultimate pressure | 100 |
| Rated motor power 50Hz | 4 |
| Rated motor power 60Hz | 4.8 |
| Motor efficiency class | IE3 |
| Weight | 142.5 |
| Length | 82.9 |
| Width | 47 |
| Height | 33.6 |
| Inlet connection flange | G 1 1/2" |
| Noise level | 76 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Further technical data
| Motor | Data |
|---|---|
| Motor order number | 42689422300003RE |
| Pump types according to Becker | KDT 3.80 KDT 3.100 KVT/KVX 3.140 |
| Phases | 3~ (three-phase) |
| 50 Hz | 4.0 kW (5.4 hp) · Δ230/Y400 V · IE3 · 1447 min⁻¹ · 15.5/8.9 A |
| 60 Hz | 4.8 kW (6.4 hp) · Δ265/Y460 V · 1744 min⁻¹ · 14.9/8.6 A 4.8 kW (6.4 hp) · Δ230/Y400 V · 1722 min⁻¹ · 15.9/9.2 A |
| Version | CE IP55 • ISO F • PTO |
| Motor length M1 | 328.0 mm |
| Overall length L1 with pump | 829.0 mm |
| Motor weight | 34.0 kg |
| Motor data according to | Becker Motor Specifications for Pumps and Blowers (09/2026), item 3-15 |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Rotary vane vacuum pump, dry-running (oil-free), air-cooled |
| Pumping speed 50 Hz / 60 Hz | 129 / 154 m³/h |
| Vacuum (absolute) 50 Hz / 60 Hz | 100 / 200 mbar |
| Installed motor power 50 Hz / 60 Hz | 4.0 / 4.5–4.8 kW |
| Sound pressure level 50 Hz / 60 Hz | 76 / 79 dB(A) (DIN EN ISO 3744, 1 m) |
| Weight without motor | 78 kg |
| Weight with motor | up to 142.5 kg (Becker catalogue 2026, depending on the motor) |
| Length with motor | 829–966.5 mm (depending on the motor) |
| Width × height | 470 × 336 mm |
| Suction connection | G 1 1/2" |
| Exhaust connection (version /0-54) | G 1 1/2" |
| Reference data | 1000 mbar, 20 °C, tolerance ±5 % |
| Version / accessory | Description |
|---|---|
| KVT 3.140/0-54 | Version with exhaust connection (G 1 1/2") |
| Enhanced corrosion protection | Version on request |
| VARIAIR KVT 3.140/0-400 | Version with integrated VARIAIR frequency converter |
| External inlet filter | Accessory, on request |
| Sound enclosure SH 13 | Accessory, on request |