KVT 3.140 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz

The Becker KVT 3.140 is a dry-running rotary vane vacuum pump with a pumping speed of 129 m³/h at 50 Hz (154 m³/h at 60 Hz) and a vacuum down to 100 mbar absolute. It works oil-free, is air-cooled and designed for continuous operation. Ehrler & Beck advises on selection, accessories and service.

Request a quote for this product Read more

  • Pumping speed 129 m³/h 50 Hz 154 m³/h 60 Hz
  • Ultimate pressure 100 mbar
  • Rated motor power 4 kW 50 Hz 4.8 kW 60 Hz
Available variants
Motor variant Motor order number
3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz (selected) 42689422300003RE
3Ph 200/400 V 50 Hz / 230/460, 208 V 60 Hz, UL/CSA 42789407300114TA
3Ph 230/460, 208 V 60 Hz, UL/CSA 42789407302114TA
3Ph 200/350 V 50 Hz / 220/380–400, 200/350 V 60 Hz, UL/CSA 42689453300114TA
3Ph 400 V 60 Hz, UL/CSA, 4.5 kW 42789454300114TA
3Ph 400 V 60 Hz, UL/CSA, 4.8 kW 42789454300114RE
3Ph 230/460, 208 V 60 Hz, UL/CSA, only via Becker Pumps USA 4M224G213TC

Becker KVT 3.140 – oil-free rotary vane vacuum pump for continuous operation

The KVT 3.140 delivers 129 m³/h at 50 Hz and 154 m³/h at 60 Hz and reaches a vacuum of 100 mbar absolute (50 Hz) or 200 mbar (60 Hz). The installed motor power is 4.0 kW at 50 Hz and 4.5–4.8 kW at 60 Hz, the sound pressure level 76 dB(A) and 79 dB(A) respectively. The pump weighs 78 kg without motor; the overall length with motor is 829–966.5 mm depending on the motor, width 470 mm, height 336 mm. Suction and optional exhaust connection G 1 1/2".

Dry-running rotary vane principle

Without oil in the pumping chamber there are no oil changes and no oil mist in the exhaust air. Becker designs the KVT pumps for continuous operation; the motor drives the rotor directly via a common shaft, which keeps the design compact. The inlet filter, blow-off valve and vacuum regulating valve are integrated, and noise-reduction measures ensure quiet operation.

Design and maintenance

The robust construction is intended for long running times even under demanding conditions. Maintenance can be carried out on site, which keeps downtimes short. Numerous motor versions are available for the KVT 3.140.

Versions and accessories

  • KVT 3.140/0-54: version with exhaust connection (G 1 1/2")
  • Increased corrosion protection: version on request
  • VARIAIR KVT 3.140/0-400: version with integrated VARIAIR frequency converter
  • External inlet filter: accessory, on request
  • Acoustic hood SH 13: accessory, on request
  • Further combinations: on request

Advice and service

Ehrler & Beck supports you in selecting the right size and motor version, supplies accessories and spare parts and carries out maintenance and repair.