VASF 2.50/2Pumping speed 24 m³/h
VASF 2.80/1
The Becker VASF 2.80/1 (VARIAIR Speed Flow) is a compact, single-stage side channel blower with VARIAIR frequency converter: up to 90 m³/h, depending on the version vacuum down to −290 mbar and pressure up to +290 mbar. Ehrler & Beck advises on the right version.
Request a quote for this product Read more
- Pumping speed 90 m³/h 50 Hz 90 m³/h 60 Hz
Becker VASF 2.80/1 – VARIAIR Speed Flow side channel blower
The VASF 2.80/1 is a single-stage, air-cooled side channel blower with VARIAIR frequency converter. It delivers up to 90 m³/h (frequency 50–250 Hz) and, depending on the version, reaches down to −290 mbar relative in suction operation or up to +290 mbar relative in pressure operation. Dimensions 391 × 176 × 291 mm (AC); 391 × 173 × 268 mm (DC 48 V), suction and pressure connection G 1 1/4".Versions
Becker offers the VASF 2.80/1 for various supply voltages, as a Basic version for an external VARIAIR frequency converter and as a gas-tight compressor version:- AC 200–230 V (-0.AC230): vacuum down to −280 mbar, pressure up to +280 mbar, 1.1 kW, max. 10 A, 61 dB(A), 15 kg
- DC 48 V (-0.DC048): vacuum down to −290 mbar, pressure up to +290 mbar, 1.1 kW, max. 25 A, 65 dB(A), 14.7 kg
- Basic AC 230 V / AC 115 V / DC 48 V: vacuum down to −190 / −190 / −170 mbar, pressure up to +190 / +190 / +170 mbar, 0.65 / 0.64 / 0.70 kW, 63–85 dB(A), 8.6–10.1 kg
- Gas-tight (-1.AC230): 91 m³/h, max. pressure ratio 1.28 p/p, 1.1 kW, 59 dB(A), 14 kg, connections DN 40 ISO-KF; leak rate < 1 × 10⁻⁵ mbar·l/s (helium leak test, whole unit), pressure ratio measured for air
- Gas-tight Basic (-1.AC230 / -1.AC115): 90 m³/h, max. pressure ratio 1.19 p/p, 0.65 / 0.64 kW, 59 dB(A), 9.3 kg, connections DN 40 ISO-KF
Speed control and contact-free compression
The volume flow can be set precisely via the speed. The impeller rotates without contact and the sealed bearings need no lubrication – the blower works oil-free.Advice and service
Ehrler & Beck supports you in selecting the right version, supplies accessories and spare parts and carries out maintenance and repair.| Pumping speed 50Hz | 90 |
|---|---|
| Pumping speed 60Hz | 90 |
| Weight | 15 |
| Length | 39.1 |
| Width | 17.6 |
| Height | 29.1 |
| Inlet connection flange | G 1 1/4" |
| Outlet connection flange | G 1 1/4" |
| Noise level | 61 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Side channel blower, single-stage, air-cooled, with VARIAIR frequency converter (VARIAIR Speed Flow), contact-free compression – as vacuum pump or compressor |
| Max. volume flow | 90 m³/h |
| Frequency | 50–250 Hz |
| AC 200–230 V (-0.AC230) | Vacuum down to −280 mbar, pressure up to +280 mbar, 1.1 kW, max. 10 A, 61 dB(A), 15 kg |
| DC 48 V (-0.DC048) | Vacuum down to −290 mbar, pressure up to +290 mbar, 1.1 kW, max. 25 A, 65 dB(A), 14.7 kg |
| Basic AC 230 V / AC 115 V / DC 48 V | Vacuum down to −190 / −190 / −170 mbar, pressure up to +190 / +190 / +170 mbar, 0.65 / 0.64 / 0.70 kW, 63–85 dB(A), 8.6–10.1 kg |
| Gas-tight (-1.AC230) | 91 m³/h, max. pressure ratio 1.28 p/p, 1.1 kW, 59 dB(A), 14 kg, connections DN 40 ISO-KF; leak rate < 1 × 10⁻⁵ mbar·l/s (helium leak test, whole unit), pressure ratio measured for air |
| Gas-tight Basic (-1.AC230 / -1.AC115) | 90 m³/h, max. pressure ratio 1.19 p/p, 0.65 / 0.64 kW, 59 dB(A), 9.3 kg, connections DN 40 ISO-KF |
| Dimensions L × W × H | 391 × 176 × 291 mm (AC); 391 × 173 × 268 mm (DC 48 V) |
| Suction and pressure connection | G 1 1/4" (for gas-tight versions see above) |
| Notes | kW figures = converter power; weights with motor and converter (Basic: with motor, without external converter); reference data 1000 mbar, 20 °C, tolerance ±10 % |