RUVAC WH 7000 3Ph 200 V 50 Hz / 230 V 60 Hz; 11 kW motor, mains operation or operation with external frequency converter, PFPE LEYBONOL LVO 400

The Leybold RUVAC WH 7000 is a water-cooled Roots vacuum pump with a hermetically encapsulated motor without a shaft seal to atmosphere: 7000 m³/h nominal pumping speed at 50 Hz and 4700 m³/h maximum effective pumping speed. Ehrler & Beck supplies the RUVAC WH 7000 in 19 variants with matching accessories, spare parts and service.

Request a quote for this product Read more

  • Pumping speed 4,700 m³/h 50 Hz 5,300 m³/h 60 Hz
  • Rated motor power 11 kW 50 Hz 11 kW 60 Hz
Available variants
Variant Part number
3Ph 400 V 50 Hz / 460 V 60 Hz; 11 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 1227700V14
3Ph 200 V 50 Hz / 230 V 60 Hz; 11 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 1227700V19
3Ph 400 V 50 Hz / 460 V 60 Hz; 11 kW motor, mains operation or operation with external frequency converter, PFPE LEYBONOL LVO 400 1227700V24
3Ph 400 V 50 Hz / 460 V 60 Hz; 18.5 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 1227700V13
3Ph 400 V 50 Hz / 460 V 60 Hz; 18.5 kW motor, mains operation or operation with external frequency converter, heavy-duty version with gas-sealed impellers and purge gas, ester oil LEYBONOL LVO 210 1227700V10
3Ph 400 V 50 Hz / 460 V 60 Hz; 11 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 127700V14
3Ph 200 V 50/60 Hz; 11 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 127700V19
3Ph 400 V 50 Hz / 460 V 60 Hz; 11 kW motor, mains operation or operation with external frequency converter, PFPE LEYBONOL LVO 400 127700V24
3Ph 200 V 50 Hz / 230 V 60 Hz; 11 kW motor, mains operation or operation with external frequency converter, PFPE LEYBONOL LVO 400 (selected) 127700V29
3Ph 400 V 50 Hz / 460 V 60 Hz; 18.5 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 127700V13
3Ph 400 V 50 Hz / 460 V 60 Hz; 18.5 kW motor, mains operation or operation with external frequency converter, heavy-duty version with gas-sealed impellers and purge gas, ester oil LEYBONOL LVO 210 127700V10
3Ph 400 V 50 Hz / 460 V 60 Hz; 18.5 kW motor, mains operation or operation with external frequency converter, heavy-duty version with gas-sealed impellers and purge gas, PFPE LEYBONOL LVO 400 127700V20
3Ph 400 V; 11 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 155160
3Ph 200 V; 11 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 155161V
3Ph 400 V; 11 kW motor, mains operation or operation with external frequency converter, PFPE LEYBONOL LVO 400 155165
3Ph 200 V; 11 kW motor, mains operation or operation with external frequency converter, PFPE LEYBONOL LVO 400 155164V
3Ph 400 V; 18.5 kW motor, mains operation or operation with external frequency converter, ester oil LEYBONOL LVO 210 155167
3Ph 400 V; 18.5 kW motor, mains operation or operation with external frequency converter, heavy-duty version with gas-sealed impellers and purge gas, ester oil LEYBONOL LVO 210 155163V
3Ph 400 V; 11 kW motor with internal frequency converter, IP 55, ester oil LEYBONOL LVO 210 167194V

Leybold RUVAC WH 7000 – water-cooled Roots pump with 7000 m³/h nominal pumping speed

With 7000 m³/h nominal pumping speed, the RUVAC WH 7000 is the largest pump in the WH series; with a frequency converter it reaches up to 9800 m³/h at 70 Hz. The DN 320 ISO-K inlet flange is designed for large chambers, the reduced DN 160 ISO-K outlet flange for direct mounting on the backing pump. 11 kW and 18.5 kW motors, heavy-duty versions with purge gas and oil fillings with ester oil or PFPE are available. The nominal pumping speed is 7000 m³/h at 50 Hz and 8400 m³/h at 60 Hz, the maximum effective pumping speed 4700 and 5300 m³/h respectively. In the standard version the pump measures 1433 × 540 × 414 mm, weighs 650 kg and is connected via DN 320 ISO-K (inlet) and DN 160 ISO-K (outlet); the noise level is below 63 dB(A).

Typical applications

Leybold developed the WH series for applications with high demands on operating pressure, cycle time and system availability: display production, solar industry, furnace construction, industrial coating, research and space simulation. The pumps work as boosters in front of dry backing pumps of the DRYVAC, SCREWLINE and LEYVAC series or in front of oil-sealed SOGEVAC pumps.

Variants of the RUVAC WH 7000

The RUVAC WH 7000 is available from Ehrler & Beck in 19 variants (part numbers 1227700V14, 1227700V19, 1227700V24, 1227700V13, 1227700V10, 127700V14, 127700V19, 127700V24, 127700V29, 127700V13, 127700V10, 127700V20, 155160, 155161V, 155165, 155164V, 155167, 155163V, 167194V). The motor power ranges from 11 kW to 18.5 kW. Available oil fillings: ester oil LEYBONOL LVO 210, PFPE LEYBONOL LVO 400. Several part numbers describe the same version: Leybold has changed the numbers of the series twice, so the numbers from the catalogue, the current operating instructions and the web shop are listed together.

Features of the RUVAC WH/WHU

  • Hermetically encapsulated, water-cooled motor: no shaft seal to atmosphere, no oil leaks, suitable for toxic and corrosive media
  • Integral leak rate below 1 × 10⁻⁵ mbar·l/s
  • Parts carrying cooling water made of stainless steel; low oil temperature and long bearing life, low noise and heat emission
  • Reduced outlet flange for direct mounting on the backing pump without an intermediate frame
  • WHU: patented bypass line with control flap for fast pump-down from atmospheric pressure
  • According to Leybold, four years of operation without maintenance when the recommended lubricant is used
  • Supplied with standard vibration absorbers and a seal with dirt trap in the inlet flange