RUVAC WA 251Pumping speed 210 m³/hUltimate pressure 8 × 10-4 mbarRUVAC WAU 2001 without motor, prepared for IEC standard motor
The Leybold RUVAC WAU 2001 is an air-cooled Roots vacuum pump with integrated pressure equalisation line: 2050 m³/h nominal pumping speed at 50 Hz, 1850 m³/h maximum effective pumping speed and a 7.5 kW IE3 motor. Ehrler & Beck supplies the RUVAC WAU 2001 in seven variants with matching accessories, spare parts and service.
Request a quote for this product Read more
- Pumping speed 1,850 m³/h 50 Hz 2,100 m³/h 60 Hz
- Ultimate pressure 0.04 mbar
| Variant | Part number |
|---|---|
| 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor | 11751 |
| 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor, T version | 11751T |
| 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor, TE version (CE) | 11751TE |
| without motor, prepared for IEC standard motor (selected) | 11322 |
| without motor, prepared for IEC standard motor | 11322TE |
| 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor, H version with ACE vibration absorber | 11851 |
| 3Ph 200-240/380-460 V 50/60 Hz, IE3 motor, H version with ACE vibration absorber | 11851TE |
Leybold RUVAC WAU 2001 – Roots pump with 2050 m³/h nominal pumping speed
The RUVAC WAU 2001 is the top model of the air-cooled RUVAC pumps with pressure equalisation line: 2050 m³/h nominal pumping speed, start at atmospheric pressure and a 7.5 kW IE3 motor. It is also available as an H version with ACE vibration absorber and with the LEYTRONIC frequency converter. The nominal pumping speed is 2050 m³/h at 50 Hz and 2460 m³/h at 60 Hz, the maximum effective pumping speed 1850 and 2100 m³/h respectively. The pump measures 1277 × 638 × 530 mm, weighs 452 kg and is connected via DN 160 ISO-K; the noise level is below 80 dB(A).Typical applications
Roots pumps of the RUVAC series work as boosters in front of an oil-sealed or dry backing pump. Leybold lists heat treatment and furnace construction, metallurgy, large-area coating including architectural glass, load-lock chambers, high-speed food packaging, the evacuation of lamps, and crystal pulling systems for the semiconductor and solar industries as typical applications.Variants of the RUVAC WAU 2001
The RUVAC WAU 2001 is available from Ehrler & Beck in seven variants (part numbers 11751, 11751T, 11751TE, 11322, 11322TE, 11851, 11851TE). The motor power of all versions with motor is 7.5 kW at 50 and 60 Hz; the mains voltage ranges from 200–240 V to 380–460 V. The pump is also available without a motor for customer IEC motors. The H version has an ACE vibration absorber.Features of the RUVAC WA/WAU
- Air-cooled, flange-mounted three-phase standard motor of efficiency class IE3, easily exchangeable for customer motors
- Shaft seals and elastomer seals made of FPM (FKM); seals and their housing easy to replace
- WAU: integrated pressure equalisation line as overload protection at high pressures
- Supplied for vertical pumping direction; conversion to horizontal pumping direction possible by the customer
- LEYBONOL LVO 130 lubricant, filling supplied separately; inlet flange with seal and dirt trap
- ATEX category 3i (inside) as standard, valid only for 50 Hz operation
| Pumping speed 50Hz | 1,850 |
|---|---|
| Pumping speed 60Hz | 2,100 |
| Ultimate pressure | 0.04 |
| Weight | 452 |
| Length | 127.7 |
| Width | 63.8 |
| Height | 53 |
| Inlet connection flange | DN 160 ISO-K |
| Outlet connection flange | DN 160 ISO-K |
| Noise level | 80 dB(A) |
| Cooling method | Air cooling |
| Oil type | LEYBONOL LVO 130 |
Additional technical data
| Technical data | Value |
|---|---|
| Nominal pumping speed | 2050 m³/h (50 Hz) / 2460 m³/h (60 Hz) |
| Max. effective pumping speed | 1850 m³/h (50 Hz) / 2100 m³/h (60 Hz) with backing pump SOGEVAC SV 630 BF |
| Ultimate partial pressure | < 8 × 10⁻³ mbar |
| Ultimate total pressure | < 4 × 10⁻² mbar (with backing pump SOGEVAC SV 630 BF) |
| Cut-in pressure | Start at atmospheric pressure possible (pressure equalisation line) |
| Max. permissible pressure difference in continuous operation | 50 mbar |
| Leak rate, integral | ≤ 5 × 10⁻⁴ mbar·l/s |
| Version | without motor, prepared for IEC standard motor |
| Nominal pump speed 50 / 60 Hz | 3000 / 3600 min⁻¹ |
| Max. permissible speed | 3600 min⁻¹ |
| Oil filling bearing chamber, vertical pumping direction | 4.2 l (initial filling) / 3.6 l |
| Oil filling bearing chamber, horizontal pumping direction | 2.0 l (initial filling) / 1.8 l |
| Oil filling shaft seal housing | 1.6 l |
| Lubricant | LEYBONOL LVO 130 |
| Connection flanges | DN 160 ISO-K (pump flange PN 6 to DIN 2501 with collar flange) |
| Noise level | < 80 dB(A) at operating pressure < 0.1 mbar |
| Permissible ambient temperature | 12 to 40 °C |
| Materials (in contact with gas) | Carbon steel, crNi steel, grey cast iron, FPM (FKM) |
| ATEX | Category 3i (inside), only for 50 Hz operation |
| Product name | Part number |
|---|---|
| Shaft seal replacement kit RUVAC WA/WAU 1001/2001 | EK110002662 |
| Major service kit RUVAC WAU 2001 | EK110002670 |
| Seal kit RUVAC WA/WAU(H) 2001 | 19472 |
| Product name | Part number |
|---|---|
| Loose flange with retaining ring DN 160 ISO-K (required for ISO-K connection) | 26751T |
| Temperature sensor Pt 100 | 155010 |
| Oil drain facility M 16 x 1.5 with straight drain coupling | 19002 |
| Oil drain facility M 16 x 1.5 with 90° drain coupling | 20014271 |
| Pressure switch PS 115 (stainless steel), adjustable | 16004 |
| Pressure switch adjustment | 16005 |
| Adapter M 16 x 1.5 – DN 16 KF (for PS 115) | 16840 |
| Elbow 90° DN 16 ISO-KF | 18436 |
| Centring ring Al with CR (neoprene) O-ring, DN 16 ISO-KF | 18326 |
| Clamping ring Al (ADC 12), DN 10/16 ISO-KF | 18341 |
| Switching amplifier SV 110, 230 V | 16078 |
| ACE vibration absorber | 10022 |
| Frequency converter LEYTRONIC | 14111000A004DGN |
| Frequency converter LEYTRONIC | 14111000A003DGN |
| LEYBONOL LVO 130, 1 litre | L13001 |
| LEYBONOL LVO 130, 5 litres | L13005 |
| LEYBONOL LVO 130, 20 litres | L13020 |
| LEYBONOL LVO 130, 208 litres | L13099 |