SV 200/2Pumping speed 90 m³/hSV 130/2 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz, UL/CSA, 0.75 kW
The Becker SV 130/2 is a two-stage side channel blower for vacuum and pressure: 70 m³/h at 50 Hz (85 m³/h at 60 Hz), depending on the motor and mains frequency down to −400 mbar in suction operation and up to +400 mbar in pressure operation. Oil-free and contact-free compression. Ehrler & Beck advises on the right motor version.
Request a quote for this product Read more
- Pumping speed 70 m³/h 50 Hz 85 m³/h 60 Hz
- Rated motor power 0.75 kW 50 Hz 0.9 kW 60 Hz
| Motor variant | Motor order number |
|---|---|
| 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz, UL/CSA, 0.55 kW | 41489201601000TA |
| 3Ph 230/460, 208 V 60 Hz, UL/CSA, 0.66 kW at 60 Hz | 41589207601000TA |
| 3Ph 200/350 V 50 Hz / 220/380–400, 200/350 V 60 Hz, UL/CSA, 0.55 kW | 41489285601000TA |
| 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz, UL/CSA, 0.75 kW (selected) | 41689201601000TA |
| 3Ph 230/460, 208 V 60 Hz, UL/CSA, 0.9 kW at 60 Hz | 41789207601000TA |
| 3Ph 200/350 V 50 Hz / 220/380–400, 200/350 V 60 Hz, 0.75 kW | 41689285601000TA |
| 1Ph 230 V 50/60 Hz, UL/CSA, 0.75 kW | 41629227601000TA |
| 3Ph 230/400 V 50 Hz / 265/460, 230/400 V 60 Hz, UL/CSA, 1.1 kW | 41889201601000TA |
| 3Ph 230/460, 208 V 60 Hz, UL/CSA, 1.3 kW at 60 Hz | 41989207601000TA |
| 3Ph 200/350 V 50 Hz / 220/380–400, 200/350 V 60 Hz, UL/CSA, 1.1 kW | 41889285601000TA |
| 1Ph 230 V 50/60 Hz, UL/CSA, 1.1 kW | 41829227602000GZ |
Becker SV 130/2 – two-stage side channel blower for vacuum and pressure
The SV 130/2 delivers 70 m³/h at 50 Hz and 85 m³/h at 60 Hz. Becker supplies it with various motors (0.55 kW, 0.75 kW, 1.1 kW at 50 Hz); depending on the motor and mains frequency it reaches down to −400 mbar relative in suction operation and up to +400 mbar relative in pressure operation. Width × height 264 × 309 mm, suction and pressure connection G 1 1/2". The values for each motor are given in the technical data.Contact-free compression
In a side channel blower an impeller rotates in the housing without contact. The blower works without oil, with little wear and little maintenance. The two-stage design reaches higher pressure differences than the single-stage design at a lower volume flow.Advice and service
Ehrler & Beck supports you in selecting size and motor, supplies accessories and spare parts and carries out maintenance and repair.| Pumping speed 50Hz | 70 |
|---|---|
| Pumping speed 60Hz | 85 |
| Rated motor power 50Hz | 0.75 |
| Rated motor power 60Hz | 0.9 |
| Motor efficiency class | IE3 |
| Weight | 22.5 |
| Length | 38.55 |
| Width | 26.4 |
| Height | 30.9 |
| Inlet connection flange | G 1 1/2" |
| Outlet connection flange | G 1 1/2" |
| Noise level | 60.4 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Further technical data
| Motor | Data |
|---|---|
| Motor order number | 41689201601000TA |
| Pump types according to Becker | SV 130/1 + SV 130/2 |
| Phases | 3~ (three-phase) |
| 50 Hz | 0.75 kW (1.0 hp) · Δ230/Y400 V · IE3 · 2888 min⁻¹ · 2.7/1.55 A |
| 60 Hz | 0.9 kW (1.2 hp) · Δ265/Y460 V · IE3 · 3503 min⁻¹ · 2.7/1.57 A 0.9 kW (1.2 hp) · Δ230/Y400 V · IE3 · 3460 min⁻¹ · 3.0/1.76 A |
| Version | CE • UL • CSA • CC IP55 • ISO F • PTO |
| Motor length M1 | 251.0 mm |
| Overall length with this motor | 385.5 mm (Becker: overall length = L1 with motor or L2 without motor, whichever is greater; L1 with this motor 384 mm, L2 385.5 mm) |
| Performance with this motor size (50 / 60 Hz, data sheet) | Vacuum down to −270 / −250 mbar, pressure up to +250 / +230 mbar, 60.4 / 59.6 dB(A) in suction operation, 22.5 kg with motor |
| Motor data according to | Becker Motor Specifications for Pumps and Blowers (09/2026), item 11-07 |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Side channel blower, two-stage, contact-free compression, air-cooled – as vacuum pump or compressor |
| Volume flow 50 Hz / 60 Hz | 70 / 85 m³/h |
| Motor 0.55 / 0.66 kW (50 / 60 Hz) | Vacuum down to −170 / −150 mbar, pressure up to +160 / +140 mbar, 57.3 / 59.0 dB(A) in suction operation, 21.5 kg with motor, length 385.5 mm |
| Motor 0.75 / 0.9 kW (50 / 60 Hz) | Vacuum down to −270 / −250 mbar, pressure up to +250 / +230 mbar, 60.4 / 59.6 dB(A) in suction operation, 22.5 kg with motor, length 385.5–400 mm |
| Motor 1.1 / 1.29 kW (50 / 60 Hz) | Vacuum down to −380 / −400 mbar, pressure up to +400 / +390 mbar, 59.8 / 62.7 dB(A) in suction operation, 23.0 kg with motor, length 387–423 mm |
| Vacuum safety valve | With the vacuum safety valve the maximum setting is −330 mbar (1.1 kW motor: −380 mbar without valve). |
| Width × height | 264 × 309 mm |
| Suction and pressure connection | G 1 1/2" |
| Sound pressure level | Emission sound pressure level to DIN EN ISO 11203, 1 m distance, medium pressure load |
| Reference data | 1000 mbar, 20 °C, tolerance ±10 % |