ECODRY 25 plusPumping speed 25 m³/hUltimate pressure 0.01 mbar
ECODRY 65 He plus 161065V31 1Ph 100-120 V 50/60 Hz
The Leybold ECODRY 65 He plus is the helium-tight version of the ECODRY 65 plus: 55 m³/h for air, 52 m³/h for helium, leak rate below 5 × 10⁻⁸ mbar·l/s, without gas ballast. Ehrler & Beck supplies the ECODRY 65 He plus in two variants with matching accessories and service.
Request a quote for this product Read more
- Pumping speed 55 m³/h 50 Hz 55 m³/h 60 Hz
- Ultimate pressure 0.03 mbar
- Rated motor power 1.2 kW 50 Hz 1.2 kW 60 Hz
| Variant | Part number |
|---|---|
| 1Ph 200-240 V 50/60 Hz | 161065V32 |
| 1Ph 100-120 V 50/60 Hz (selected) | 161065V31 |
Leybold ECODRY 65 He plus – for helium recovery and closed circuits
The ECODRY 65 He plus is based on the ECODRY 65 plus and is optimised for permanent gases such as nitrogen, helium-3, helium-4, argon and neon – in certain set-ups also for SF₆. It achieves 55 m³/h for air and 52 m³/h for helium with an ultimate pressure below 0.03 mbar. Dimensions (623 × 320 × 298 mm), weight (around 43 kg) and flanges (DN 40 ISO-KF / DN 16 ISO-KF) are the same as on the ECODRY 65 plus.Tested leak-tightness
Leybold specifies a leak rate below 5 × 10⁻⁸ mbar·l/s, confirmed by an integral leak test; each pump is supplied with a certificate confirming that it passed the test. This version deliberately does without a gas ballast – it would be a potential leak point and a source of unwanted gas contamination.Typical applications
Helium recovery and recirculation in closed systems, cryostats, dilution refrigerators, leak detection and superconducting magnets.Variants of the ECODRY 65 He plus
The ECODRY 65 He plus is available from Ehrler & Beck in two variants (part numbers 161065V32, 161065V31). The rated power is 1.2 kW for all variants (0.6 kW at ultimate pressure); the mains voltage ranges from 100–120 V to 200–240 V (50/60 Hz, 1-phase). The weight is around 43 kg.Features of the ECODRY plus series
- Oil-free and clean: no oil, no particles, no dust in the pumping chamber; no odours
- Quiet: 52 dB(A) – below the level of a conversation
- Low maintenance: according to Leybold, up to five years without oil change or seal replacement
- Energy-efficient: 600 W power consumption at ultimate pressure, little waste heat
- Compact and mobile: small footprint, 1-phase mains connection
- Networkable: X104 interface (RS485) for monitoring and remote control
| Pumping speed 50Hz | 55 |
|---|---|
| Pumping speed 60Hz | 55 |
| Ultimate pressure | 0.03 |
| Rated motor power 50Hz | 1.2 |
| Rated motor power 60Hz | 1.2 |
| Weight | 43 |
| Length | 62.3 |
| Width | 32 |
| Height | 29.8 |
| Inlet connection flange | DN 40 ISO-KF (NW40) |
| Outlet connection flange | DN 16 ISO-KF (NW16) |
| Noise level | 52 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Convert units: vacuum and pressure units · Nm³/h to m³/h
Additional technical data
| Technical data | Value |
|---|---|
| Max. pumping speed air (without gas ballast) | 55 m³/h |
| Max. pumping speed helium (without gas ballast) | 52 m³/h |
| Ultimate pressure without gas ballast | < 0.03 mbar |
| Gas ballast | none (helium-tight version) |
| Max. permissible inlet pressure | 1050 mbar (above 2000 m installation altitude, max. 50 mbar continuously) |
| Max. permissible exhaust pressure (relative) | 200 mbar |
| Helium leak rate | < 5 × 10⁻⁸ mbar·l/s (ISO 20485, method A.1, integral) |
| Rated power | 1200 W |
| Power consumption at ultimate pressure | 600 W |
| Mains voltage | 100-120 V ± 10 %, 50/60 Hz, 1-phase |
| Rated current | 15 A |
| Mains connection | IEC 60320 C20 (mains cable required, not included) |
| Rotational speed | 12600 min⁻¹ |
| Cooling | Air |
| Noise level at ultimate pressure (DIN EN ISO 2151) | < 52 dB(A) |
| IP protection class | IP 42 |
| Permissible ambient temperature | +5 to +40 °C |
| Relative humidity | 95 %, non-condensing |
| Installation altitude, max. | 3000 m |
| Leakage current (IEC 61010-1) | < 3.5 mA |
| Certifications | CE, NRTL (cTUVus), RoHS |
| Product name | Part number |
|---|---|
| Major service kit ECODRY 40/65 plus | EK110003500 |
| Fixed castor, 2 pieces | ES6527458 |
| Product name | Part number |
|---|---|
| Mains cable EU (CEE 7/7 – C19), 2 m | 161810EU |
| Mains cable UK (BS 1363 – C19), 2 m | 161810UK |
| Mains cable USA 115 V (NEMA 5-15P – C19), 2 m | 141103US |
| Mains cable USA 230 V (NEMA 6-15P – C19), 2.5 m | 161810US |
| Mains cable China/Australia (AS 3112 – C19), 2 m | 161810CN |
| Mounting kit ECODRY 40/65 plus | 161831A |
| RS485/USB interface cable for X104, 1.8 m | 161820USB |
| Replacement jumper plug for control interface X1 | 161823A |
| Hose adapter DN 16 ISO-KF – 12 mm for the exhaust flange | 18290 |
| THERMOVAC TTR 91 RN, DN 16 KF | 21L1011100 |
| Inlet screen DN 40 ISO-KF | E41170121 |