How can we help you? Do you have questions about our products, spare parts or services? Send us your enquiry – our team will get back to you as soon as possible.
The Edwards EH1200 is a Roots pump (Roots booster) with a pumping capacity of 1195 m³/h at 50 Hz (1435 m³/h at 60 Hz). The hydrokinetic drive allows operation from atmospheric pressure without a pressure switch or bypass. Ehrler & Beck advises on selection, backing pump and service.
FX (PFPE-prepared): 3Ph 200/380 V 60 Hz, IE3 (Asia) (selected)
A30508934
Edwards EH1200 – Roots pump with hydrokinetic drive
The EH1200 belongs to Edwards' EH series of mechanical boosters (250 to 4200 m³/h). It has a pumping capacity of 1195 m³/h at 50 Hz and 1435 m³/h at 60 Hz and is combined with a suitable backing pump to improve the pumping speed and ultimate pressure of a system. The motor delivers 3 kW; the pump weighs 155 kg and is water-cooled.
Hydrokinetic drive
The motor drives one of the rotors via a fluid coupling. At a high gas load the speed of the rotors drops; as the gas load decreases they accelerate to full speed. The pump can thus be operated from atmospheric pressure over the whole vacuum range without overloading the motor – pressure switches, bypass lines or frequency converters are not needed. This limits the differential pressure across the pump, on the EH1200 to 0–90 mbar at 50 Hz and 0–75 mbar at 60 Hz.
Typical applications
Edwards names, among others, semiconductor manufacturing, thin-film coating, vacuum impregnation, vacuum distillation, vacuum metallurgy, oil drying and degassing, vacuum packaging, low-density wind tunnels, pharmaceutical freeze drying, steel degassing, space simulation and CO₂ lasers.
Versions of the Edwards EH1200
The EH1200 is available as an HC version for hydrocarbon oil (oil included) and as a PFPE-prepared FX version (oil separate), each with IE3 motor for 380/400 V 50 Hz (Europe/China), 230/460 V 60 Hz (USA), 200 V 50 Hz and 200/380 V 60 Hz (Asia). The market details come from the Edwards webshop. The standard pumps are not azide-compatible, because cooling coils made of copper that come into contact with the process are fitted.
Advice and service
Ehrler & Beck supports you in selecting the right combination of backing pump and booster, supplies oil and spare parts and carries out maintenance and repair.
Pumping speed 50Hz
1,195
Pumping speed 60Hz
1,435
Rated motor power 50Hz
3
Rated motor power 60Hz
3
Motor efficiency class
IE3
Weight
155
Length
95.3
Width
38
Height
33.4
Inlet connection flange
ISO160
Outlet connection flange
ISO100
Noise level
70 dB(A)
Cooling method
Water cooling
Oil type
Ultragrade 20, XTRAGRADE ADVANCED 168
Additional technical data
Technical data
Value
Design
Roots vacuum pump with hydrokinetic drive, water-cooled
Version
FX (PFPE-prepared): 3Ph 200/380 V 60 Hz, IE3 (Asia)
Pumping capacity (displacement) 50 Hz / 60 Hz
1195 / 1435 m³/h
Max. differential pressure (limited by the hydrokinetic drive) 50 Hz / 60 Hz
0–90 / 0–75 mbar
Max. outlet pressure
1000 mbar absolute
Speed 50 Hz / 60 Hz
0–2900 / 0–3500 min⁻¹
Motor power
3 kW (50 and 60 Hz)
Motor efficiency class
IE3
Sound pressure level (1 m, < 0.1 mbar, 50 Hz)
70 dB(A); at 60 Hz or a higher inlet pressure approx. 5 dB(A) more
Mass
155 kg
Dimensions L × W × H
953 × 380 × 334 mm
Connections, inlet/outlet side
ISO160 / ISO100
Oil
XTRAGRADE ADVANCED 168 (PFPE)
Oil fillings
Gear cover 1.25 l, hydrokinetic drive/gearbox 2.4 l, shaft seal reservoir 0.125 l
Ambient temperature (operation)
−8 to 40 °C
Type of protection
IP55
Cooling water
recommended 3 l/min at 20 °C, 2–6 bar gauge, 5–35 °C, connections 3/8" BSPP (male thread); operation without cooling water possible if the inlet pressure stays below 5 mbar and pump-down takes no more than 10 minutes
Product name
Part number
Ultragrade 20, 1 litres (HC versions)
H11024015
Ultragrade 20, 4 litres (HC versions)
H11024013
Fomblin grease AR555, tube 100 g (EH250FX/EH500FX)