VX 4.10Pumping speed 10 m³/hUltimate pressure 100 mbarVX 4.40 3Ph 400 V 50 Hz / 230/460, 208, 400 V 60 Hz, UL
The Becker VX 4.40 is a dry-running rotary vane vacuum pump of the X series with a pumping speed of 40 m³/h at 50 Hz (48 m³/h at 60 Hz) and a vacuum down to 100 mbar absolute. Specially developed vanes achieve service lives of up to 20,000 operating hours. Ehrler & Beck advises on selection, accessories and service.
Request a quote for this product Read more
- Pumping speed 40 m³/h 50 Hz 48 m³/h 60 Hz
- Ultimate pressure 100 mbar
- Rated motor power 1.3 kW 50 Hz 1.5 kW 60 Hz
| Motor variant | Motor order number |
|---|---|
| 3Ph 400 V 50 Hz / 230/460, 208, 400 V 60 Hz, UL (selected) | 42184407276114IL |
| 3Ph 200/350 V 50 Hz / 220/380–400, 200/350 V 60 Hz, UL/CSA | 42084453276114IL |
| 3Ph 190–255/330–440 V 50 Hz / 190–290/330–500 V 60 Hz, IP55 | 41814498276003CY |
| 3Ph 190–255/330–440 V 50 Hz / 190–290/330–500 V 60 Hz, IP54 | 41914498276 |
| 1Ph 230 V 50/60 Hz | 41824402276 |
Becker VX 4.40 – oil-free rotary vane vacuum pump of the X series
The VX 4.40 delivers 40 m³/h at 50 Hz and 48 m³/h at 60 Hz and reaches a vacuum of 100 mbar absolute. The installed motor power is 1.25–1.3 kW at 50 Hz and 1.5 kW at 60 Hz (depending on the motor). The sound pressure level is 67 dB(A) (50 Hz) or 72 dB(A) (60 Hz), the weight with motor approx. 38–41 kg, depending on the motor. Dimensions 561 × 270–280 × 299 mm (L × W × H), suction connection G 3/4".Dry-running rotary vane principle
The pump is designed for continuous operation in the rough vacuum range. Its self-lubricating vanes run without oil – there is no oil change, and the conveyed air stays free of oil. This makes the VX 4.40 a solution for applications that require a clean environment. The operating point can be set with the integrated vacuum regulating valve.X series
For the X series Becker has developed a special vane material: the vanes achieve service lives of up to 20,000 operating hours or 3 years, and there is virtually no abrasion. Becker therefore describes the pumps as suitable for precision processes under clean-room conditions; the air flow is low in pulsation. Size, motor and connections correspond to the VT 4.40.Design and equipment
The motor drives the rotor directly via the motor shaft – this keeps the pump compact and makes installation easier. The robust design is intended for long running times even under demanding conditions, and maintenance can be carried out on site.- Large integrated inlet filter
- Combined vacuum regulating and safety valve
- Noise-optimised blow-off valve
- Base with vibration dampers
Versions and accessories
- External inlet filter: accessory, on request
- Acoustic hood SH 19: accessory, on request
- Further combinations: on request
Advice and service
Ehrler & Beck supports you in selecting the right size, supplies accessories and spare parts and carries out maintenance and repair.| Pumping speed 50Hz | 40 |
|---|---|
| Pumping speed 60Hz | 48 |
| Ultimate pressure | 100 |
| Rated motor power 50Hz | 1.3 |
| Rated motor power 60Hz | 1.5 |
| Motor efficiency class | IE3 |
| Weight | 41 |
| Length | 56.1 |
| Width | 28 |
| Height | 29.9 |
| Inlet connection flange | G 3/4" |
| Noise level | 67 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Further technical data
| Motor | Data |
|---|---|
| Motor order number | 42184407276114IL |
| Pump types according to Becker | VT/VX 4.40 |
| Phases | 3~ (three-phase) |
| 50 Hz | 1.3 kW (1.7 hp) · Y400 V · IE3 · 1435 min⁻¹ · 3.1 A |
| 60 Hz | 1.5 kW (2.0 hp) · YY230/Y460 V · IE3 · 1735 min⁻¹ · 5.8/2.9 A 1.5 kW (2.0 hp) · YY208 V · IE3 · 1720 min⁻¹ · 6.5 A 1.5 kW (2.0 hp) · Y400 V · 1715 min⁻¹ · 3.3 A |
| Version | CE • UL • CC IP55 • ISO F • PTO |
| Motor data according to | Becker Motor Specifications for Pumps and Blowers (09/2026), item 2-17 |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Rotary vane vacuum pump, dry-running (oil-free), air-cooled |
| Pumping speed 50 Hz / 60 Hz | 40 / 48 m³/h |
| Vacuum (absolute) | 100 mbar |
| Installed motor power 50 Hz / 60 Hz | 1.25–1.3 / 1.5 kW |
| Sound pressure level 50 Hz / 60 Hz | 67 / 72 dB(A) (DIN EN ISO 3744, 1 m) |
| Weight with motor | approx. 38–41 kg (depending on the motor) |
| Dimensions L × W × H | 561 × 270–280 × 299 mm (with eye bolt; housing 253 mm) |
| Suction connection | G 3/4" |
| Reference data | 1000 mbar, 20 °C, tolerance ±5 % |
| Vane service life (X series) | up to 20,000 operating hours or 3 years |
| Version / accessory | Description |
|---|---|
| External inlet filter | Accessory, on request |
| Sound enclosure SH 19 | Accessory, on request |
| Further combinations | on request |