SCROLLVAC 3 plusPumping speed 3 m³/hUltimate pressure 0.1 mbar
SCROLLVAC 7 plus 3Ph 200/380-415 V 50 Hz, 200-230/460 V 60 Hz, H version
The Leybold SCROLLVAC 7 plus is an oil-free, air-cooled scroll vacuum pump with 6.1 m³/h maximum pumping speed and an ultimate pressure of 0.02 mbar. It is the smallest pump of sizes 7 to 18 plus and operates at less than 55 dB(A). Ehrler & Beck supplies the SCROLLVAC 7 plus in six variants with matching accessories, spare parts and service.
Request a quote for this product Read more
- Pumping speed 5.1 m³/h 50 Hz 6.1 m³/h 60 Hz
- Ultimate pressure 0.02 mbar
- Rated motor power 0.26 kW 50 Hz 0.26 kW 60 Hz
| Variant | Part number |
|---|---|
| 1Ph 100-127/200-240 V 50/60 Hz | 141007V10 |
| 1Ph 100-127/200-240 V 50/60 Hz, H version | 141007V11 |
| 1Ph 100-127/200-240 V 50/60 Hz, C version | 141007V12 |
| 3Ph 200/380-415 V 50 Hz, 200-230/460 V 60 Hz | 141007V30 |
| 3Ph 200/380-415 V 50 Hz, 200-230/460 V 60 Hz, H version (selected) | 141007V31 |
| 3Ph 200/380-415 V 50 Hz, 200-230/460 V 60 Hz, C version | 141007V32 |
Leybold SCROLLVAC 7 plus – dry backing pump for small gas loads
The SCROLLVAC 7 plus achieves a maximum pumping speed of 6.1 m³/h and an ultimate pressure of 0.02 mbar with the gas ballast closed. At ultimate pressure it draws 260 W, weighs 26 kg and is equipped with DN 25 ISO-KF inlet and outlet flanges. With gas ballast it pumps up to 100 g/h of water vapour.Oil-free and low-maintenance
The scroll principle works without oil in the pumping chamber; maintenance essentially concerns the tip seals, for which Leybold offers a minor service kit. For continuous operation, Leybold specifies a maximum inlet pressure of 200 mbar and a recommended chamber volume of up to 25 litres for pumping down from atmospheric pressure.Typical applications
Backing pump for turbomolecular pumps, analytics and laboratory, research institutions and clean industrial applications in which no oil may enter the process.Variants of the SCROLLVAC 7 plus
The SCROLLVAC 7 plus is available from Ehrler & Beck in six variants (part numbers 141007V10, 141007V11, 141007V12, 141007V30, 141007V31, 141007V32): as standard, H and C versions, each with a 1-phase or 3-phase motor. The power consumption at ultimate pressure is 0.26 kW for all variants and the weight 26 kg; the pumping speed ranges from 5.1 m³/h (3-phase at 50 Hz) to 6.1 m³/h.Features of the SCROLLVAC 7 to 18 plus
- Oil-free: dry scroll principle, no oil in the pumping chamber
- Quiet: less than 55 dB(A), low vibration (below 4.5 mm/s)
- Leak-tight: leak rate 1 × 10⁻⁶ mbar·l/s
- Three versions: standard with gas ballast, H without gas ballast, C for aggressive applications
- Single- or three-phase: 100–127 V / 200–240 V or 200 / 380–415 V (50 Hz) or 200–230 / 460 V (60 Hz)
- Certified: ATEX II 3 G Ex h IIC T4 Gc X (internal atmosphere only)
| Pumping speed 50Hz | 5.1 |
|---|---|
| Pumping speed 60Hz | 6.1 |
| Ultimate pressure | 0.02 |
| Rated motor power 50Hz | 0.26 |
| Rated motor power 60Hz | 0.26 |
| Weight | 26 |
| Length | 43.2 |
| Width | 29.8 |
| Height | 31.2 |
| Inlet connection flange | DN 25 ISO-KF (NW25) |
| Outlet connection flange | DN 25 ISO-KF (NW25) |
| Noise level | 55 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Additional technical data
| Technical data | Value |
|---|---|
| Max. pumping speed | 5.1 m³/h (50 Hz) / 6.1 m³/h (60 Hz) |
| Ultimate pressure with gas ballast closed | 7 × 10⁻² mbar (50 Hz) / 2 × 10⁻² mbar (60 Hz) |
| Version | H version without gas ballast |
| Power consumption at ultimate pressure | 260 W |
| Mains voltage | 200 V / 380-415 V, 50 Hz or 200-230 V / 460 V, 60 Hz, 3-phase |
| Input current | 2.4 A (200 V or 200-230 V) / 1.5 A (380-415 V or 460 V) |
| Speed at full load | 1500 min⁻¹ (50 Hz) / 1800 min⁻¹ (60 Hz) |
| Max. continuous inlet pressure | 200 mbar |
| Recommended chamber volume from atmospheric pressure, max. | 25 l |
| Max. outlet pressure | 0.5 bar (gauge pressure) |
| Leak rate | 1 × 10⁻⁶ mbar·l/s |
| Noise level at ultimate pressure | < 55 dB(A) |
| Vibration at the inlet (ISO 20816-1) | < 4.5 mm/s |
| Cooling | Air (fan) |
| Permissible ambient temperature | +5 to +40 °C |
| Relative humidity in operation | 10 to 90 % |
| Installation altitude, max. | 2000 m |
| Certification | ATEX II 3 G Ex h IIC T4 Gc X (internal atmosphere only) |
| Product name | Part number |
|---|---|
| Minor service kit SCROLLVAC 7/10/15 plus (tip seals) | EK117141000 |
| Minor service kit SCROLLVAC 7/10/15 C plus | EK117141002 |
| Bearing replacement kit SCROLLVAC 7-18 plus | EK117141004 |
| Silencer spares kit (for 141102A02) | EK117141005 |
| Spares kit rear bearing / bearing housing | A73501712 |
| Product name | Part number |
|---|---|
| Mains cable EU (CEE 7/7 – C19), 2 m | 161810EU |
| Mains cable UK (BS 1363 – C19), 2 m | 161810UK |
| Mains cable USA 115 V (NEMA 5-15P – C19), 2 m | 141103US |
| Mains cable USA 230 V (NEMA 6-15P – C19), 2.5 m | 161810US |
| Gas ballast blank plug | 141100A01 |
| Purge gas adapter with fine restriction (quick connect 1/4") | 141100A03 |
| Purge gas adapter without restriction (quick connect 1/4") | 141100A02 |
| Vibration isolators SCROLLVAC 7, 10, 15, 18 plus | 141102A01 |
| Exhaust silencer SCROLLVAC 7, 10, 15, 18 plus | 141102A02 |
| Centring ring stainless steel with O-ring FKM, DN 25 ISO-KF | 88347 |
| Centring ring Al with O-ring FKM, DN 25 ISO-KF | 18207 |
| Clamping ring Al (ADC 12), DN 20/25 ISO-KF | 18342 |
| THERMOVAC TTR 91 RN, DN 16 KF | 21L1011100 |
| C conversion kit (SCROLLVAC 7/10/15 plus) | 141101A01 |