SCROLLVAC 3 plusPumping speed 3 m³/hUltimate pressure 0.1 mbar
SCROLLVAC 15 plus 1Ph 100-127/200-240 V 50/60 Hz, C version
The Leybold SCROLLVAC 15 plus is an oil-free, air-cooled scroll vacuum pump with 14.5 m³/h maximum pumping speed, 0.009 mbar ultimate pressure and the highest water vapour capacity in the series (280 g/h). Ehrler & Beck supplies the SCROLLVAC 15 plus in six variants with matching accessories, spare parts and service.
Request a quote for this product Read more
- Pumping speed 14.5 m³/h 50 Hz 14.5 m³/h 60 Hz
- Ultimate pressure 9 × 10-3 mbar
- Rated motor power 0.3 kW 50 Hz 0.3 kW 60 Hz
| Variant | Part number |
|---|---|
| 1Ph 100-127/200-240 V 50/60 Hz | 141015V10 |
| 1Ph 100-127/200-240 V 50/60 Hz, H version | 141015V11 |
| 1Ph 100-127/200-240 V 50/60 Hz, C version (selected) | 141015V12 |
| 3Ph 200/380-415 V 50 Hz, 200-230/460 V 60 Hz | 141015V30 |
| 3Ph 200/380-415 V 50 Hz, 200-230/460 V 60 Hz, H version | 141015V31 |
| 3Ph 200/380-415 V 50 Hz, 200-230/460 V 60 Hz, C version | 141015V32 |
Leybold SCROLLVAC 15 plus – the scroll pump for humid processes
The SCROLLVAC 15 plus combines 14.5 m³/h maximum pumping speed with an ultimate pressure of 0.009 mbar. With gas ballast it handles up to 280 g/h of water vapour – more than any other size in the series. Power consumption at ultimate pressure 300 W, weight 26 kg, flanges DN 25 ISO-KF.Three versions for different media
Besides the standard version with gas ballast, there is the H version without gas ballast – useful, for example, for noble gas recirculation or gas recovery, because a potential leak point is eliminated – and the C version with more chemically resistant materials for aggressive applications. A conversion kit turns a standard pump into a C version retroactively.Typical applications
Drying and degassing processes in the laboratory, backing pump for turbomolecular pumps, analytical instruments and clean industrial processes.Variants of the SCROLLVAC 15 plus
The SCROLLVAC 15 plus is available from Ehrler & Beck in six variants (part numbers 141015V10, 141015V11, 141015V12, 141015V30, 141015V31, 141015V32): as standard, H and C versions, each with a 1-phase or 3-phase motor. The power consumption at ultimate pressure is 0.3 kW for all variants and the weight 26 kg; the pumping speed ranges from 12.6 m³/h (3-phase at 50 Hz) to 14.5 m³/h.Features of the SCROLLVAC 7 to 18 plus
- Oil-free: dry scroll principle, no oil in the pumping chamber
- Quiet: less than 55 dB(A), low vibration (below 4.5 mm/s)
- Leak-tight: leak rate 1 × 10⁻⁶ mbar·l/s
- Three versions: standard with gas ballast, H without gas ballast, C for aggressive applications
- Single- or three-phase: 100–127 V / 200–240 V or 200 / 380–415 V (50 Hz) or 200–230 / 460 V (60 Hz)
- Certified: ATEX II 3 G Ex h IIC T4 Gc X (internal atmosphere only)
| Pumping speed 50Hz | 14.5 |
|---|---|
| Pumping speed 60Hz | 14.5 |
| Ultimate pressure | 9 × 10-3 |
| Rated motor power 50Hz | 0.3 |
| Rated motor power 60Hz | 0.3 |
| Weight | 26 |
| Length | 43.2 |
| Width | 29.8 |
| Height | 31.2 |
| Inlet connection flange | DN 25 ISO-KF (NW25) |
| Outlet connection flange | DN 25 ISO-KF (NW25) |
| Noise level | 55 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Additional technical data
| Technical data | Value |
|---|---|
| Max. pumping speed | 14.5 m³/h (50/60 Hz) |
| Ultimate pressure with gas ballast closed | 9 × 10⁻³ mbar |
| Ultimate pressure with gas ballast (position 1) | 4 × 10⁻² mbar |
| Gas ballast flow (position 1) | 14 l/min |
| Water vapour capacity with gas ballast | 280 g/h |
| Version | C version for aggressive applications, with gas ballast |
| Power consumption at ultimate pressure | 300 W |
| Mains voltage | 100-127 V or 200-240 V ± 10 %, 50/60 Hz, 1-phase |
| Input current | 10 A (100-127 V) / 6 A (200-240 V) |
| Mains connection | IEC EN60320 C19 (mains cable required, see accessories) |
| Speed at full load | 1800 min⁻¹ |
| Max. continuous inlet pressure | 200 mbar |
| Recommended chamber volume from atmospheric pressure, max. | 75 l |
| Max. outlet pressure | 0.5 bar (gauge pressure) |
| Leak rate | 1 × 10⁻⁶ mbar·l/s |
| Noise level at ultimate pressure | < 55 dB(A) |
| Vibration at the inlet (ISO 20816-1) | < 4.5 mm/s |
| Cooling | Air (fan) |
| Permissible ambient temperature | +5 to +40 °C |
| Relative humidity in operation | 10 to 90 % |
| Installation altitude, max. | 2000 m |
| Certification | ATEX II 3 G Ex h IIC T4 Gc X (internal atmosphere only) |
| Product name | Part number |
|---|---|
| Minor service kit SCROLLVAC 7/10/15 plus (tip seals) | EK117141000 |
| Minor service kit SCROLLVAC 7/10/15 C plus | EK117141002 |
| Bearing replacement kit SCROLLVAC 7-18 plus | EK117141004 |
| Silencer spares kit (for 141102A02) | EK117141005 |
| Spares kit rear bearing / bearing housing | A73501712 |
| Product name | Part number |
|---|---|
| Mains cable EU (CEE 7/7 – C19), 2 m | 161810EU |
| Mains cable UK (BS 1363 – C19), 2 m | 161810UK |
| Mains cable USA 115 V (NEMA 5-15P – C19), 2 m | 141103US |
| Mains cable USA 230 V (NEMA 6-15P – C19), 2.5 m | 161810US |
| Gas ballast blank plug | 141100A01 |
| Purge gas adapter with fine restriction (quick connect 1/4") | 141100A03 |
| Purge gas adapter without restriction (quick connect 1/4") | 141100A02 |
| Vibration isolators SCROLLVAC 7, 10, 15, 18 plus | 141102A01 |
| Exhaust silencer SCROLLVAC 7, 10, 15, 18 plus | 141102A02 |
| Centring ring stainless steel with O-ring FKM, DN 25 ISO-KF | 88347 |
| Centring ring Al with O-ring FKM, DN 25 ISO-KF | 18207 |
| Clamping ring Al (ADC 12), DN 20/25 ISO-KF | 18342 |
| THERMOVAC TTR 91 RN, DN 16 KF | 21L1011100 |
| C conversion kit (SCROLLVAC 7/10/15 plus) | 141101A01 |