GVS 80 VSD+Pumping speed 78 m³/hUltimate pressure 0.5 mbar
GVS 400 VSD+ 3Ph 380-460 V 50/60 Hz, IEC-UL/cUL
The Atlas Copco GVS 400 VSD+ is the largest model of the GVS VSD+ range: a single-stage, oil-sealed and air-cooled rotary vane vacuum pump with integrated frequency inverter, a pumping speed of 187 to 351 m³/h, an ultimate pressure of 0.3 mbar(a) and a motor power of 11 kW. Ehrler & Beck supplies the GVS 400 VSD+ with matching spare parts, accessories and service.
Request a quote for this product Read more
- Pumping speed 351 m³/h 50 Hz 351 m³/h 60 Hz
- Ultimate pressure 0.3 mbar
- Rated motor power 11 kW 50 Hz 11 kW 60 Hz
| Variant | Part number |
|---|---|
| 3Ph 380-460 V 50/60 Hz, IEC-UL/cUL (selected) | 8153336007 |
Atlas Copco GVS 400 VSD+ – the largest model of the GVS VSD+ range
The GVS 400 VSD+ regulates its pumping speed between 187 and 351 m³/h and reaches 0.3 mbar(a) with the gas ballast closed. Its motor delivers 11 kW and runs at 1050 to 2160 rpm. Atlas Copco states dimensions of 1220 × 555 × 551 mm and a net mass of 291 kg; the inlet and the exhaust connection are G 2". The oil filling is 8.5 to 11.5 l.Central control of several pumps
In addition to operation by smartphone or PC, pressure, speed, temperature, current and operating hours can be read out and controlled via fieldbus. Atlas Copco also provides the option of centralising several pumps and controlling them together – including pressure, speed and start/stop.Applications of the range
As fields of application for the GVS VSD+, Atlas Copco lists, among others, packaging, woodworking, rubber and plastics, R&D systems, the electronics industry, conveying and goods handling, paper and printing, medical vacuum, environmental applications, modified atmosphere packaging, freeze drying and clay mouldings.Variants of the GVS 400 VSD+
The GVS 400 VSD+ is available from Ehrler & Beck in one version (part number 8153336007): IEC – UL/cUL for 380–460 V, 50/60 Hz, 3-phase. The motor power is 11 kW, the pumping speed 187 to 351 m³/h and the net mass 291 kg.Features of the GVS VSD+ range
- Design: single-stage, oil-sealed, air-cooled, direct drive
- Speed control by pressure: the integrated VSD+ frequency inverter maintains the selected pressure setpoint
- VSD+ app: commissioning, control and monitoring via Bluetooth, for Android and iOS
- Interfaces: Modbus RTU as standard, control panel on the inverter
- Protective functions: STO function, temperature protection and vacuum relief valve
- Scope of delivery: pressure sensor 0–1000 mbar(a) with T-pipe, Modbus cable M12 to USB, outlet silencer
- Options: Pt1000 temperature sensor for element protection; O2 versions for applications with a high oxygen concentration
| Pumping speed 50Hz | 351 |
|---|---|
| Pumping speed 60Hz | 351 |
| Ultimate pressure | 0.3 |
| Rated motor power 50Hz | 11 |
| Rated motor power 60Hz | 11 |
| Weight | 291 |
| Length | 122 |
| Width | 55.5 |
| Height | 55.1 |
| Inlet connection flange | G 2" female thread |
| Outlet connection flange | G 2" female thread |
| Noise level | 72 dB(A) |
| Cooling method | Air cooling |
| Oil type | VACUUM VANE FLUID PLUS 100 |
Additional technical data
| Technical data | Value |
|---|---|
| Sound pressure level (figure from the Atlas Copco shop = base pump GVS 300 A at 50 Hz) | 72 dB(A) |
| Pumping speed, variable-speed (min.–max.) | 187–351 m³/h |
| Ultimate pressure with gas ballast closed | 0.3 mbar(a) |
| Rated motor power | 11 kW |
| Mains connection | 380–460 V, 50/60 Hz, 3-phase |
| Version | IEC – UL/cUL |
| Rated current | 22.9 A |
| Imax under voltage | 25.2 A |
| Max. fuse IEC class gG/gL | 32 A |
| Recommended cable cross-section | 6 mm² (AWG 10) |
| Motor speed (min.–max.) | 1050–2160 rpm |
| Rated motor frequency | 72 Hz |
| Drive | Direct drive with frequency inverter mounted on the motor (VSD+) |
| Interfaces | Modbus RTU, Bluetooth (VSD+ app), control panel |
| Cooling | Air |
| Oil filling | 8.5 to 11.5 l |
| Oil viscosity | Mineral oil ISO VG 68; synthetic/PFPE oil ISO VG 100 |
| Standard lubricant | Vacuum Vane Fluid Plus 100 |
| Max. water vapour inlet pressure with standard gas ballast | 30 mbar(a) |
| Max. water vapour inlet pressure with large gas ballast (or 2 gas ballast valves) | 40 mbar(a) |
| Max. water vapour pumping rate with standard gas ballast | 6.5 kg/h |
| Max. inlet pressure for continuous operation | 1013 mbar(a) |
| Exhaust back pressure (min. / max.) | -15 / +150 mbar(e) |
| Ambient temperature | 12 to 40 °C |
| Gas inlet temperature | 12 to 40 °C |
| Dimensions L × W × H | 1220 × 555 × 551 mm |
| Net weight / shipping weight | 291 kg / 338 kg |
| Inlet connection / exhaust connection | G 2" / G 2" |
| Product name | Part number |
|---|---|
| Minor maintenance kit GVS 300/320A | SK9607M |
| Major maintenance kit GVS 300A, FKM | SK9607001 |
| Oil filter GVS 170-300A | 3001170192 |
| Oil separator element GVS 300-630 | 3001170186 |
| Vacuum Vane Fluid 68, mineral oil ISO VG 68, 1 litres | 1630204501 |
| Vacuum Vane Fluid 68, mineral oil ISO VG 68, 5 litres | 3002614058 |
| Vacuum Vane Fluid 68, mineral oil ISO VG 68, 20 litres | 3002614057 |
| Product name | Part number |
|---|---|
| T-type inlet filter 2 | 8092300035 |
| T-type liquid separator 2 | 8092300845 |
| Liquid separator 2" | 8092300998 |
| Cyclone pre-filter BSPP 2" | 8092301038 |
| Cyclone pre-filter BSPP 3" | 8092301046 |
| Large gas ballast GVS 300A | 8092301988 |
| Oil level switch GVS 100A & GVS 300A | 8092301780 |
| DP switch GVS 40-630A | 8092301822 |
| DP gauge GVS 40-630A | 8092302002 |
| Temperature switch GVS 40-100A & GVS 300A | 8092301830 |
| VAC 1506 / 2" | 8092300949 |
| Vacuum tank 270 L | 8092300345 |
| Vacuum tank 500 L | 8092300352 |
| Vacuum tank 1000 L | 8092300360 |
| Vacuum tank 2000 L | 8092300378 |
| Vacuum tank 3000 L | 8092300386 |
| Automatic drain AVD 230 VAC | 8092300349 |