DWS 200Pumping speed 210 m³/hUltimate pressure 0.05 mbar
DWS 500 3Ph 400 V 50 Hz (IEC, Europe/China), water-cooled
The Atlas Copco DWS 500 is a dry screw vacuum pump with a pumping speed of 460 m³/h and an ultimate pressure below 0.01 mbar. Its tapered rotors with variable pitch tolerate particles and condensate and work without oil in the pumping chamber. Ehrler & Beck supplies it with or without motor.
Request a quote for this product Read more
- Pumping speed 460 m³/h 50 Hz 460 m³/h 60 Hz
- Ultimate pressure 0.01 mbar
| Variant | Part number |
|---|---|
| 3Ph 400 V 50 Hz (IEC, Europe/China), water-cooled (selected) | 3002615083 |
| 3Ph 230/460 V 60 Hz (cUL/UL, USA), water-cooled | 3002615084 |
| 3Ph 200/380 V 50 Hz (Asia), water-cooled | 3002615085 |
| 3Ph 200/380 V 60 Hz (Asia), water-cooled | 3002615086 |
| 3Ph 575 V 60 Hz (cUL/UL, Canada), water-cooled | 3002615087 |
| without motor, for IEC motor 50 Hz (e.g. Europe), water-cooled | 3002615096 |
| without motor, for NEMA motor 60 Hz (North America), water-cooled | 3002615097 |
Atlas Copco DWS 500 – robust screw vacuum pump for industry
The DWS 500 reaches a pumping speed of up to 460 m³/h and an ultimate pressure below 0.01 mbar(a). At ultimate pressure it draws 4.6 kW, at full pumping capacity 11 kW. Dimensions 1350 × 494 × 568 mm (L × W × H), inlet DN 63 ISO-F, outlet DN 63 ISO-K.Tapered screws with variable pitch
The heart of the DWS range is two dry-running screw rotors whose profile combines parallel and tapered sections. The gas is compressed gradually along the rotors; this lowers power consumption and temperature and makes the pump insensitive to particles and liquid from the process. Shaft seal purge and gas ballast provide additional protection and extend the service intervals.Applications of the range
Atlas Copco lists the manufacture of lithium-ion batteries and solar cells, plastics extrusion, automotive painting, heat treatment and brazing, pharmaceuticals, freeze drying, the coating of industrial glass and thin-film processes.Variants of the DWS 500
The DWS 500 is available from Ehrler & Beck as a water-cooled version for the markets Europe and China (400 V 50 Hz, IEC), USA (230/460 V 60 Hz, cUL/UL), Asia (200/380 V 50 or 60 Hz) and Canada (575 V 60 Hz, cUL/UL), and also without motor with IEC motor flange (50 Hz) or NEMA motor flange (60 Hz, North America). With the matching adapter it becomes the backing pump of a DRB or ZRS booster pump.Features of the DWS range
- Tapered screw rotors with variable pitch (hybrid profile of parallel and tapered sections): high pumping capacity with a small footprint and low energy demand
- Dry, oil-free pumping chamber – no contaminated oil that has to be disposed of
- Robust water cooling system; DWS 200 and 300 also available air-cooled (indirect cooling)
- Shaft seal purge and gas ballast with atmospheric air extend the service intervals where particles and condensate are present
- Directly flanged motor, versions for all regions; also available without motor
- Dedicated accessories: silencers, non-return valves, transmitters and brackets for DRB and ZRS booster pumps
- Protection class IP54, ATEX-certified variants also available (on request)
| Pumping speed 50Hz | 460 |
|---|---|
| Pumping speed 60Hz | 460 |
| Ultimate pressure | 0.01 |
| Length | 135 |
| Width | 49.4 |
| Height | 56.8 |
| Inlet connection flange | DN 63 ISO-F |
| Outlet connection flange | DN 63 ISO-K |
| Noise level | 76 dB(A) |
| Cooling method | Water cooling |
| Oil type | PRIME 100 |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Dry screw vacuum pump with tapered variable-pitch rotors, single-stage |
| Max. pumping speed | 460 m³/h (50 and 60 Hz) |
| Ultimate pressure | < 0.01 mbar(a) |
| Power consumption at ultimate pressure / at max. pumping capacity | 4.6 / 11 kW |
| Mains connection (versions) | 3Ph 400 V 50 Hz (IEC, Europe/China), 3Ph 230/460 V 60 Hz (cUL/UL, USA), 3Ph 200/380 V 50 Hz (Asia), 3Ph 200/380 V 60 Hz (Asia), 3Ph 575 V 60 Hz (cUL/UL, Canada) |
| Sound pressure level | < 76 dB(A) |
| Cooling | Water (direct) |
| Cooling water | Connection G 1/2" female, < 8 l/min, max. 7 bar, 5 to 35 °C, min. 0.2 bar differential pressure |
| Barrier gas (purge) | Connection G 1/4" female, 2.5 to 6.9 bar, shaft seal purge < 12 l/min |
| Gas ballast | 0 to 50 l/min |
| Gear oil | Atlas Copco PRIME 100 |
| Max. exhaust back pressure | 1200 mbar(a) |
| Ambient temperature | 5 to 40 °C |
| Type of protection | IP54 |
| Dimensions L × W × H | 1350 × 494 × 568 mm |
| Inlet / outlet | DN 63 ISO-F / DN 63 ISO-K |
| Product name | Part number |
|---|---|
| Booster adapter DWS 500 to ZRS 1200/2600/4200 | 3002615102 |
| Booster adapter DWS 500 to DRB 500 | 3002615154 |
| Booster adapter DWS 500 to DRB 1000 | 3002615155 |
| Booster adapter DWS 500 to DRB 2000 | 3002615156 |
| Temperature control valve (TCV) for water-cooled pumps | 3002615103 |
| Exhaust pressure transmitter (PS1) | 3002615105 |
| Stator temperature transmitter (PT100) | 3002615106 |
| Exhaust temperature transmitter (TS3) | 3002615107 |
| BoV plug DWS 200/300/500 | 3002615108 |
| Blow-off valve kit (BoV) | 3002615109 |
| Exhaust silencer DN 63 ISO-K | 3002615181 |
| Integrated silencer DWS 500 | 3002615183 |
| Outlet check valve DWS 500 | 3002615185 |