VARIAIR KVX 3.80/0-400Pumping speed 76 m³/hUltimate pressure 100 mbar
VARIAIR KVX 3.100/0-400
The Becker VARIAIR KVX 3.100/0-400 is a dry-running rotary vane vacuum pump of the X series with integrated VARIAIR frequency converter. It delivers up to 112 m³/h, reaches 100 mbar absolute and matches the speed to the demand between 30 and 60 Hz. Ehrler & Beck advises on selection and service.
Request a quote for this product Read more
- Pumping speed 112 m³/h 50 Hz 112 m³/h 60 Hz
- Ultimate pressure 100 mbar
Becker VARIAIR KVX 3.100/0-400 – variable-speed oil-free rotary vane vacuum pump
The VARIAIR KVX 3.100/0-400 combines the dry-running KVX 3.100 with a VARIAIR frequency converter. It delivers up to 112 m³/h (at 60 Hz), reaches a vacuum of 100 mbar absolute and works in a frequency range of 30 to 60 Hz. The converter is supplied with 400–480 V ±10 % at 50 or 60 Hz (max. 16 A). Sound pressure level 77 dB(A) (at −600 mbar, 40 Hz), weight with motor and converter 109.5 kg, dimensions 829 × 470 × 400 mm (L × W × H), suction connection G 1 1/2".VARIAIR converter technology
The frequency converter matches the pump's output to the process: instead of running at a fixed speed, the pump delivers exactly the pumping speed that is needed. This optimises the energy demand and keeps the vacuum constant even when demand fluctuates.Dry-running and robust
Like all KVX pumps, the VARIAIR KVX 3.100/0-400 works without oil in the pumping chamber; there are no oil changes. The robust design is intended for long running times, and noise-reducing measures ensure quiet operation. The vanes of the X series achieve service lives of up to 20,000 operating hours or 3 years.Advice and service
Ehrler & Beck supports you in sizing, supplies accessories and spare parts and carries out maintenance and repair.| Pumping speed 50Hz | 112 |
|---|---|
| Pumping speed 60Hz | 112 |
| Ultimate pressure | 100 |
| Weight | 109.5 |
| Length | 82.9 |
| Width | 47 |
| Height | 40 |
| Inlet connection flange | G 1 1/2" |
| Noise level | 77 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Additional technical data
| Technical data | Value |
|---|---|
| Design | Rotary vane vacuum pump, dry-running (oil-free), air-cooled, with VARIAIR frequency converter, X series |
| Max. pumping speed | 112 m³/h |
| Max. vacuum (absolute) | 100 mbar |
| Frequency range | 30–60 Hz |
| Frequency converter | VARIAIR frequency converter VAU4/4, 4.0 kW |
| Mains connection | 400–480 V ±10 %, 50/60 Hz, max. 16 A |
| Sound pressure level | 77 dB(A) (at −600 mbar, 40 Hz) |
| Weight with motor and converter | 109.5 kg |
| Dimensions L × W × H | 829 × 470 × 400 mm |
| Suction connection | G 1 1/2" |
| Reference data | 1000 mbar, 20 °C, tolerance ±5 % |
| Vane service life (X series) | up to 20,000 operating hours or 3 years |