U 4.70

Series: U4 series Manufacturer: Becker Technology: Oil-lubricated rotary vane vacuum pumps

Outdated product This model is no longer part of the manufacturer's current range.

Current alternative: U 5.65 (XL K)

The Becker U 4.70 is an oil-lubricated, air-cooled rotary vane vacuum pump with a pumping speed of 63 m³/h at 50 Hz (74 m³/h at 60 Hz). Becker offered it as SA/K with an ultimate pressure of 3 mbar and as F/K with 0.5 mbar. The model is no longer part of the current Becker range. For pumps in service, Ehrler & Beck supports you with service and with the selection of a current model.

Request a quote for this product Read more

  • Pumping speed 63 m³/h 50 Hz 74 m³/h 60 Hz
  • Ultimate pressure 0.5 mbar
  • Rated motor power 2.4 kW 50 Hz 3 kW 60 Hz

Becker U 4.70 – outdated model

Becker no longer lists the U 4.70 in its current range: its documents are in the archive of the Becker download centre, and the Becker product range catalogue 01/2026 lists only the U 4.400 and the U 4.630 in the U 4 series. Becker names no successor. In the Ehrler & Beck range, the Becker U 5.65 (XL K) is the nearest in size, with 65 m³/h at 50 Hz and an ultimate pressure of 0.5 mbar.

Technical data

According to the Becker data sheet of 02.07.2014, the U 4.70 delivers 63 m³/h at 50 Hz and 74 m³/h at 60 Hz (tolerance ±5 %); the ultimate pressure is 3 mbar (SA/K) or 0.5 mbar (F/K) absolute. The three-phase motor has a power of 2.4 kW at 50 Hz and 3.0 kW at 60 Hz (efficiency class IE2). Sound pressure level 67 / 68.5 dB(A) at 50 / 60 Hz. The pump weighs 34 kg without motor; the motor weighs 26 or 29 kg. Overall length with motor 715 or 720 mm, width 374 mm, height 280 mm. Suction connection R 1 1/4", exhaust connection R 1 1/4"; oil filling 2 l (Becker Lube M 100, S 100 or SL 100). A non-return valve and a PT100 temperature sensor are built in.

Order numbers

Becker assigned a separate order number to each combination of version and motor (pump with motor):
Order number Version Motor number Motor according to data sheet
G017004 SA/K (3 mbar) 42278422300003TA 2.4 / 3.0 kW; 50 Hz Δ230/Y400 IE2; 60 Hz Δ265/Y460 IE2 or Δ230/Y400; 1440 / 1735 min⁻¹
G017023 F/K (0.5 mbar) 42278422300003TA 2.4 / 3.0 kW; 50 Hz Δ230/Y400 IE2; 60 Hz Δ265/Y460 IE2 or Δ230/Y400; 1440 / 1735 min⁻¹
G017184 SA/K (3 mbar) 42378407300114TA 60 Hz only: 3.0 kW YY230/Y460 IE2 + UL/CSA, usable at 208 V; 1735 min⁻¹
G017240 F/K (0.5 mbar) 42378407300114TA 60 Hz only: 3.0 kW YY230/Y460 IE2 + UL/CSA, usable at 208 V; 1735 min⁻¹
G017185 SA/K (3 mbar) 42278453300003RE 2.4 / 3.0 kW; 50 Hz Δ200/Y350; 60 Hz Δ220/Y380-400 IE2 or Δ200/Y350; 1450 / 1740 min⁻¹
G017241 F/K (0.5 mbar) 42278453300003RE 2.4 / 3.0 kW; 50 Hz Δ200/Y350; 60 Hz Δ220/Y380-400 IE2 or Δ200/Y350; 1450 / 1740 min⁻¹
G017183 SA/K (3 mbar) 42378454300003RE 60 Hz only: 3.0 kW Δ400/Y690 IE2; 1740 min⁻¹
G017239 F/K (0.5 mbar) 42378454300003RE 60 Hz only: 3.0 kW Δ400/Y690 IE2; 1740 min⁻¹

Versions

Becker listed the versions U 4.70 GB with gas ballast valve, U 4.70-25 with oil-water cooler, U 4.70-51 with oil bath heater, level sensor and thermostat, and U 4.70 (F 35) with inlet filter F 35. For pumps in service, Ehrler & Beck supports you with service and with the selection of a current model.