The Elmo Rietschle radial blower F-RER / F-REL 620 50 for vacuum operation (type designation RER/REL 620 50) reaches a volume flow of up to 3420 m³/h at 50 Hz and a maximum static pressure difference of 71.9 mbar. The model is no longer part of the current Elmo Rietschle range. For blowers in service, Ehrler & Beck supports you with service and with the selection of a current model.
Request a quote for this product Read more
- Pumping speed 3,420 m³/h 50 Hz 2,400 m³/h 60 Hz
- Ultimate pressure 928.1 mbar
- Rated motor power 11 kW 50 Hz 13 kW 60 Hz
F-RER / F-REL 620 50 – outdated model
The radial blower F-RER / F-REL 620 50 is no longer part of the current Elmo Rietschle range; the manufacturer names no successor in its current documents. RER denotes the clockwise-rotating version, REL the counter-clockwise-rotating version; the blowers were ordered by the type designation RER/REL 620 50, and the manufacturer did not publish order numbers for them. At 50 Hz, the single-stage radial blower for vacuum operation reaches a volume flow of up to 57.0 m³/min (3420 m³/h) and a maximum static pressure difference of 71.9 mbar, at 60 Hz up to 40.0 m³/min (2400 m³/h) and a maximum of 95.5 mbar. At an ambient pressure of 1 bar this corresponds to an ultimate pressure of 928.1 mbar absolute at 50 Hz. The speed is 2850 min⁻¹ at 50 Hz and 3450 min⁻¹ at 60 Hz. Radial blowers must only be operated throttled so that the motor is not overloaded. Volume flows and pressure differences are taken from the Rietschle data sheet D 750–753 (edition 1999); motors, weights and sound pressure levels from the Elmo Rietschle F-Series catalogue (2009).| Pumping speed 50Hz | 3,420 |
|---|---|
| Pumping speed 60Hz | 2,400 |
| Ultimate pressure | 928.1 |
| Rated motor power 50Hz | 11 |
| Rated motor power 60Hz | 13 |
| Weight | 115 |
| Noise level | 87 dB(A) |
| Cooling method | Air cooling |
| Oil type | Oil-free |
Additional technical data
| Technical data | Value |
|---|---|
| Static pressure difference, max., 50 Hz / 60 Hz | 71.9 / 95.5 mbar |
| Ultimate pressure (absolute) at 1 bar ambient pressure, 50 Hz / 60 Hz | 928.1 / 904.5 mbar |
| Version 3~, 11.0 kW, 50 Hz | Volume flow 57.0 m³/min (3420 m³/h), 400/690 V, 115 kg |
| Version 3~, 13.0 kW, 60 Hz | Volume flow 40.0 m³/min (2400 m³/h), 380/660 V, 115 kg |
| Speed 50 Hz / 60 Hz | 2850 / 3450 min⁻¹ |
| Average sound pressure level, 50 Hz / 60 Hz | 87 / 89 dB(A) |
| Direction of rotation | RER clockwise, REL counter-clockwise |
| Data source | Rietschle data sheet D 750–753 (edition 1999) and Elmo Rietschle F-Series catalogue (2009) |