LRP 900 VSD+Pumping speed 940 m³/hUltimate pressure 25 mbarEdwards ELR950i Standard, plate heat exchanger
Outdated product This model is no longer part of the manufacturer's current range.
Current alternative: LRP 900 VSD+
The Edwards ELR950i is a single-stage, variable-speed liquid ring vacuum pump with a nominal pumping speed of 940 m³/h (dry) and an ultimate pressure of 25 mbar. The model is no longer part of the current Edwards range. The two order numbers are listed here for reference. For pumps in service, Ehrler & Beck supports you with service and with the selection of a current model.
Request a quote for this product Read more
- Pumping speed 940 m³/h 50 Hz 940 m³/h 60 Hz
- Ultimate pressure 25 mbar
- Rated motor power 26 kW 50 Hz 26 kW 60 Hz
| Variant | Part number |
|---|---|
| Standard, plate heat exchanger (selected) | A75167101 |
| Heavy Duty, stainless steel version, tube-and-shell heat exchanger | A75167111 |
Edwards ELR950i – outdated model
The ELR950i is no longer part of the current Edwards range; Edwards names no successor in its current documents. In the Ehrler & Beck range, the Atlas Copco LRP 900 VSD+ has the same nominal pumping speed, the same ultimate pressure and the same rated motor power as the ELR950i. The ELRi is a single-stage liquid ring vacuum pump with total recovery of the service liquid, supplied as a ready-to-connect unit under a canopy with IP 54 protection. Two variable speed drives control the main motor and the circulation pump, and the controller maintains the vacuum set point. According to the brochure, the ELR950i reaches a nominal pumping speed of 940 m³/h (dry) and 1090 m³/h (saturated) at an ultimate pressure of 25 mbar absolute; the nominal installed motor power is 26 kW. The unit measures 1950 × 810 × 1020 mm (W × D × H) and has a dry weight of 885 kg. The technical data are taken from the Edwards brochure “ELRi Series – Intelligent Liquid Ring Vacuum Pumps” (publication 3602 700 0 01, 2020).Order numbers of the ELR950i
Edwards listed the ELR950i in two versions: A75167101 (Standard, with plate heat exchanger) and A75167111 (Heavy Duty in stainless steel, with tube-and-shell heat exchanger for corrosive and dirty applications).| Pumping speed 50Hz | 940 |
|---|---|
| Pumping speed 60Hz | 940 |
| Ultimate pressure | 25 |
| Rated motor power 50Hz | 26 |
| Rated motor power 60Hz | 26 |
| Weight | 885 |
| Length | 195 |
| Width | 81 |
| Height | 102 |
| Inlet connection flange | DN 100 PN 10 |
| Outlet connection flange | DN 100 PN 10 |
| Cooling method | Water cooling |
| Oil type | Oil-free |
Additional technical data
| Technical data | Value |
|---|---|
| Nominal pumping speed, dry | 940 m³/h |
| Nominal pumping speed, saturated | 1090 m³/h |
| Ultimate pressure (absolute) | 25 mbar |
| Nominal installed motor power | 26 kW |
| Drive | variable speed, variable speed drives for main motor and circulation pump |
| Design | single-stage, total recovery of the service liquid |
| Dimensions W × D × H | 1950 × 810 × 1020 mm |
| Inlet / outlet | DN 100 PN 10 to EN 1092-1 |
| Liquid fill / manual drain | G 1/2" female thread |
| Overflow | G 1/2" female thread |
| Cooling water inlet / outlet | G 1" (ISO 228-1) |
| Dry weight | 885 kg |
| Canopy | IP 54 protection |