DRYVAC DV 200Pumping speed 210 m³/hUltimate pressure 0.05 mbarDRYVAC DV 800 3Ph 380-460 V 50/60 Hz, LEYBONOL LVO 210, double purge gas module, gas ballast valve 24 V
The Leybold DRYVAC DV 800 is a dry-compressing, water-cooled screw vacuum pump with 800 m³/h maximum pumping speed and < 5 × 10⁻³ mbar ultimate pressure in the housing of the DV 650. Ehrler & Beck supplies the DRYVAC DV 800 in eleven variants with matching accessories and service.
Request a quote for this product Read more
- Pumping speed 800 m³/h 50 Hz 800 m³/h 60 Hz
- Ultimate pressure 5 × 10-3 mbar
- Rated motor power 19.6 kW 50 Hz 19.6 kW 60 Hz
Leybold DRYVAC DV 800 – 800 m³/h on the same footprint as the DV 650
The DRYVAC DV 800 uses the housing of the DV 650 (1280 × 570 × 420 mm, around 590 kg) and increases the maximum pumping speed to 800 m³/h. The ultimate pressure is < 5 × 10⁻³ mbar, the rated power 19.6 kW and the power consumption at ultimate pressure 7 kW. The cooling water requirement is 10 l/min, the noise level with silencer 70 dB(A). Water vapour tolerance 60 mbar, water vapour capacity 30 kg/h. Like the DV 650, it has three inlet connections (DN 100 ISO-K) and the DN 63 ISO-K exhaust flange; RUVAC adapters, non-return valves and silencers are identical for both sizes.Energy Saver for processes in the medium vacuum
For the DV 650 and DV 800 with LVO 210 filling, Leybold offers the Energy Saver. It automatically lowers the exhaust pressure to 300 mbar as soon as the inlet pressure is below 5 mbar – according to the manufacturer, this reduces power consumption by up to 50 % and improves the ultimate pressure by one decade. Retrofitting is possible at any time.Typical applications
Heat treatment and metallurgy, coating, drying, chamber evacuation and load locks, backing pump in DRYVAC-RUVAC systems.Variants of the DRYVAC DV 800
The DRYVAC DV 800 is available from Ehrler & Beck in eleven variants (part numbers 112080V15-1, 112080V16-1, 112080V17-1, 112080V14-1, 112080V75-1, 112080V12-1, 112080V05-1, 112080V07-1, 1212080V17-1, 1212080V12-1, 14640800V92DGN). The rated power is 19.6 kW at 380–460 V (50/60 Hz) for all variants, the weight from 550 to 590 kg.Features of the DRYVAC series
- Oil-free pumping chamber: dry screw technology without oil backstreaming into the process
- For the harshest applications: hermetically sealed, several purge gas options, flushable
- Plug & Play: integrated frequency converter with sensors for exhaust pressure, motor and cooling water temperature, RS485 and fieldbus options
- Energy-efficient: patented rotor design and blow-off valves reduce power consumption
- Compact and water-cooled: according to Leybold significantly smaller than comparable pumps, cooling channels designed to prevent clogging
- Combinable: with RUVAC Roots pumps to form pump systems
| Pumping speed 50Hz | 800 |
|---|---|
| Pumping speed 60Hz | 800 |
| Ultimate pressure | 5 × 10-3 |
| Rated motor power 50Hz | 19.6 |
| Rated motor power 60Hz | 19.6 |
| Weight | 590 |
| Length | 128 |
| Width | 57 |
| Height | 42 |
| Inlet connection flange | DN 100 ISO-K |
| Outlet connection flange | DN 63 ISO-K |
| Noise level | 70 dB(A) |
| Cooling method | Water cooling |
| Oil type | LEYBONOL LVO 210 |
Additional technical data
| Technical data | Value |
|---|---|
| Max. pumping speed (without gas ballast) | 800 m³/h |
| Ultimate pressure without gas ballast | < 5 × 10⁻³ mbar |
| Ultimate pressure with gas ballast | 0.1 mbar |
| Ultimate pressure with rotor purge gas | 1 × 10⁻² mbar |
| Water vapour tolerance | 60 mbar (with purge gas and gas ballast) |
| Water vapour capacity | 30 kg/h |
| Max. permissible inlet pressure | 1050 mbar |
| Max. permissible exhaust pressure | 1200 mbar |
| Integral leak rate | < 10⁻⁴ mbar·l/s |
| Rated power | 19.6 kW |
| Power consumption at ultimate pressure | 7 kW |
| Rated current at 400 V | 38 A |
| Mains voltage | 380-460 V ± 10 %, 50/60 Hz, 3-phase |
| Frequency converter | on the pump |
| Lubricant | LEYBONOL LVO 210 (synthetic oil), filling quantity 1.2 l |
| Equipment | Double purge gas module, gas ballast valve 24 V |
| Inlet connection | DN 100 ISO-K (1 × top, 2 × side) |
| Exhaust connection | DN 63 ISO-K |
| Cooling | Water |
| Cooling water flow, nominal | 10 l/min |
| Cooling water temperature | 5 to 35 °C |
| Cooling water connection | G 1/2" female thread with cooling water unit, G 1/4" without the unit |
| Purge gas connection | Quick connect D10 |
| Noise level | 70 dB(A) with silencer, at ultimate pressure (DIN EN ISO 2151) |
| IP protection class | IP 54 |
| Permissible ambient temperature | 5 to 50 °C (operating instructions: +5 to +45 °C) |
| Relative humidity | 90 %, non-condensing |
| Installation altitude, max. | 2000 m above sea level |
| Materials in the pumping chamber | Grey cast iron, spheroidal graphite cast iron, FKM, steel, stainless steel, epoxy paint |
| Product name | Part number |
|---|---|
| Plug screw M 16 x 1.5 (oil filler plug) | ES20127105 |
| Gasket for plug screw (oil filler plug) | ES23955165 |
| Filter cartridge for purge gas pressure reducer | E110000850 |
| Air filter for gas ballast valve | E110000980 |
| Pressure reducing cartridge for cooling water unit | E6519936 |
| LEYBONOL LVO 210, 5 litres | L21005 |
| LEYBONOL LVO 210, 208 litres | L21099 |
| Product name | Part number |
|---|---|
| Roots adapter RUVAC WH 700 for DV 650/800 | 112005A03 |
| Roots adapter RUVAC WS(U) 1001 for DV 650/800 | 112005A04 |
| Roots adapter RUVAC WS(U) 2001 for DV 650/800 | 112005A05 |
| Roots adapter RUVAC WH(U) 2500 for DV 650/800 | 112005A07 |
| Roots adapter RUVAC WH(U) 4400/7000 for DV 650/800 | 112005A10 |
| Non-return valve DRYVAC DV 450/650/800 (disc, spring-loaded) | 112005A14 |
| Non-return valve DRYVAC DN 63 ISO-K (flap) | 112005A15 |
| Silencer DN 63 ISO-K | 119002 |
| Serviceable silencer DN 63 ISO-K | 119003V |
| Stainless steel silencer DRYVAC 650/800 | 112005A50 |
| DRYVAC Energy Saver (only with LVO 210) | 112005A60 |
| Cooling water unit DRYVAC 450/650/800 S | 112005A12 |
| Cooling water unit DRYVAC 450/650/800 S-r | 112005A13 |
| Gas ballast kit DRYVAC 24 V, electro-pneumatic | 112005A17 |
| Set of nozzles for DRYVAC purge gas (not for new purge gas modules) | 112005A30 |
| Permanent inlet purge kit DRYVAC (not for new purge gas modules) | 112005A32 |
| Inlet adapter G 3" female thread | 112005A18 |
| Inlet adapter G 4" female thread | 112005A19 |
| Outlet flange DN 63 ISO-K × 80 mm | 112005A62 |
| External display (LCD operator panel) | 112005A80 |
| Frequency converter IP 66 for DV 650-r | 112005A65 |
| 200 V filter for IT network | 112005A26 |
| PROFIBUS DP module | 112005A78 |
| PROFINET module | 112005A75 |
| EtherCAT module | 112005A76 |
| Relay module (digital output) | 112005A70 |
| Ethernet module (dual port) | 112005A72 |
| GENIUS retrofit kit (Genius Box) | 175001A01 |