G-BH1 2BH1 530 blower

The blower G-BH1 530 is reliable, durable and low-maintenance. G-BH1 blowers have a high intake volume flow of up to 2,500 m³/h and a differential pressure of up to 780 mbar. Side channel blowers G-BH1 from Elmo Rietschle have earned their reputation. G-BH1 series blowers can provide up to 20,000 hours of trouble-free operation.

Manufacturer: Elmo Rietschle

Series: G series

G-BH1 2BH1 530 blowers with IE1 motors

frequency rated Max differential pressure sound pressure level weight approx. Order no.
Tension Electricity Performance vacuum compressor
Hz V A kW mbar dB(A) kg  
3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CNA/CSA 22.2 No 68-09 (certificate number E225239)  
50 200 – 240 ∆ / 345 – 415 Y 5.7∆/3.3Y 1,3 -120 110 65 23 2BH1530-7AH16
60 220 – 275 ∆ / 380 – 480 Y 5.7∆/3.3Y 1,5 -90 80 71
50 200 – 240 ∆ / 345 – 415 Y 7.5∆/4.3Y 1,6 -160 150 65 24 2BH1530-7AH26
60 220 – 275 ∆ / 380 – 480 Y 7.6∆/4.4Y 2,05 -160 150 71
50 200 – 240 ∆ / 345 – 415 Y 9.7∆/5.6Y 2,2 -220 230 65 26 2BH1530-7AH36
60 220 – 275 ∆ / 380 – 480 Y 10.3∆/6Y 2,55 -260 250 71
3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CNA/CSA 22.2 No 68-09 (certificate number E225239)  
50 500∆ 2.65Y 1,3 -120 110 65 23 2BH1530-7AC13
60 575 ∆ 2.60Y 1,5 -90 80 71
50 500∆ 2.9Y 1,5 -160 150 65 24 2BH1530-7AC23
60 575 ∆ 2.95Y 1,75 -160 150 71
50 500∆ 4.5Y 2,2 -220 230 65 26 2BH1530-7AC33
60 575 ∆ 4.55Y 2,55 -260 250 71
1~ 50/60 Hz, IP55, insulation class F, UL 1450 and CNA/CSA 22.2 No 68-09 (certificate number E225239), with continuous duty condenser fitted.  
50 115 / 230 22,0 / 11,0 1,5 -160 150 65 26 2BH1530-7AV35
60 115 / 230 24,0 / 12,0 1,75 -140 130 71
50 115 / 230 28,0 / 14,0 2,2 -200 230 65 26 2BH1530-7AV65
60 115 / 230 28,0 / 14,0 2,55 -220 200 71

Aother technical data on request

G-BH1 2BH1 530 blowers with IE2 motors

frequency rated Max differential pressure sound pressure level weight approx. Order no.
Tension Electricity Performance vacuum compressor
Hz V A kW mbar dB(A) kg  
3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CNA/CSA 22.2 No 68-09 (certificate number E225239)  
50 230∆ / 400Y 3.9∆/2.25Y 1,1 -80 80 65 23 2BH1530-7AP16
60 265∆ / 460Y 3.8∆/2.15Y 1,27 -60 50 71
50 230∆ / 400Y 5.3∆/3.05Y 1,5 -140 130 65 24 2BH1530-7AP26
60 265∆ / 460Y 5.1∆/2.95Y 1,75 -110 100 71
50 230∆ / 400Y 7.6∆/4.4Y 2,2 -220 230 65 26 2BH1530-7AP36
60 265∆ / 460Y 7.6∆/4.4Y 2,55 -220 200 71
3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CNA/CSA 22.2 No 68-09 (certificate number E225239)  
50 500Y 1.79Y 1,1 -80 80 65 23 2BH1530-7AP13
60 575 Y 1.76Y 1,27 -60 50 71
50 500Y 2.45Y 1,5 -140 130 65 24 2BH1530-7AP23
60 575 Y 2.4Y 1,75 -110 100 71
50 500Y 3.5Y 2,2 -220 230 65 26 2BH1530-7AP33
60 575 Y 3.5Y 2,55 -220 200 71

Aother technical data on request

G-BH1 2BH1 530 blowers with IE3 motors

frequency rated Max differential pressure sound pressure level weight approx. Order no.
Tension Electricity Performance vacuum compressor
Hz V A kW mbar dB(A) kg  
3~ 50/60 Hz, IP55, insulation class F, UL 1004 and CNA/CSA 22.2 No 68-09 (certificate number E225239)  
50 190-210∆ 4.7∆ 1,30 -120 110 65 30 2BH1530-1AK11
60 190-210YY / 380-420Y 6.3YY / 3.16Y 1,60 -90 80 71
60 230∆ 6.3∆ 1,60 -90 80 71
50 190-210∆ 6.1∆ 1,75 -180 170 65 33 2BH1530-1AK21
60 190-210YY / 380-420Y 7.8YY / 3.9Y 2,00 -160 140 71
60 200YY 7.8YY 2,00 -160 140 71
50 190-210∆ 8.7∆ 2,50 -220 260 65 36 2BH1530-1AK31
60 190-210YY / 380-420Y 12.0YY / 6.0Y 3,00 -260 250 71
60 230∆ 12.0YY 3,00 -260 250 71
3~ 50/60 Hz, IP55, insulation class F, UL 1004 and CNA/CSA 22.2 No 68-09 (certificate number E225239)
50 220-240 ∆ / 380-420 Y 4.5∆/2.85Y 1,30 -120 110 65 30 2BH1530-1AK16
60 220-240YY / 440-480Y 5.5YY / 2.75Y 1,60 -90 80 71
50 230YY / 460Y 5.5YY / 2.75Y 1,60 -90 80 71
60 220-240 ∆ / 380-420 Y 6.0∆/3.45Y 1,75 -180 170 65 33 2BH1530-1AK26
50 220-240YY / 440-480Y 6.8YY / 3.4Y 2,00 -160 140 71
60 230YY / 460Y 6.8YY / 3.4Y 2,00 -160 140 71
50 220-240 ∆ / 380-420 Y 7.5∆/5.0Y 2,50 -220 260 65 36 2BH1530-1AK36
60 220-240YY / 440-480Y 10.4YY / 5.2Y 3,00 -260 250 71
50 230YY / 460Y 10.4YY / 5.2Y 3,00 -260 250 71
3~ 50/60 Hz, IP55, insulation class F, UL 1004 and CNA/CSA 22.2 No 68-09 (certificate number E225239)  
50 500∆ 2.28y 1,30 -90 80 64 29 2BH1530-1AQ13
60 575 ∆ 2.20Y 1,60 -90 80 70
50 500∆ 2.76Y 1,75 -180 170 64 32 2BH1530-1AQ23
60 575 ∆ 2.72Y 2,00 -160 140 70
50 500∆ 4.00Y 2,50 -220 260 64 40 2BH1530-1AQ33
60 575 ∆ 4.10Y 3,00 -260 250 70
3~ 50/60 Hz, IP55, insulation class F, UL 1004 and CNA/CSA 22.2 No 68-09 (certificate number E225239)
50 380-420 ∆ / 660-725 Y 2.85∆/1.10Y 1,30 -120 110 65 30 2BH1530-1AQ17
60 440-480∆ 2.75∆ 1,60 -120 110 71
50 460∆ 2.75∆ 1,60 -90 80 71
60 380-420 ∆ / 660-725 Y 3.45∆ / 2.00Y 1,75 -180 170 65 33 2BH1530-1AQ27
50 440-480∆ 3.4∆ 2,00 -160 140 71
60 460∆ 3.4∆ 2,00 -160 140 71
50 380-420 ∆ / 660-725 Y 5.0∆/2.90Y 2,50 -220 260 65 36 2BH1530-1AQ37
60 440-480∆ 5.2∆ 3,00 -260 250 71
50 460∆ 5.2∆ 3,00 -260 250 71

Aother technical data on request

G-BH1 2BH1 530 fan with frequency converter

frequency rated Max differential pressure sound pressure level weight approx. Order no.
Tension Electricity Performance vacuum compressor
Hz V A kW mbar dB(A) kg  
Integrated frequency converter 3~ 400V -15% … 480V +10%, 50/60 Hz ±6% with PTC sensor, IP55, UL 1450 and CNA/CSA 22.2 No 68-09  
87 345 ∆ 8.8∆ 3,8 -150 120 76 33 2BH1530-7A231
3~ 50/60 Hz, IP55, insulation class F, UL 1450 and CNA/CSA 22.2 No 68-09 (certificate number E225239)  
50 345Y 3.6Y 1,5 -140 130 65 24 2BH1530-7AP21
60 400Y 3.4Y 1,75 -110 100 71
87 290∆ 6.1∆ 2,1 -70 60 76
50 345Y 5.1Y 2,2 -220 230 65 26 2BH1530-7AP31
60 400Y 5.1Y 2,55 -220 200 71
87 345 ∆ 8.8∆ 3,8 -150 120 76

Aother technical data on request