RUVAC series (LEYBOLD)

RUVAC WA / WAU

The RUVAC WA Roots dry-compressing vacuum pumps are pumps in which no lubricant comes into contact with the medium to be pumped and therefore the vacuum created cannot be contaminated by hydrocarbons. The seals are made of FPM.

RUVAC WS / WSU

The Roots vacuum pumps of the RUVAC WS series are driven by air- or water-cooled canned motors. An optional frequency converter is matched to the pump in such a way that mechanical overloading is ruled out. If the pressure difference is too great, the speed of the pump is automatically reduced until its load is within the permissible range. The RUVAC WSU variants are also equipped with an integrated pressure compensation line and a pressure difference valve. The pumps in this series are delivered with a vertical pumping direction as standard.

Leybold Ruvac series

RUVAC WH / WHU

The RUVAC WH / WHU series is equipped with a hermetically sealed motor without shaft seals and with integrated water cooling. It also has a purge gas option and is therefore suitable for conveying corrosive and toxic gases. The RUVAC WHU model variants also have an integrated detour line with a newly developed control flap. This means that the pumps can be started at atmospheric pressure and the pump-down times in the short cycle are significantly reduced.

Do not hesitate to contact us for more information:

e-mail: info@ehrler-beck.com

phone: +49 (0) 7159 / 4085-0

Benefits for the user

RUVAC WA/WAU

  • Two air-cooled series, WA/WAU, each with four pump sizes
  • Flexibility with custom motors for special voltages and compliance with explosion-proof requirements
  • Versions with ATEX cat. 3i/o available. All WA(U) pumps comply with the ATEX Cat. 3i standard
  • Easy maintenance and replacement of oil seals
  • Integrated pressure equalization line on WAU models to protect against overload at high pressure
  • Conversion from vertical to horizontal flow on site

RUVAC WS/WSU

  • Two air-cooled series, WS/WSU, each with four pump sizes
  • Highly leak-tight, air-cooled pumps driven by an air-cooled canned motor
  • Lubricated with mineral oil (alternatively with LVO 400)
  • Overtemperature switch in the motor stator coil
  • All elastomer seals made of FPM (FKM)/Viton
  • Integrated pressure compensation line with differential pressure valve prevents overloading on the WSU model (optional)
  • With a frequency converter, the RUVAC WS 251 to 2001 pumps can be operated at 20 to 100 Hz

RUVAC WH/WHU

  • Trouble-free operation with toxic or corrosive media thanks to the hermetically sealed motor
  • Compact design with minimal space requirement
  • No shaft sealing rings to the atmosphere, therefore high reliability, long maintenance intervals and no oil leaks
  • Easy system integration
  • Optional frequency converter for high pumping speeds of up to 9,800 m³/h at 70 Hz
  • Lower energy costs thanks to innovative motor technology
  • Integrated water cooling system for installation in air-conditioned production facilities

Found 23 results
Page 1 of 2

RUVAC WA 251 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 253 m³/h 304 m³/h
final total pressure 8x10-4 mbar
engine power 1.1kW 1.1kW


RUVAC WA 501 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 505 m³/h 606 m³/h
final total pressure 4x10-2 mbar
engine power 2.2kW 2.2kW


RUVAC WA 1001 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 1000 m³/h 1200 m³/h
final total pressure 0.04 mbar
engine power 4.0kW 4.0kW


RUVAC WA 2001 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 2050 m³/h 2460 m³/h
final total pressure 0.04 mbar
engine power 7.5kW 7.5kW


RUVAC WAU 251 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 253 m³/h 304 m³/h
final total pressure 8x10-4 mbar
engine power 1.1kW 1.1kW


RUVAC WAU 501 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 505 m³/h 606 m³/h
final total pressure 4x10-2 mbar
engine power 2.2kW 2.2kW


RUVAC WAU 1001 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 1000 m³/h 1200 m³/h
final total pressure 0.04 mbar
engine power 4.0kW 4.0kW


RUVAC WAU 2001 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 2050 m³/h 2460 m³/h
final total pressure 0.04 mbar
engine power 7.5kW 7.5kW


RUVAC WSU 251 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 253 m³/h 304 m³/h
final total pressure 8x10-4 mbar
engine power 1.1kW 1.4kW


RUVAC WSU 501 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 505 m³/h 606 m³/h
final total pressure 0.04 mbar
engine power 2.2kW 2.4kW


RUVAC WSU 1001 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 1000 m³/h 1200 m³/h
final total pressure 0.04 mbar
engine power 4.0kW 4.4kW


RUVAC WSU 2001 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 2050 m³/h 2460 m³/h
final total pressure 0.04 mbar
engine power 7.5kW 8.5kW


RUVAC WS 251 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 253 m³/h 304 m³/h
final total pressure 8x10-4 mbar
engine power 1.1kW 1.4kW


RUVAC WS 501 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 505 m³/h 606 m³/h
final total pressure 0.04 mbar
engine power 2.2kW 2.4kW


RUVAC WS 1001 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 1000 m³/h 1200 m³/h
final total pressure 0.04 mbar
engine power 4.0kW 4.4kW


RUVAC WS 2001 vacuum pump

Designation Value
frequency 50Hz 60Hz
nominal pumping speed 2050 m³/h 2460 m³/h
final total pressure 0.04 mbar
engine power 7.5kW 8.5kW


RUVAC WH 700 vacuum pump

Designation Value
frequency 50Hz 60Hz 80Hz 120Hz
nominal pumping speed 710 m³/h 860 m³/h 1150 m³/h 1730 m³/h
Max. allowed pressure difference 75 mbar 65 mbar 50 mbar 30 mbar
rated power consumption 3.5kW


RUVAC WH 2500 vacuum pump

Designation Value
frequency 50Hz 60Hz 80Hz 100Hz
nominal pumping speed 2500 m³/h 3000 m³/h 4000 m³/h 5000 m³/h
Max. allowed pressure difference 50 – 75 mbar 40 – 60 mbar 30 – 40 mbar 20 mbar
rated power consumption 11.0kW


RUVAC WH 4400 vacuum pump

Designation Value
frequency 50Hz 60Hz 80Hz
nominal pumping speed 4400 m³/h 5280 m³/h 7040 m³/h
Max. allowed pressure difference 30 – 45 mbar 20 – 30 mbar 8 – 12 mbar
rated power consumption 11.0 / 15.0 kW


RUVAC WH 7000 vacuum pump

Designation Value
frequency 50Hz 60Hz 80Hz
nominal pumping speed 7000 m³/h 8000 m³/h 9800 m³/h
Max. allowed pressure difference 20 – 30 mbar 14 – 21 mbar 11 – 14 mbar
rated power consumption 11.0 / 15.0 kW


Page 1 of 2