The impellers of FPZ blowers are made of aluminum alloy and are dynamically balanced. All standard FPZ blowers are supplied with built-in in-outlet silencers, which can then be modified to suit various deployment configurations.
MS Blower = One impeller, single stage
MD fan = One impeller, two-stage
TS blower = double impeller, single-stage
TD fan = double impeller, two-stage
In addition to the standard side channel blowers, FPZ has also developed special configurations that allow the machine to adapt to the most diverse industries that require the use of a blower.
MD blower
Single wheel - two-stage
Integral motor design versions, aluminum construction, capacity up to 473 m³ / h (50 Hz) / 570 m³ / h (60 Hz), ambient temperature from -15 to + 40 ° C
Two-pole electric motors, three-phase asynchronous, insulation class F - suitable for the tropics and protection class IP55.
Printing Applications:
Maximum flow up to 570 m³ / h Maximum pressure up to 750 mbar
Vacuum applications:
Maximum flow up to 570 m³ / h Maximum pressure up to 500 mbar
MS blower
Single wheel - single stage
Integrated motor design versions, aluminum construction, capacity up to 1022 m³ / h (50 Hz) / 1234 m³ / h (60 Hz), ambient temperature from -15 to + 40 ° C
Two-pole electric motors, single-phase and three-phase asynchronous, insulation class F-suitable for the tropics.
Printing Applications:
Maximum flow up to 1234 m³ / h, Maximum pressure up to 500 mbar
Vacuum applications:
Maximum flow up to 1234 m³ / h, Maximum pressure up to 375 mbar
TD blower
Double impeller - two-stage
Integrated motor design versions, aluminum construction, capacity up to 1007 m³ / h (50 Hz) / 1216 m³ / h (60 Hz), ambient temperature from -15 to + 40 ° C
Two-pole electric motors, single-phase and three-phase asynchronous, insulation class F - Tropicalized and IP55 protection.
Printing Applications:
Maximum flow up to 1216 m³ / h. Maximum pressure up to 650 mbar
Vacuum applications:
Maximum flow up to 1216 m³ / h. Maximum pressure up to 500 mbar
TS blower
Double impeller - single stage
Integral motor design versions, aluminum construction, capacity up to 1985 m³ / h (50 Hz) / 2395 m³ / h (60 Hz), ambient temperature from -15 to + 40 ° C
Two-pole electric motors, three-phase asynchronous, insulation class F - suitable for the tropics and protection class IP55.
Printing Applications:
Maximum flow up to 2395 m³ / h Maximum pressure up to 450 mbar
Vacuum applications:
Maximum flow up to 2395 m³ / h Maximum pressure up to 350 mbar
Page 2 of 2
K10-MD Blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 386 m³/h | 466 m³/h |
Pressure difference - vacuum / pressure | 340-500 / 340-750 mbar | 260-500 / 260-700 mbar |
engine power | 5.5 - 11.0 kW | 6.3-12.7kW |
K11-MD Blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 430 m³/h | 519 m³/h |
Pressure difference - vacuum / pressure | 250-500 / 250-750 mbar | 175-500 / 175-750 mbar |
engine power | 5.5 - 15.0 kW | 6.3-17.4kW |
K12-MD Blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 472 m³/h | 570 m³/h |
Pressure difference - vacuum / pressure | 225-450 / 225-650 mbar | 200-450 / 200-500 mbar |
engine power | 7.5 - 15.0 kW | 8,7 – 17,4 kW |
K03-MS blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 74 m³/h | 89 m³/h |
Pressure difference - vacuum / pressure | 120 / 130 mbar | 120 / 120 mbar |
engine power | 0.37kW | 0.43kW |
K04-MS blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 137 m³/h | 166 m³/h |
Pressure difference - vacuum / pressure | 140-225 / 140-250 mbar | 120-250 / 120-250 mbar |
engine power | 0,75 – 1,5 kW | 0,9 – 1,75 kW |
K05-MS blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 219 m³/h | 265 m³/h |
Pressure difference - vacuum / pressure | 130-240 / 130-300 mbar | 100-275 / 100-350 mbar |
engine power | 1.1 -3.0 kW | 1.3 – 3.45 kW |
K06-MS blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 304 m³/h | 366 m³/h |
Pressure difference - vacuum / pressure | 180-270/ 180-340 mbar | 150-325 / 150-220 mbar |
engine power | 2.2-4.0kW | 2,55-4,6 kW |
K07-MS blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 414 m³/h | 499 m³/h |
Pressure difference - vacuum / pressure | 130-325 / 130-400 mbar | 100-375 / 100-375 mbar |
engine power | 2.2-5.5 kW | 2,55-6,3 kW |
K08-MS blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 536 m³/h | 647 m³/h |
Pressure difference - vacuum / pressure | 125-350 / 125-450 mbar | 100-375 / 100-450 mbar |
engine power | 3,0 – 9,2 kW | 3,45 – 10,6 kW |
K09-MS Blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 663 m³/h | 800 m³/h |
Pressure difference - vacuum / pressure | 130-350 / 130-450 mbar | 85-375 / 85-400 mbar |
engine power | 4 – 11 kW | 4,6 – 12,7 kW |
K10-MS Blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 782 m³/h | 944 m³/h |
Pressure difference - vacuum / pressure | 160-350 / 160-500 mbar | 115-375 / 115-500 mbar |
engine power | 5.5 - 15.0 kW | 6.3-17.4kW |
K11-MS Blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 915 m³/h | 1105 m³/h |
Pressure difference - vacuum / pressure | 175-350 / 175-500 mbar | 130-350 / 130-500 mbar |
engine power | 7,5 – 18,5 kW | 8,7 – 21,5 kW |
K12-MS Blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 1022 m³/h | 1234 m³/h |
Pressure difference - vacuum / pressure | 150-325 / 150-425 mbar | 100-350 / 100-375 mbar |
engine power | 9.2-18.5kW | 10.6-21.5kW |
K75-MS Blower
Designation | Value | |
frequency | 50Hz | 60Hz |
flow rate | 477 m³/h | 576 m³/h |
Pressure difference - vacuum / pressure | 150-250 / 150-325 mbar | 100-300 / 100-300 mbar |
engine power | 4.0-7.5kW | 4.6-8.7kW |
Page 2 of 2