Panda and Puma vacuum boosters are dry vacuum generators that can be used in combination with a backing pump in all rough and medium vacuum processes. As a booster in such a vacuum system, they increase the performance data of the backing pump enormously.
PANDA / PUMA SERIES ADVANTAGES
- Oil-free operation
- Wide range of sizes available
- Higher pumping speed
- Economically
- Safe Operations
SAFE OPERATION
Panda vacuum boosters are also equipped with an integrated bypass valve. This means that they can be used with all pressure differences.
ECONOMICALLY
Due to the large number of available sizes and versions, the pumping speeds and ultimate pressures of vacuum systems can be precisely matched to the process conditions using Panda or Puma vacuum boosters. Due to the high volumetric efficiency and the oil and non-contact functional principle, extremely economical operation is possible.
Page 2 of 2
PUMA WP 1000 D2 vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 1035 m³/h | 1240 m³/h |
Max. pressure difference | 50 mbar | |
motor rated power | 3.5kW | 4.8kW |
PUMA WP 1000 D4 vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 1010 m³/h | 1220 m³/h |
Max. pressure difference | 80 mbar | |
motor rated power | 3.0kW | 4.2kW |
PUMA WP 1250 D2 vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 1295 m³/h | 1555 m³/h |
Max. pressure difference | 50 mbar | |
motor rated power | 4.2kW | 5.2kW |
PUMA WP 2000 D2 vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 2020 m³/h | 2435 m³/h |
Max. pressure difference | 50 mbar | |
motor rated power | 6.0kW | 7.6kW |
PUMA WP 4500 B2 vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 4500 m³/h | 5400 m³/h |
Max. pressure difference | 30 mbar | |
motor rated power | 11.0kW | 12.6kW |
PUMA WP A040 A vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 3850 m³/h | 4700 m³/h |
Max. pressure difference | 75 – 100 mbar | |
motor rated power | 11,0 – 15,0 kW | 12,5 – 17,0 kW |
PUMA WP A055 A vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 5500 m³/h | 6650 m³/h |
Max. pressure difference | 80 – 100 mbar | |
motor rated power | 15,0 – 18,5 kW | 17,0 – 21,0 kW |
PUMA WP A075 A vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 7350 m³/h | 8950 m³/h |
Max. pressure difference | 100 mbar | |
motor rated power | 18.5kW | 21,0 kW |
PUMA WP A080 A vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 8000 m³/h | 9800 m³/h |
Max. pressure difference | 75 – 95 mbar | |
motor rated power | 18.5 - 22.0 kW | 21,0 – 25,0 kW |
PUMA WP A095 A vacuum pump
Designation | Value | |
frequency | 50Hz | 60Hz |
nominal pumping speed | 9535 m³/h | 11600 m³/h |
Max. pressure difference | 75 mbar | |
motor rated power | 22.0kW | 25.0kW |
Page 2 of 2