SOGEVAC SV 100 B vacuum pump
- Best effective pumping speed in this class
- Good pump temperature thanks to cooling coil: ideal for tough applications and long oil life
- World engine as standard
- Optimal integrated lubrication without external oil lines
- Integrated oil recovery system and vacuum safety valve
- Quiet
Manufacturer: LEYBOLD
Series: SOGEVAC B series
Technology: Rotary vane vacuum pumps Oil lubricated
TECHNICAL SPECIFICATIONS
frequency | Hz | 50 | 50 |
nominal pumping speed | m³/h | 97,5 | 117 |
pumping speed | m³/h | 87,5 | 105 |
Final total pressure without gas ballast | mbar | ≤ 0.5 | ≤ 0.5 |
Final total pressure with standard gas ballast | ≤ 1.5 | ≤ 1.5 | |
Final total pressure with small gas ballast | ≤ 0.8 | ≤ 0.8 | |
Water vapor tolerance with standard gas ballast | 30 | 30 | |
Water vapor tolerance with small gas ballast | 10 | 10 | |
Max. allowable water vapor capacity with standard gas ballast | kg/hr | 1,6 | 1,7 |
Max. allowable water vapor capacity with small gas ballast | 0,45 | 0,6 | |
oil filling | l | 2,0 | 2,0 |
Average sound pressure level | dB(A) | 61 | 64 |
Permissible ambient temperature | °C | +12 to +40 | +12 to +40 |
engine power | kW | 2,2 | 3,5 |
rated speed | at least-1 | 1500 | 1800 |
Degree of protection | IP | 55 | 55 |
insulation class | f | ||
Materials (components in contact with gas) | steel, cast iron, aluminium, bronze, FPM, glass, GRP, polyamide 6.6, Filter media (polymers, paper) |
||
Weight (with oil filling) | kg | 92 | 93 |
Connections (internal thread) suction side | G or NPT | 1 1/4″ | 1 1/4″ |
Connections (internal thread) exhaust side | G or NPT | 1 1/4″ | 1 1/4″ |
Product description | Order no. |
with three-phase motor, without gas ballast, without oil filter 230/400V, 50Hz and 460V, 60Hz (CEI) |
960 500 |
with three-phase motor, without gas ballast, with oil filter 230/400V, 50Hz and 460V, 60Hz (CEI) |
960 502 |
with three-phase motor, with small gas ballast, without oil filter | |
230/400V, 50Hz and 460V, 60Hz (CEI) | 960 501 |
230/460V, 60Hz and 400V, 50Hz (NEMA) | 960 511 |
230/400V, 50/60Hz and 460V, 60Hz (CEI) | 960 521 |
200V, 50/60Hz (JIS) | 960 516 |
with three-phase motor, with small gas ballast, with oil filter | |
230/400V, 50Hz and 460V, 60Hz (CEI) | 960 503 |
230/460V, 60Hz and 400V, 50Hz (NEMA) | 960 513 |
230/400V, 50/60Hz and 460V, 60Hz (CEI) | 960 523 |
200V, 50/60Hz (JIS) | 960 518 |
with three-phase motor, with standard gas ballast, without oil filter | |
230/400V, 50Hz and 460V, 60Hz (CEI) | 960 505 |
230/460V, 60Hz and 400V, 50Hz (NEMA) | 960 512 |
230/400V, 50/60Hz and 460V, 60Hz (CEI) | 960 522 |
200V, 50/60Hz (JIS) | 960 517 |
with three-phase motor, with standard gas ballast, with oil filter | |
230/400V, 50Hz and 460V, 60Hz (CEI) | 960 507 |
230/460V, 60Hz and 400V, 50Hz (NEMA) | 960 514 |
230/400V, 50/60Hz and 460V, 60Hz (CEI) | 960 524 |
200V, 50/60Hz (JIS) | 960 519 |
QUOTE REQUEST