DVT 3.80 pressure vacuum pumps

The robust rotary vane pump DVT 3.80 is suitable for higher pressure differences in vacuum and/or pressure applications. An eccentrically mounted rotor with slits in which precisely fitting slides move and separate the individual working chambers rotates in a cylindrical housing.

Manufacturer: BECKER

DVT 3.80 Druck-Vakuumpumpen Technische Daten

frequency Hz 50 60
flow rate m³/h 70 82
Motor power (3~) kW 4,0 4,8
Motor power (1~) kW 4,0 4,8
vacuum / overpressure bar ±0.5
±0.6
Average sound pressure level dB(A) 75-76 76-77
Max Weight (3~/1~) kg 113,5

 

relative pressure(bar) 50 Hz - relative vacuum (bar)
60 Hz - relative vacuum (bar)
0 -0,4 -0,5 -0,6 0 -0,4 -0,5 -0,6
amount of suction air m³/h 0.4 bars 64 32,5 25 18 77,7 40,7 31,9 23,8
blown air volume m³/h 66 51,9 47,5 43,1 82,7 63 56,8 50,9
power consumption kW 2,12 2,58 2,65 2,72 2,92 3,33 3,36 3,38
blast air temperature °C 41 45 46 47 44 48 49 49
amount of suction air m³/h 0.5 bars 63,9 32,2 25 18,1 76,5 40,6 31,9 23,4
blown air volume m³/h 65 51,4 47,1 43 81,4 62,9 56,8 50,6
power consumption kW 2,18 2,65 2,74 2,8 2,93 3,38 3,44 3,46
blast air temperature °C 41 47 47 48 44 49 51 50
amount of suction air m³/h 0.6 bars 63 32 24,7 17,5 76 40,6 31,6 23,5
blown air volume m³/h 64,8 51,1 46,8 42,3 80,6 62,5 56 50,2
power consumption kW 2,26 2,75 2,82 2,91 3,01 3,48 3,52 3,57
blast air temperature °C 43 46 48 48 46 51 51 51

Variante:

DVT 3.80/0-43
DVT 3.80/0-56
DVT 3.80/0-68
DVT 3.80/0-74

Other technical data on request

Wartungsteile für DVT 3.80 Druck-Vakuumpumpe

Crowd Order no. Designation
SENTENCE 549000 21100 gasket kit
SENTENCE 549002 21100 gasket kit
SENTENCE 901330 00007 slider
1 909507 00000 filter cartridge
1 909506 00000 filter cartridge
1 909510 00000 filter cartridge

Further spare parts and accessories on request