V-KTA 80 pressure vacuum pumps

V-KTA offers the flexibility to change vacuum and compressed air capacities for individual applications: Version / 1 standard vacuum and pressure capacity; Version / 2 – maximum compressed air capacity; Version / 3 – maximum vacuum capacity. High efficiency and quiet operation.

V-KTA 80 pressure-vacuum pumps IE2 motors Technical data

frequency Hz 50 60
rated voltage 3~ 230 / 400V ± 10 % 265/460V±10 %
engine power kW 3.0 - 4.0 3.6 - 4.8
power consumption A 10,6/6,1 | 14,0/8,1 18,5/10,7 | 21,0/12,0
number of revolutions at least-1 1450 1740
Average sound pressure level dB(A) 75 77
Max weight kg 96-123

Other technical data on request

V-KTA 80/1 pressure-vacuum pumps IE2 motors Technical data

vacuum suction air bar 0 -0,4 -0,5 -0,6 0 -0,4 -0,5 -0,6
overpressure compressed air bar +0,6 +0,7
suction air volume flow m³/h (50 Hz) 66,0 56,3 52,7 48,2 65,0 55,4 51,7 47,0
m³/h (60 Hz) 77,9 66,4 62,2 56,9 76,7 65,4 61,0 55,5
Compressed air volume flow m³/h (50 Hz) 62,8 50,8 47,5 43,8 62,0 50,0 46,6 43,0
m³/h (60 Hz) 74,1 59,9 56,0 51,7 73,2 59,0 55,0 50,7
engine power kW (50Hz) 3,0 4,0
kW (60Hz) 4,8

Other technical data on request

V-KTA 80/2 pressure-vacuum pumps IE2 motors Technical data

vacuum suction air bar 0 -0,4 -0,5 -0,6 0 -0,4 -0,5 -0,6
overpressure compressed air bar +0,6 +0,7
suction air volume flow m³/h (50 Hz) 47,2 37,8 34,5 30,0 46,3 37,0 33,5 29,0
m³/h (60 Hz) 55,7 44,6 40,7 35,4 54,6 43,7 39,5 34,2
Compressed air volume flow m³/h (50 Hz) 67,2 56,4 53,7 51,0 66,5 55,4 52,6 50,0
m³/h (60 Hz) 79,3 66,6 63,4 60,2 78,5 65,4 62,1 59,0
engine power kW (50Hz) 4,0
kW (60Hz) 4,8

Other technical data on request

V-KTA 80/3 pressure-vacuum pumps IE2 motors Technical data

vacuum suction air bar 0 0 -0,4 -0,5 -0,6 0 -0,4 -0,5 -0,6
overpressure compressed air bar 0 +0,4 +0,5
suction air volume flow m³/h (50 Hz) 59,5 57,2 48,6 45,9 43,0 56,6 47,8 45,1 42,2
m³/h (60 Hz) 70,2 67,5 57,3 54,2 50,7 66,8 56,4 53,2 49,8
Compressed air volume flow m³/h (50 Hz) 45,0 42,5 32,6 29,7 26,4 41,6 31,8 28,9 25,6
m³/h (60 Hz) 53,1 50,2 38,5 35,0 31,2 49,1 37,5 34,1 30,2
engine power kW (50Hz) 3,0 4,0 3,0 4,0
kW (60Hz) 4,8

Other technical data on request

V-KTA 80 pressure-vacuum pumps IE3 motors Technical data

frequency Hz 50 60
rated voltage 3~ 230 / 400V ± 10 % 265/460V±10 %
engine power kW 3.0 - 4.0 3.6 - 4.8
power consumption A 10,7/6,15 | 14,3/8,2 18,5/10,7 | 21,0/12,0
number of revolutions at least-1 1450 1740
Average sound pressure level dB(A) 75 77
Max weight kg 104-106

Other technical data on request

V-KTA 80/1 pressure-vacuum pumps IE3 motors Technical data

vacuum suction air bar 0 0 -0,4 -0,5 -0,6 0 -0,4 -0,5 -0,6
overpressure compressed air bar 0 +0,4 +0,5
suction air volume flow m³/h (50 Hz) 70,0 68,0 58,5 55,0 50,8 67,0 57,6 54,0 49,5
m³/h (60 Hz) 82,6 80,2 69,0 64,9 60,0 79,0 68,0 63,7 57,4
Compressed air volume flow m³/h (50 Hz) 68,5 64,4 52,7 49,4 46,0 63,5 51,8 48,6 45,0
m³/h (60 Hz) 80,8 76,0 62,2 58,3 54,3 74,9 61,1 57,3 53,1
engine power kW (50Hz) 3,0 4,0
kW (60Hz) 3,6 4,8

Other technical data on request

V-KTA 80/2 pressure-vacuum pumps IE3 motors Technical data

vacuum suction air bar 0 0 -0,4 -0,5 -0,6 0 -0,4 -0,5 -0,6
overpressure compressed air bar 0 +0,4 +0,5
suction air volume flow m³/h (50 Hz) 50,5 48,7 39,6 36,3 32,0 48,0 38,8 35,4 31,1
m³/h (60 Hz) 60,0 57,5 46,7 42,8 37,8 56,6 45,8 41,8 36,7
Compressed air volume flow m³/h (50 Hz) 73,0 69,2 58,5 55,6 53,0 68,2 57,3 54,6 52,0
m³/h (60 Hz) 86,1 81,7 69,0 65,6 62,5 80,5 67,6 64,4 61,4
engine power kW (50Hz) 3,0 4,0 3,0 4,0
kW (60Hz) 3,6 4,8

Other technical data on request

V-KTA 80/3 pressure-vacuum pumps IE3 motors Technical data

vacuum suction air bar 0 -0,4 -0,5 -0,6 0 -0,4 -0,5 -0,6
overpressure compressed air bar +0,6 +0,4 +0,7
suction air volume flow m³/h (50 Hz) 70,5 61,,8 58,3 53,7 69,5 60,8 57,2 52,5
m³/h (60 Hz) 83,2 72,9 68,8 63,4 82,1 71,7 67,5 62,0
Compressed air volume flow m³/h (50 Hz) 51,5 38,6 35,0 31,2 50,4 37,5 33,7 30,0
m³/h (60 Hz) 60,8 45,5 41,3 36,8 59,5 44,3 39,8 35,4
engine power kW (50Hz) 3,0 4,0 3,0 4,0
kW (60Hz) 4,8

Other technical data on request

V-KTA 80 pressure-vacuum pumps Other voltages

U [V] 50Hz 60Hz
ll Δ ll Υ ¦Δ ¦ Υ ll Δ ll Υ ¦Δ ¦ Υ
V-KTA 80 xx Vx 200 346 200 230 400
V-KTA 80 xx Sx 200 230 400 230 460
V-KTA 80 xx Ux 330 380 660 220 380 440
V-KTA 80 xx Tx 200 400 690 230 400 460

Other technical data on request

    *Required fields