FPZ

Home/FPZ
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 74 m³/h 89 m³/h
    Pressure difference - vacuum / pressure 120 / 130 mbar 120 / 120 mbar
    Motor Rating 0.37 kW 0.43 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection.
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 137 m³/h 166 m³/h
    Pressure difference - vacuum / pressure 140 - 225 / 140 - 250 mbar 120 - 250 / 120 - 250 mbar
    Motor Rating 0.75 - 1.5 kW 0.9 - 1.75 kW
  • TD Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 139 m³/h 168 m³/h
    Pressure difference - vacuum / pressure 175-275 / 175-400 mbar 140-300 / 140-350 mbar
    Motor Rating 1.1 - 2.2 kW 1.3 - 2.55 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 219 m³/h 265 m³/h
    Pressure difference - vacuum / pressure 130 - 240 / 130-300 mbar 100 - 275 / 100-350 mbar
    Motor Rating 1.1 -3.0 kW 1.3 - 3.45 kW
  • TD Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 215 m³/h 259 m³/h
    Pressure difference - vacuum / pressure 240-400 / 240-475 mbar 210-400 / 210-425 mbar
    Motor Rating 2.2 - 4.0 kW 2.55 - 4.6 kW
  • TS Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 409 m³/h 493 m³/h
    Pressure difference - vacuum / pressure 115-225 / 115-250 mbar 90-210 / 90-210 mbar
    Motor Rating 2.2 - 4.0 kW 2.55 - 4.6 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection.
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 304 m³/h 366 m³/h
    Pressure difference - vacuum / pressure 180-270/ 180-340 mbar 150-325 / 150-220 mbar
    Motor Rating 2.2-4.0 kW 2.55-4.6 kW
  • TD Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 312 m³/h 376 m³/h
    Pressure difference - vacuum / pressure 275-400 / 275-550 mbar 225-400 / 225-525 mbar
    Motor Rating 4.0 - 7.5 kW 4.6 - 8.7 kW
  • TS Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 562 m³/h 679 m³/h
    Pressure difference - vacuum / pressure 130-250 / 130-300 mbar 100-250 / 100-275 mbar
    Motor Rating 4.0 - 7.5 kW 4.6 - 8.7 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection.
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 414 m³/h 499 m³/h
    Pressure difference - vacuum / pressure 130-325 / 130-400 mbar 100-375 / 100-375 mbar
    Motor Rating 2.2-5.5 kW 2.55-6.3 kW
  • TD Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 416  m³/h 502  m³/h
    Pressure difference - vacuum / pressure 325-425 / 325-575 mbar 275-450 / 275-650 mbar
    Motor Rating 5.5 - 9.2 kW 6.3 - 12.7 kW
  • TS Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 827 m³/h 998 m³/h
    Pressure difference - vacuum / pressure 150-300 / 150-350 mbar 110-300 / 110-300 mbar
    Motor Rating 5.5 - 11.0 kW 6.3 - 12.7 kW
  • MD Blowers offer single impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 181 m³/h 218 m³/h
    Pressure difference - vacuum / pressure 275-450 / 275-650 mbar 215-450 / 215-650 mbar
    Motor Rating 2.2 - 5.5 kW 2.55 - 6.3 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection.
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 536 m³/h 647 m³/h
    Pressure difference - vacuum / pressure 125-350 / 125-450 mbar 100-375 / 100-450 mbar
    Motor Rating 3.0 - 9.2 kW 3.45 - 10.6 kW
  • TD Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 518  m³/h 625  m³/h
    Pressure difference - vacuum / pressure 235-450 / 235-550 mbar 180-475 / 180-490 mbar
    Motor Rating 5.5 - 15.0 kW 6.3 - 17.4 kW
  • TS Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 1006 m³/h 1214 m³/h
    Pressure difference - vacuum / pressure 100-325 / 100-380 mbar 60-325 / 60-325 mbar
    Motor Rating 5.5 - 15.0 kW 6.3 - 17.4 kW
  • MD Blowers offer single impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 236 m³/h 285 m³/h
    Pressure difference - vacuum / pressure 250-450 / 250-650 mbar 180-450 / 180-650 mbar
    Motor Rating 3.0 - 7.5 kW 3.45 - 8.7 kW
  • MD Blowers offer single impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 310 m³/h 374 m³/h
    Pressure difference - vacuum / pressure 285-475 / 285-725 mbar 200-475 / 200/725 mbar
    Motor Rating 4.0 - 9.2 kW 4.6 - 10.6 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection.
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 663 m³/h 800 m³/h
    Pressure difference - vacuum / pressure 130-350 / 130-450 mbar 85-375 / 85-400 mbar
    Motor Rating 4 - 11 kW 4.6 - 12.7 kW
  • TD Blowers offer twin impeller - double stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Designation Worth
    Frequency 50 Hz 60 Hz
    Capacity 657  m³/h 793  m³/h
    Pressure difference - vacuum / pressure 300-450 / 300-650 mbar 240-475 / 240-650 mbar
    Motor Rating 9.2 - 18.5 kW 10.6 - 21.5 kW
Go to Top