MS Serie

  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 74 m³/h 89 m³/h
    Druckdifferenz - vakuum / druck 120 / 130 mbar 120 / 120 mbar
    Motorleistung 0,37 kW 0,43 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 137 m³/h 166 m³/h
    Druckdifferenz - vakuum / druck 140-225 / 140-250 mbar 120-250 / 120-250 mbar
    Motorleistung 0,75 - 1,5 kW 0,9 - 1,75 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 219 m³/h 265 m³/h
    Druckdifferenz - vakuum / druck 130-240 / 130-300 mbar 100-275 / 100-350 mbar
    Motorleistung 1.1 -3.0 kW 1.3 – 3.45 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 304 m³/h 366 m³/h
    Druckdifferenz - vakuum / druck 180-270/ 180-340 mbar 150-325 / 150-220 mbar
    Motorleistung 2,2-4,0 kW 2,55-4,6 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 414 m³/h 499 m³/h
    Druckdifferenz - vakuum / druck 130-325 / 130-400 mbar 100-375 / 100-375 mbar
    Motorleistung 2.2-5.5 kW 2,55-6,3 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 536 m³/h 647 m³/h
    Druckdifferenz - vakuum / druck 125-350 / 125-450 mbar 100-375 / 100-450 mbar
    Motorleistung 3,0 – 9,2 kW 3,45 – 10,6 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 663 m³/h 800 m³/h
    Druckdifferenz - vakuum / druck 130-350 / 130-450 mbar 85-375 / 85-400 mbar
    Motorleistung 4 - 11 kW 4,6 - 12,7 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 782 m³/h 944 m³/h
    Druckdifferenz - vakuum / druck 160-350 / 160-500 mbar 115-375 / 115-500 mbar
    Motorleistung 5,5 - 15,0 kW 6,3 - 17,4 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 915 m³/h 1105 m³/h
    Druckdifferenz - vakuum / druck 175-350 / 175-500 mbar 130-350 / 130-500 mbar
    Motorleistung 7,5 - 18,5 kW 8,7 - 21,5 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 1022 m³/h 1234 m³/h
    Druckdifferenz - vakuum / druck 150-325 / 150-425 mbar 100-350 / 100-375 mbar
    Motorleistung 9,2 - 18,5 kW 10,6 - 21,5 kW
  • MS Blowers offer single impeller - single stage, integral motor design versions, aluminum construction. Two-pole electric motors, single-phase and three phase asynchronous, insulation class F-Tropicalised and IP55 protection. 
    Bezeichnung Wert
    Frequenz 50 Hz 60 Hz
    Volumenstrom 477 m³/h 576 m³/h
    Druckdifferenz - vakuum / druck 150-250 / 150-325 mbar 100-300 / 100-300 mbar
    Motorleistung 4,0 – 7,5 kW 4,6 - 8,7 kW